Clinical Chemistry Link to Randox Laboratories Web Site
HOME HELP FEEDBACK SUBSCRIPTIONS ARCHIVE SEARCH TABLE OF CONTENTS
 QUICK SEARCH:   [advanced]


     


Clinical Chemistry 26: 1666-1671, 1980;
This Article
Right arrow Full Text (PDF)
Right arrow Submit an electronic Letter to
the Editor about this paper
Right arrow Alert me when this article is cited
Right arrow Alert me when eLetters are posted
Right arrow Alert me if a correction is posted
Services
Right arrow Email this article to a friend
Right arrow Similar articles in this journal
Right arrow Similar articles in PubMed
Right arrow Alert me to new issues of the journal
Right arrow Download to citation manager
Right arrow reprints & permissions
Citing Articles
Right arrow Citing Articles via HighWire
Right arrow Citing Articles via Google Scholar
Google Scholar
Right arrow Articles by Simon, M.
Right arrow Articles by Cuan, J.
Right arrow Search for Related Content
PubMed
Right arrow PubMed Citation
Right arrow Articles by Simon, M.
Right arrow Articles by Cuan, J.

Clinical Chemistry, Vol 26, 1666-1671, Copyright © 1980 by American Association for Clinical Chemistry

C-terminal parathyrin (parathyroid hormone) radioimmunoassay in serum with commercially available reagents

M Simon and J Cuan

We describe a sequential double-antibody assay for measuring C-terminal parathyrin in serum with commercially available reagents. Intact bovine hormone, used as a working standard, is iodinated by conventional Chloramine T procedures. The antibody affinity is characteristic of high affinity binding (1.4 to 1.6 x 10(10) L/mol of intact parathyrin). The antibody also cross reacts with a C-terminal parathyrin fragment (amino acids 53-84) but not with a synthetic N-terminal parathyrin fragment (amino acids 1-34). The assay thus also measures both a C- terminal fragment of parathyrin and the intact hormone. The detection limit (250 ng/L; 500 int. units/L) is below the reference interval for healthy adults (430-1860 ng/L; 860-3720 int. units/L). Several commonly recognized problems with iodinated parathyrin are eliminated and accuracy and precision of the procedures for standard preparation and calibration are improved. Overall CV (between-run imprecision) is 10- 17%. Analytical recovery is 80-90%, and C-terminal parathyrin measured in fresh sera and in sera stored for seven days at 30 degrees C is equivalent.


The following articles in journals at HighWire Press have cited this article:


Home page
Clin. Chem.Home page
C. Bieglmayer, G. Prager, and B. Niederle
Kinetic Analyses of Parathyroid Hormone Clearance as Measured by Three Rapid Immunoassays during Parathyroidectomy
Clin. Chem., October 1, 2002; 48(10): 1731 - 1738.
[Abstract] [Full Text] [PDF]




HOME HELP FEEDBACK SUBSCRIPTIONS ARCHIVE SEARCH TABLE OF CONTENTS
Copyright © 1980 by the American Association for Clinical Chemistry.