Clinical Chemistry Link to Randox Laboratories Web Site
HOME HELP FEEDBACK SUBSCRIPTIONS ARCHIVE SEARCH TABLE OF CONTENTS
 QUICK SEARCH:   [advanced]


     


Clinical Chemistry 21: 1721-1724, 1975;
This Article
Right arrow Full Text (PDF)
Right arrow Submit an electronic Letter to
the Editor about this paper
Right arrow Alert me when this article is cited
Right arrow Alert me when eLetters are posted
Right arrow Alert me if a correction is posted
Services
Right arrow Email this article to a friend
Right arrow Similar articles in this journal
Right arrow Similar articles in PubMed
Right arrow Alert me to new issues of the journal
Right arrow Download to citation manager
Right arrow reprints & permissions
Citing Articles
Right arrow Citing Articles via HighWire
Right arrow Citing Articles via Google Scholar
Google Scholar
Right arrow Articles by Marton, L. J.
Right arrow Articles by Lee, P. L. Y.
Right arrow Search for Related Content
PubMed
Right arrow PubMed Citation
Right arrow Articles by Marton, L. J.
Right arrow Articles by Lee, P. L. Y.

Clinical Chemistry, Vol 21, 1721-1724, Copyright © 1975 by the American Association for Clinical Chemistry

More Sensitive Automated Detection of Polyamines in Physiological Fluids and Tissue Extracts with o-Phthalaldehyde

Laurence J. Marton 1 and Patrick L. Y. Lee 2

1 Naffziger Laboratories for Neurosurgical Research, Department of Neurological Surgery, University of California, San Francisco, Calif. 94143.Department of Laboratory Medicine, University of California, San Francisco, Calif. 94143.
2 Durrum Instrument Corp., Palo Alto, Calif. 94303.

o-Phthalaldehyde reacts with primary amines to form an intensely blue-fluorescing product. Replacing ninhydrin with this compound in our automated high-pressure liquid-chromatographic technique for determination of polyamines, we achieved a 6-to 10-fold increase in sensitivity. Linearity and reproducibility are excellent, and the method is shown to be applicable to analysis of physiological fluids and of tissue extracts.


Key Words: cancer • high-pressure liquid chromatography

Submitted on July 7, 1975
Accepted on August 6, 1975




The following articles in journals at HighWire Press have cited this article:


Home page
ScienceHome page
G. Lux, L. Marton, and S. Baylin
Ornithine decarboxylase is important in intestinal mucosal maturation and recovery from injury in rats
Science, October 10, 1980; 210(4466): 195 - 198.
[Abstract] [PDF]




HOME HELP FEEDBACK SUBSCRIPTIONS ARCHIVE SEARCH TABLE OF CONTENTS
Copyright © 1975 by the American Association for Clinical Chemistry.