Clinical Chemistry AACC Online Job Center
HOME HELP FEEDBACK SUBSCRIPTIONS ARCHIVE SEARCH TABLE OF CONTENTS
 QUICK SEARCH:   [advanced]


     


Clinical Chemistry 21: 1427-1429, 1975;
This Article
Right arrow Full Text (PDF)
Right arrow Submit an electronic Letter to
the Editor about this paper
Right arrow Alert me when this article is cited
Right arrow Alert me when eLetters are posted
Right arrow Alert me if a correction is posted
Services
Right arrow Email this article to a friend
Right arrow Similar articles in this journal
Right arrow Similar articles in PubMed
Right arrow Alert me to new issues of the journal
Right arrow Download to citation manager
Right arrow reprints & permissions
Citing Articles
Right arrow Citing Articles via Google Scholar
Google Scholar
Right arrow Articles by Slaunwhite, W. D.
Right arrow Articles by Kissinger, P. T.
Right arrow Search for Related Content
PubMed
Right arrow PubMed Citation
Right arrow Articles by Slaunwhite, W. D.
Right arrow Articles by Kissinger, P. T.

Clinical Chemistry, Vol 21, 1427-1429, Copyright © 1975 by the American Association for Clinical Chemistry

Colorimetric, Enzymatic, and Liquid-Chromatographic Methods for Serum Uric Acid Compared

W. David Slaunwhite 1, Lawrence A. Pachla 2, David C. Wenke 1, and Peter T. Kissinger 2

1 Erie County Laboratory, 462 Grider St., Buffalo, N. Y. 14215.
2 Department of Chemistry, Michigan State University, East Lansing, Mich. 48824.

Peter T. Kissinger, Department of Chemistry, Purdue University, West Lafayette, Ind. 47907.

We describe high-performance liquid chromatography in conjunction with electrochemical detection as a possible reference method for serum uric acid. Separation was effected on a column packed with "Vydac" strong anion-exchange resin, with use of a detection potential of +0.80 V vs. an Ag/AgCl reference electrode. Results were linearly related to concentration up to 1.0 g/liter, and no interferences were seen. Assay of human sera gave within-run and day-to-day coefficients of variation of 0.83% and 1.1%, respectively; analytical recoveries averaged 100%. Comparison of the new procedure (x) with the phosphotungstate and uricase methods (y) showed the following linear regression and correlation coefficients for results: y = 0.963x + 0.219 (r = 0.995), and y = 0.991x + 0.165 (r = 0.999), respectively. As compared to these methods, the procedure we describe is more accurate, because of the selective detection system based on retention time and redox potential. Samples can be analyzed at the rate of 20/h. No deproteinization is required.


Key Words: Intermethod comparison

Submitted on April 28, 1975
Accepted on May 27, 1975