Clinical Chemistry AACC Online Job Center
HOME HELP FEEDBACK SUBSCRIPTIONS ARCHIVE SEARCH TABLE OF CONTENTS
 QUICK SEARCH:   [advanced]


     


Clinical Chemistry 20: 424-427, 1974;
This Article
Right arrow Full Text (PDF)
Right arrow Submit an electronic Letter to
the Editor about this paper
Right arrow Alert me when this article is cited
Right arrow Alert me when eLetters are posted
Right arrow Alert me if a correction is posted
Services
Right arrow Email this article to a friend
Right arrow Similar articles in this journal
Right arrow Similar articles in PubMed
Right arrow Alert me to new issues of the journal
Right arrow Download to citation manager
Right arrow reprints & permissions
Citing Articles
Right arrow Citing Articles via Google Scholar
Google Scholar
Right arrow Articles by Neeley, W. E.
Right arrow Articles by Sing, H. C.
Right arrow Search for Related Content
PubMed
Right arrow PubMed Citation
Right arrow Articles by Neeley, W. E.
Right arrow Articles by Sing, H. C.

Clinical Chemistry, Vol 20, 424-427, Copyright © 1974 by the American Association for Clinical Chemistry

Design and Performance of a Miniaturized High-Speed Continuous-Flow Analyzer

William E. Neeley 1, Stephen C. Wardlaw 2, and Helen C. Sing 1

1 Division of Biochemistry, Walter Reed Army Institute of Research, Washington, D. C. 20012.
2 Department of Laboratory Medicine, Yale-New Haven Hospital, New Haven, Conn. 06510.

Design features and performance of a miniaturized high-speed continuous-flow analyzer are described. Special emphasis is made in the design towards a system that is free from the operational and mechanical complexities found in most of today’s advanced systems. Depending on the particular analyses, sample size varies from 3 to 25 µl and reagent consumption is less than 180 µl per sample. Analyses are performed under steady-state conditions at sampling rates of 150 samples per hour with a 2:1 or 3:1 sample-to-wash ratio. The marked reduction in sample size makes the system ideal for microanalyses, especially in the pediatric clinical laboratory, in small animal research, and in any other cases where small sample volume is especially important.


Key Words: glucose and total protein determinations as representative of results • pediatric chemistry • AutoAnalyzer

Submitted on December 5, 1973
Accepted on January 11, 1974







HOME HELP FEEDBACK SUBSCRIPTIONS ARCHIVE SEARCH TABLE OF CONTENTS
Copyright © 1974 by the American Association for Clinical Chemistry.