Clinical Chemistry AACC Online Job Center
HOME HELP FEEDBACK SUBSCRIPTIONS ARCHIVE SEARCH TABLE OF CONTENTS
 QUICK SEARCH:   [advanced]


     


Clinical Chemistry 24: 1468-1472, 1978;
This Article
Right arrow Full Text (PDF)
Right arrow Submit an electronic Letter to
the Editor about this paper
Right arrow Alert me when this article is cited
Right arrow Alert me when eLetters are posted
Right arrow Alert me if a correction is posted
Services
Right arrow Email this article to a friend
Right arrow Similar articles in this journal
Right arrow Similar articles in PubMed
Right arrow Alert me to new issues of the journal
Right arrow Download to citation manager
Right arrow reprints & permissions
Citing Articles
Right arrow Citing Articles via HighWire
Right arrow Citing Articles via Google Scholar
Google Scholar
Right arrow Articles by Connolly, T. M.
Right arrow Articles by Vecsei, P.
Right arrow Search for Related Content
PubMed
Right arrow PubMed Citation
Right arrow Articles by Connolly, T. M.
Right arrow Articles by Vecsei, P.

Clinical Chemistry, Vol 24, 1468-1472, Copyright © 1978 by American Association for Clinical Chemistry

Simple radioimmunoassay of cortisol in diluted samples of human plasma

TM Connolly and P Vecsei

We describe a simple radioimmunoassay of plasma cortisol, which can be performed in 3 h and which requires no purification, heating, or refrigeration steps. The plasma proteins are inhibited through direct competition between them and the antiserum at room temperature, at which the antiserum's affinity exceeds that of the binding proteins. Plasma, diluted with water, is incubated for 3 h at room temperature with [3H]cortisol and the antiserum. We compared results with those by the usual extraction method. The correlation between methods on evaluating normal samples with one antiserum. We compared results with those by the usual extraction method. The correlation between methods on evaluating normal samples with one antiserum was r = 0.954 (P less than 0.001), and the slope was 0.661. With three other antisera it was r = 0.922 (P less than 0.001) and slope 0.644. Plasmas with abnormal protein concentrations (i.e., from preganant women, and after corticotropin administration), tested to examine the validity of the method for routine use, and to define the role of the protein carriers, showed r = 0.859 (P less than 0.001) and slope 0.726 for the four antisera used. Additional samples, assayed with diluted standards plus stripped plasma, showed a correlation with the usual extraction method of r = 0.945 (P less than 0.001) and slope 1.026.


The following articles in journals at HighWire Press have cited this article:


Home page
J. Clin. Endocrinol. Metab.Home page
J. Majnik, A. Patocs, K. Balogh, M. Toth, P. Gergics, A. Szappanos, A. Mondok, G. Borgulya, P. Panczel, Z. Prohaszka, et al.
Overrepresentation of the N363S Variant of the Glucocorticoid Receptor Gene in Patients with Bilateral Adrenal Incidentalomas
J. Clin. Endocrinol. Metab., July 1, 2006; 91(7): 2796 - 2799.
[Abstract] [Full Text] [PDF]




HOME HELP FEEDBACK SUBSCRIPTIONS ARCHIVE SEARCH TABLE OF CONTENTS
Copyright © 1978 by the American Association for Clinical Chemistry.