Clinical Chemistry AACC Online Job Center
HOME HELP FEEDBACK SUBSCRIPTIONS ARCHIVE SEARCH TABLE OF CONTENTS
 QUICK SEARCH:   [advanced]


     


Clinical Chemistry 23: 1230-1237, 1977;
This Article
Right arrow Full Text (PDF)
Right arrow Submit an electronic Letter to
the Editor about this paper
Right arrow Alert me when this article is cited
Right arrow Alert me when eLetters are posted
Right arrow Alert me if a correction is posted
Services
Right arrow Email this article to a friend
Right arrow Similar articles in this journal
Right arrow Similar articles in PubMed
Right arrow Alert me to new issues of the journal
Right arrow Download to citation manager
Right arrow reprints & permissions
Citing Articles
Right arrow Citing Articles via Google Scholar
Google Scholar
Right arrow Articles by Pardue, H. L.
Right arrow Articles by Rubesch, M. A.
Right arrow Search for Related Content
PubMed
Right arrow PubMed Citation
Right arrow Articles by Pardue, H. L.
Right arrow Articles by Rubesch, M. A.

Clinical Chemistry, Vol 23, 1230-1237, Copyright © 1977 by American Association for Clinical Chemistry

Evaluation of a discrete samples/stopped-flow mixer system for equilibrium and kinetic analyses

HL Pardue, HT Gaw, GE Mieling, VL Mathews, DM Fast and MA Rubesch

This paper describes the evaluation of a system for computer-controlled discrete sampling and stopped-flow mixing for equilibrium and kinetic determinations of several sorts of analytes in human serum. The instrumental system features a wash-out sampling system that permits rapid change-over from one sample and (or) reagent type to another, and a mixing-measurement system that can provide reliable data as soon as 10 ms after reagent and sample are mixed. Examples discussed include equilibrium procedures for glucose and cholesterol, slow kinetic procedures for glucose and lactate dehydrogenase, and a fast kinetic method for thiocyanate. The regression equation for all stopped-flow results (n = 114) vs. results by conventional methods is y = (103 +/- 0.01)x - (0.016 +/- 0.019) for numerical values of y between 0.3 and 3.0. The correlation coefficient for these data was 0.991. These results demonstrate that the stopped-flow method is a viable analytical approach for equilibrium, slow kinetic, and fast kinetic determinations that require measurement times shorter than 0.1 s.