Clinical Chemistry AACC Online Job Center
HOME HELP FEEDBACK SUBSCRIPTIONS ARCHIVE SEARCH TABLE OF CONTENTS
 QUICK SEARCH:   [advanced]


     


Clinical Chemistry 27: 1186-1189, 1981;
This Article
Right arrow Full Text (PDF)
Right arrow Submit an electronic Letter to
the Editor about this paper
Right arrow Alert me when this article is cited
Right arrow Alert me when eLetters are posted
Right arrow Alert me if a correction is posted
Services
Right arrow Email this article to a friend
Right arrow Similar articles in this journal
Right arrow Similar articles in PubMed
Right arrow Alert me to new issues of the journal
Right arrow Download to citation manager
Right arrow reprints & permissions
Citing Articles
Right arrow Citing Articles via HighWire
Right arrow Citing Articles via Google Scholar
Google Scholar
Right arrow Articles by Heikkinen, R.
Right arrow Articles by Adlercreutz, H.
Right arrow Search for Related Content
PubMed
Right arrow PubMed Citation
Right arrow Articles by Heikkinen, R.
Right arrow Articles by Adlercreutz, H.

Clinical Chemistry, Vol 27, 1186-1189, Copyright © 1981 by American Association for Clinical Chemistry

Reversed-phase C18 cartridge for extraction of estrogens from urine and plasma

R Heikkinen, T Fotsis and H Adlercreutz

We describe a simple method for extraction of estrogens that is efficient over the whole polarity range of estrogen metabolites in urine and plasma. A small reversed-phase C18 cartridge (Sep-Pak C18, Waters Associates, Inc.) is used for this purpose. After application of the biological fluid, followed by an aqueous wash, estrogens are eluted in 3 mL of methanol. For urine the pH should be kept at 3 before the methanol elution. When estrogens are extracted from plasma, the steroid- protein interaction is counteracted by the presence of triethylammonium sulfate and D-norgestrel at pH 5. The recoveries of added 3H-labeled estrogens are essentially quantitative. The capacity of the column is high and estrogens can be extracted from large volumes of pregnancy urine without loss in the washing water. Because of the high flow rate (2 mL/min) and the small volume of methanol in which the estrogens are eluted, the whole procedure is convenient and rapid.


The following articles in journals at HighWire Press have cited this article:


Home page
J EndocrinolHome page
S A Cavigelli, S L Monfort, T K Whitney, Y S Mechref, M Novotny, and M K McClintock
Frequent serial fecal corticoid measures from rats reflect circadian and ovarian corticosterone rhythms
J. Endocrinol., January 1, 2005; 184(1): 153 - 163.
[Abstract] [Full Text] [PDF]




HOME HELP FEEDBACK SUBSCRIPTIONS ARCHIVE SEARCH TABLE OF CONTENTS
Copyright © 1981 by the American Association for Clinical Chemistry.