Clinical Chemistry Link to Randox Laboratories Web Site
HOME HELP FEEDBACK SUBSCRIPTIONS ARCHIVE SEARCH TABLE OF CONTENTS
 QUICK SEARCH:   [advanced]


     


Clinical Chemistry 25: 305-308, 1979;
This Article
Right arrow Full Text (PDF)
Right arrow Submit an electronic Letter to
the Editor about this paper
Right arrow Alert me when this article is cited
Right arrow Alert me when eLetters are posted
Right arrow Alert me if a correction is posted
Services
Right arrow Email this article to a friend
Right arrow Similar articles in this journal
Right arrow Similar articles in PubMed
Right arrow Alert me to new issues of the journal
Right arrow Download to citation manager
Right arrow reprints & permissions
Citing Articles
Right arrow Citing Articles via Google Scholar
Google Scholar
Right arrow Articles by Bergdahl, B.
Right arrow Articles by Bertler, A.
Right arrow Search for Related Content
PubMed
Right arrow PubMed Citation
Right arrow Articles by Bergdahl, B.
Right arrow Articles by Bertler, A.

Clinical Chemistry, Vol 25, 305-308, Copyright © 1979 by American Association for Clinical Chemistry

Four kits for plasma digoxin radioimmunoassay compared

B Bergdahl, L Molin, L Lindwall, G Dahlstrom, IL Scherling and A Bertler

We evaluated four commercial radioimmunoassay kits for digoxin. We assayed a standard plasma containing digoxin, 2.0 microgram/L, and samples from patients receiving digoxin, with use of the kits and of a bioassay, the 86Rb-uptake inhibition technique. Intra-assay precisions differed significantly. Computer-calculated 95% confidence intervals for the radioimmunoassays averaged 0.4 to 0.6 microgram/L at the proposed toxic threshold of 2.0 microgram/L; the corresponding value of the 86Rb assay was 0.75 microgram/L. Digoxin in the standard plasma was overestimated with three of the kits (means: 2.40, 2.56, and 2.59 microgram/L) but was assayed accurately by the 86Rb technique and by one kit. This same kit gave a significantly lower mean (1.07 microgram/L) for the patients' samples then did the other three kits (1.32, 1.49, and 1.29 microgram/L), two of which also differed significantly in accuracy. The 86Rb assay measured glycoside activity corresponding to a mean digoxin concentration of 1.35 microgram/L. We conclude that the relatively low precision of digoxin assay and the variations in accuracy between kits from various vendors apparently deserve continual attention.





HOME HELP FEEDBACK SUBSCRIPTIONS ARCHIVE SEARCH TABLE OF CONTENTS
Copyright © 1979 by the American Association for Clinical Chemistry.