Clinical Chemistry Link to Randox Laboratories Web Site
HOME HELP FEEDBACK SUBSCRIPTIONS ARCHIVE SEARCH TABLE OF CONTENTS
 QUICK SEARCH:   [advanced]


     


Clinical Chemistry 21: 1396-1405, 1975;
This Article
Right arrow Full Text (PDF)
Right arrow Submit an electronic Letter to
the Editor about this paper
Right arrow Alert me when this article is cited
Right arrow Alert me when eLetters are posted
Right arrow Alert me if a correction is posted
Services
Right arrow Email this article to a friend
Right arrow Similar articles in this journal
Right arrow Similar articles in PubMed
Right arrow Alert me to new issues of the journal
Right arrow Download to citation manager
Right arrow reprints & permissions
Citing Articles
Right arrow Citing Articles via HighWire
Right arrow Citing Articles via Google Scholar
Google Scholar
Right arrow Articles by Cembrowski, G. S.
Right arrow Articles by Toren, E. C.
Right arrow Search for Related Content
PubMed
Right arrow PubMed Citation
Right arrow Articles by Cembrowski, G. S.
Right arrow Articles by Toren, E. C., Jr.

Clinical Chemistry, Vol 21, 1396-1405, Copyright © 1975 by the American Association for Clinical Chemistry

Trend Detection in Control Data: Optimization and Interpretation of Trigg's Technique for Trend Analysis

George S. Cembrowski 1, James O. Westgard 1, Arthur A. Eggert 1, and E. Clifford Toren Jr. 1

1 Departments of Medicine, Pathology, and the Clinical Laboratories, University of Wisconsin Center for Health Sciences, 1300 University Ave., Madison, Wis. 53706.

A method for trend detection, Trigg's technique [Oper. Res. Q. 15, 271 (1964)], has been investigated for use in monitoring trends in control data produced by multitest continuous-flow analyzers. Simulated trend data were used to optimize the method. Actual control data were analyzed retrospectively to determine the frequency of trends and the accuracy of several parameters obtained from Trigg's method. The prospective use of the technique has successfully uncovered important trends. Criteria for the interpretation of the Trigg's trend data are suggested and an algorithm for the computer implementation of Trigg’s calculations is included.


Key Words: statistics • Levey—Jennings plot • cusum values • continuous-flow analysis • quality control • computers

Submitted on April 7, 1975
Accepted on May 17, 1975




The following articles in journals at HighWire Press have cited this article:


Home page
Clin. Chem.Home page
A. S. Neubauer
The EWMA control chart: properties and comparison with other quality-control procedures by computer simulation
Clin. Chem., April 1, 1997; 43(4): 594 - 601.
[Abstract] [Full Text] [PDF]




HOME HELP FEEDBACK SUBSCRIPTIONS ARCHIVE SEARCH TABLE OF CONTENTS
Copyright © 1975 by the American Association for Clinical Chemistry.