Clinical Chemistry Link to Randox Laboratories Web Site
HOME HELP FEEDBACK SUBSCRIPTIONS ARCHIVE SEARCH TABLE OF CONTENTS
 QUICK SEARCH:   [advanced]


     


Clinical Chemistry 23: 270-274, 1977;
This Article
Right arrow Full Text (PDF)
Right arrow Submit an electronic Letter to
the Editor about this paper
Right arrow Alert me when this article is cited
Right arrow Alert me when eLetters are posted
Right arrow Alert me if a correction is posted
Right arrow Citation Map
Services
Right arrow Email this article to a friend
Right arrow Similar articles in this journal
Right arrow Similar articles in PubMed
Right arrow Alert me to new issues of the journal
Right arrow Download to citation manager
Right arrow reprints & permissions
Citing Articles
Right arrow Citing Articles via HighWire
Right arrow Citing Articles via Google Scholar
Google Scholar
Right arrow Articles by Blumberg, W. E.
Right arrow Articles by Zuckerman, D. M.
Right arrow Search for Related Content
PubMed
Right arrow PubMed Citation
Right arrow Articles by Blumberg, W. E.
Right arrow Articles by Zuckerman, D. M.

Clinical Chemistry, Vol 23, 270-274, Copyright © 1977 by American Association for Clinical Chemistry

The hematofluorometer

WE Blumberg, J Eisinger, AA Lamola and DM Zuckerman

A portable filter fluorometer, the hematofluorometer--which utilizes "front face" optics, internal standards, and digital computation capabilities--has been specifically designed for the rapid (approximately 5 s) assay of erythrocyte zinc protoporphyrin in unprocessed blood. A small (unmeasured) drop of blood, such as is obtained from a finger puncture, is placed on disposable cover slip and inserted in the sample holder of the instrument. The operator pushes the holder of the instrument. The operator pushes the holder, which also holds the permanent blank and standard, into the instrument. Zinc protoporphyrin concentration is automatically and instantaneously computed and the value is displayed on a digital readout as micrograms of zinc protoporphyrin per deciliter of blood for some standard hematocrit. No calibration adjustment need be performed by the operator. The hematofluorometer is designed for "field" use as well as for laboratory assays.


The following articles in journals at HighWire Press have cited this article:


Home page
J. Nutr.Home page
B. Shell-Duncan and T. McDade
Use of Combined Measures from Capillary Blood to Assess Iron Deficiency in Rural Kenyan Children
J. Nutr., February 1, 2004; 134(2): 384 - 387.
[Abstract] [Full Text] [PDF]


Home page
Am. J. Clin. Nutr.Home page
Z. Mei, I. Parvanta, M. E Cogswell, E. W Gunter, and L. M Grummer-Strawn
Erythrocyte protoporphyrin or hemoglobin: which is a better screening test for iron deficiency in children and women?
Am. J. Clinical Nutrition, May 1, 2003; 77(5): 1229 - 1233.
[Abstract] [Full Text] [PDF]


Home page
Clin. Chem.Home page
T. M. Ambrose, M. Al-Lozi, and M. G. Scott
Bone Lead Concentrations Assessed by in Vivo X-Ray Fluorescence
Clin. Chem., August 1, 2000; 46(8): 1171 - 1178.
[Abstract] [Full Text] [PDF]


Home page
Clin. Chem.Home page
R. F. Labbe, A. Dewanji, and K. McLaughlin
Observations on the Zinc Protoporphyrin/Heme Ratio in Whole Blood
Clin. Chem., January 1, 1999; 45(1): 146 - 148.
[Full Text] [PDF]


Home page
Hum Exp ToxicolHome page
J. Calderon-Salinas, C. Hernandez-Luna, B. Valdez-Anaya, M. Maldonado-Vega, and A. Lopez-Miranda
Evolution of lead toxicity in a population of children
Human and Experimental Toxicology, May 1, 1996; 15(5): 376 - 382.
[Abstract] [PDF]


Home page
Hum Exp ToxicolHome page
J. Calderon-Salinas, B. Valdez-Anaya, Mazuniga-Charles, and A. Albores-Medina
Lead exposure in a population of Mexican children
Human and Experimental Toxicology, April 1, 1996; 15(4): 305 - 311.
[Abstract] [PDF]


Home page
ScienceHome page
J. Valciukas, R Lilis, A Fischbein, I. Selikoff, J Eisinger, and W. Blumberg
Central nervous system dysfunction due to lead exposure
Science, August 4, 1978; 201(4354): 465 - 467.
[Abstract] [PDF]




HOME HELP FEEDBACK SUBSCRIPTIONS ARCHIVE SEARCH TABLE OF CONTENTS
Copyright © 1977 by the American Association for Clinical Chemistry.