Clinical Chemistry Link to Randox Laboratories Web Site
HOME HELP FEEDBACK SUBSCRIPTIONS ARCHIVE SEARCH TABLE OF CONTENTS
 QUICK SEARCH:   [advanced]


     


Clinical Chemistry 24: 1100-1104, 1978;
This Article
Right arrow Full Text (PDF)
Right arrow Submit an electronic Letter to
the Editor about this paper
Right arrow Alert me when this article is cited
Right arrow Alert me when eLetters are posted
Right arrow Alert me if a correction is posted
Services
Right arrow Email this article to a friend
Right arrow Similar articles in this journal
Right arrow Similar articles in PubMed
Right arrow Alert me to new issues of the journal
Right arrow Download to citation manager
Right arrow reprints & permissions
Citing Articles
Right arrow Citing Articles via Google Scholar
Google Scholar
Right arrow Articles by Liedtke, R. J.
Right arrow Articles by Busby, B.
Right arrow Search for Related Content
PubMed
Right arrow PubMed Citation
Right arrow Articles by Liedtke, R. J.
Right arrow Articles by Busby, B.

Clinical Chemistry, Vol 24, 1100-1104, Copyright © 1978 by American Association for Clinical Chemistry

125I-radioimmunoassay for unconjugated estriol in serum of pregnant women

RJ Liedtke, JP Greaves Jr, JD Batjer and B Busby

An 125I-radioimmunoassay is described which measures unconjugated estriol in the serum of pregnant women. Estriol is extracted into ethyl acetate/hexane, an aliquot is evaporated, and the residue is redissolved in phosphate buffer. The sample is incubated with tracer and antibody at 37 degrees C for 15 min and then at 4 degrees C for 1 h and 45 min. The antibody-bound fraction is then precipitated with polyethylene glycol and isolated by centrifugation. Because the antigen- antibody complex is stable in the presence of polyethylene glycol, the separation steps are not influenced by timing. Extraction recovery of 3H-labeled estriol added to a pool of sera from pregnant women averaged 96.7% (SD = 1.3, n = 10). Estriol-supplemented (5, 10, and 20 microgram/liter) serum from men, carried through the entire procedure, showed analytical recovery ranging from 94 to 106%. Structurally analogous steroids normally present in serum of pregnant women exhibit negligible cross reactivity. Day-to-day precision (CV) is 13.3% (3.1 microgram/liter), 6.4% (7.6 microgram/liter), and 5.6% (21.4 microgram/liter) for n = 21. The current reagent cost (about 17 cents per tube), and a total procedural time, including counting, of 5.5 h make this an acceptable assay for routine use.





HOME HELP FEEDBACK SUBSCRIPTIONS ARCHIVE SEARCH TABLE OF CONTENTS
Copyright © 1978 by the American Association for Clinical Chemistry.