Clinical Chemistry AACC Online Job Center
HOME HELP FEEDBACK SUBSCRIPTIONS ARCHIVE SEARCH TABLE OF CONTENTS
 QUICK SEARCH:   [advanced]


     


Clinical Chemistry 26: 1821-1824, 1980;
This Article
Right arrow Full Text (PDF)
Right arrow Submit an electronic Letter to
the Editor about this paper
Right arrow Alert me when this article is cited
Right arrow Alert me when eLetters are posted
Right arrow Alert me if a correction is posted
Services
Right arrow Email this article to a friend
Right arrow Similar articles in this journal
Right arrow Similar articles in PubMed
Right arrow Alert me to new issues of the journal
Right arrow Download to citation manager
Right arrow reprints & permissions
Citing Articles
Right arrow Citing Articles via Google Scholar
Google Scholar
Right arrow Articles by Homburger, H. A.
Right arrow Articles by Jacob, G. L.
Right arrow Search for Related Content
PubMed
Right arrow PubMed Citation
Right arrow Articles by Homburger, H. A.
Right arrow Articles by Jacob, G. L.

Clinical Chemistry, Vol 26, 1821-1824, Copyright © 1980 by American Association for Clinical Chemistry

Radioimmunoassay of creatine kinase B-isoenzymes in serum of patients with azotemia, obstructive uropathy, or carcinoma of the prostate or bladder

HA Homburger, SA Miller and GL Jacob

We measured the concentrations of creatine kinase B-isoenzymes by radioimmunoassay in 271 serum specimens from patients with azotemia, benign prostatic hyperplasia, adenocarcinoma of the prostate, and transitional cell carcinoma of the bladder. There was no correlation between the concentrations of B-isoenzymes and creatinine in the sera of azotemic patients. Above-normal concentrations of B-isoenzymes were found in sera from three patients with acute renal failure, but in only two of 28 specimens from patients with chronic renal failure. Above- normal concentrations of B-isoenzymes also were found in sera from three of 18 patients with untreated carcinoma of the prostate, 10 of 25 patients with treated carcinoma, 20 of 135 patients with benign prostatic hyperplasia, and 10 of 33 patients and with transitional cell carcinoma of the bladder. An above-normal concentration of B-isoenzymes in serum has a low predictive value for adenocarcinoma of the prostate, was not a sensitive indicator of the presence of carcinoma, and was noted paradoxically in six patients with treated carcinoma who had normal acid phosphatase activities in serum. We conclude that routine measurement of B-isoenzymes is not useful to establish the diagnosis of adenocarcinoma of the prostate.





HOME HELP FEEDBACK SUBSCRIPTIONS ARCHIVE SEARCH TABLE OF CONTENTS
Copyright © 1980 by the American Association for Clinical Chemistry.