Clinical Chemistry Link to Randox Laboratories Web Site
HOME HELP FEEDBACK SUBSCRIPTIONS ARCHIVE SEARCH TABLE OF CONTENTS
 QUICK SEARCH:   [advanced]


     


Clinical Chemistry 26: 1480-1483, 1980;
This Article
Right arrow Full Text (PDF)
Right arrow Submit an electronic Letter to
the Editor about this paper
Right arrow Alert me when this article is cited
Right arrow Alert me when eLetters are posted
Right arrow Alert me if a correction is posted
Services
Right arrow Email this article to a friend
Right arrow Similar articles in this journal
Right arrow Similar articles in PubMed
Right arrow Alert me to new issues of the journal
Right arrow Download to citation manager
Right arrow reprints & permissions
Citing Articles
Right arrow Citing Articles via Google Scholar
Google Scholar
Right arrow Articles by Chow, F.
Right arrow Articles by Karmen, A.
Right arrow Search for Related Content
PubMed
Right arrow PubMed Citation
Right arrow Articles by Chow, F.
Right arrow Articles by Karmen, A.

Clinical Chemistry, Vol 26, 1480-1483, Copyright © 1980 by American Association for Clinical Chemistry

Specific detection of primary amines in the effluent of a gas- chromatographic column by on-line measurement of fluorescence

F Chow and A Karmen

Compounds with primary amino groups react with o-phthalaldehyde in solution to yield highly fluorescent products. This reaction is now in wide use for detecting amino acids and amines in liquid-chromatography effluents. We report here a method for using o-phthalaldehyde to detect primary amines in the effluent of a gas-liquid-chromatographic column. The effluent gas, nominally 20 mL/min, is delivered to a scrubber consisting of a small-bore, simulated capillary chromatographic column that is simultaneously supplied with 1 mL/min of the reagent solution. The liquid effluent of the scrubber, separated from the gas, is drawn through the flow cell of a fluorometer. Short-chain amines and ammonia were quantitatively scrubbed. The response of the fluorometer was directly proportional to the number of nanomoles injected into the column. Less than a nanomole of amine was detectable. Comparison of results with those from a hydrogen flame-ionization detector showed minimal additional peak broadening or compromise of resolution. These results demonstrate the feasibility of using highly specific, as well as sensitive, liquid-chromatographic detection methods for gas-liquid chromatography.