Clinical Chemistry Link to Randox Laboratories Web Site
HOME HELP FEEDBACK SUBSCRIPTIONS ARCHIVE SEARCH TABLE OF CONTENTS
 QUICK SEARCH:   [advanced]


     


Clinical Chemistry 21: 1520-1522, 1975;
This Article
Right arrow Full Text (PDF)
Right arrow Submit an electronic Letter to
the Editor about this paper
Right arrow Alert me when this article is cited
Right arrow Alert me when eLetters are posted
Right arrow Alert me if a correction is posted
Services
Right arrow Email this article to a friend
Right arrow Similar articles in this journal
Right arrow Similar articles in PubMed
Right arrow Alert me to new issues of the journal
Right arrow Download to citation manager
Right arrow reprints & permissions
Citing Articles
Right arrow Citing Articles via Google Scholar
Google Scholar
Right arrow Articles by Silbert, C. K.
Right arrow Articles by Sawin, C. T.
Right arrow Search for Related Content
PubMed
Right arrow PubMed Citation
Right arrow Articles by Silbert, C. K.
Right arrow Articles by Sawin, C. T.

Clinical Chemistry, Vol 21, 1520-1522, Copyright © 1975 by the American Association for Clinical Chemistry

Double-Antibody Radioimmunoassay of Serum Insulin: Effect of Use of Hormone-Depleted Human Serum

Cynthia K. Silbert 1 and Clark T. Sawin 1

1 Medical Service, Boston Veterans Administration Hospital; and the Departments of Medicine of Boston University and Tufts University Schools of Medicine, Boston, Mass. 02130.

Human serum can be depleted of insulin and growth hormone by treatment with dextran-coated charcoal or by dialysis, or both. Inclusion of such hormone-depleted serum in the standard curve of a double-antibody radioimmunoassay for immunoreactive insulin more nearly mimics the conditions under which an unknown human serum sample is assayed. Compared to the usual standard curve in which serum albumin is the only protein, the addition of hormone-depleted serum can cause an increase (by an average 64% under the conditions we used) in the absolute value for apparent insulin in serum. The effect of hormone-depleted serum should be tested in the standard curves of double-antibody radioimmunoassays and included routinely in these standard curves if it changes the results. When used in conjunction with an eventual reference standard for human insulin, this modification of the insulin assay may make the measured values of human serum insulin from different laboratories more comparable.

Submitted on April 11, 1975
Accepted on June 4, 1975







HOME HELP FEEDBACK SUBSCRIPTIONS ARCHIVE SEARCH TABLE OF CONTENTS
Copyright © 1975 by the American Association for Clinical Chemistry.