Clinical Chemistry 25: 230-234, 1979;
This Article
Right arrow Full Text (PDF)
Right arrow Submit an electronic Letter to
the Editor about this paper
Right arrow Alert me when this article is cited
Right arrow Alert me when eLetters are posted
Right arrow Alert me if a correction is posted
Services
Right arrow Email this article to a friend
Right arrow Similar articles in this journal
Right arrow Similar articles in PubMed
Right arrow Alert me to new issues of the journal
Right arrow Download to citation manager
Right arrow reprints & permissions
Citing Articles
Right arrow Citing Articles via Google Scholar
Google Scholar
Right arrow Articles by Goutte-Coussieu, C.
Right arrow Articles by Jayle, M. F.
Right arrow Search for Related Content
PubMed
Right arrow PubMed Citation
Right arrow Articles by Goutte-Coussieu, C.
Right arrow Articles by Jayle, M. F.

Clinical Chemistry, Vol 25, 230-234, Copyright © 1979 by American Association for Clinical Chemistry

Rapid fluorometry of estrogens in nonpregnancy urine, with use of chloroform extraction and purification by anion-exchange chromatography

C Goutte-Coussieu, G Habrioux, D Eichenberger and MF Jayle

We describe a new method of extraction and purification of estrogens in low concentration in urine, involving a rapid enzymic hydrolysis of a 10-mL sample, automatic extraction (in a tube) with CHCl3/ethyl acetate, purification by chromatography on a disposable "mini-column" of AG 1-X2, and fluorometry by continuous flow according to Itrich's procedure [Acta Endocrinol. (Copenhagen) 35, 34 (1960)]. Conditions of hydrolysis, extraction, and purification were studied. Within-day precision (CV) was 7.5%, the mean between-day precision 8.5%. The sensitivity was 6 microgram of total estrogens per liter of urine. The specificity was assessed particularly by comparison with the results obtained by Scholler et al. [Acta Endocrinol. (Copenhagen) 57, suppl. 107 (1966)] and by gas-chromatography-mass-spectrometry. The normal limits as calculated by this technique were identical to values reported by others. The technique is rapid; results are obtained in 3 h. It is quite suitable for routine determinations: 100 assays can be done by a team of three technicians in one working day.