Clinical Chemistry Link to Randox Laboratories Web Site
HOME HELP FEEDBACK SUBSCRIPTIONS ARCHIVE SEARCH TABLE OF CONTENTS
 QUICK SEARCH:   [advanced]


     


Clinical Chemistry 27: 1438-1440, 1981;
This Article
Right arrow Full Text (PDF)
Right arrow Submit an electronic Letter to
the Editor about this paper
Right arrow Alert me when this article is cited
Right arrow Alert me when eLetters are posted
Right arrow Alert me if a correction is posted
Services
Right arrow Email this article to a friend
Right arrow Similar articles in this journal
Right arrow Similar articles in PubMed
Right arrow Alert me to new issues of the journal
Right arrow Download to citation manager
Right arrow reprints & permissions
Citing Articles
Right arrow Citing Articles via HighWire
Right arrow Citing Articles via Google Scholar
Google Scholar
Right arrow Articles by Weinstock, N.
Right arrow Articles by Uhlemann, M.
Right arrow Search for Related Content
PubMed
Right arrow PubMed Citation
Right arrow Articles by Weinstock, N.
Right arrow Articles by Uhlemann, M.

Clinical Chemistry, Vol 27, 1438-1440, Copyright © 1981 by American Association for Clinical Chemistry

Automated determination of copper in undiluted serum by atomic absorption spectroscopy

N Weinstock and M Uhlemann

An injection method has been adapted for the determination of copper concentration in untreated, undiluted serum by flame atomic absorption spectroscopy. Serum, 50 or 100 microliter, is automatically injected by a commercial microprobe system into a plastic cone connected to the capillary tube of the burner, at a rate of 240 samples per hour. The required sample volume is considerably decreased, and sensitivity is increased 20- to 40-fold. After 500 measurements we observed no memory effects, carryover, or clogging of the burner. We discuss common difficulties with calibration standards due to viscosity and other physicochemical interferences, and suggest the use of pooled human serum as a secondary standard. Within-run CV was 1.8%, the day-to-day CV 2.2%. Comparison with a dilution method gave a correlation coefficient exceeding 0.98.


The following articles in journals at HighWire Press have cited this article:


Home page
Am. J. Clin. Nutr.Home page
C. R Jonas, A. B Puckett, D. P Jones, D. P Griffith, E. E Szeszycki, G. F Bergman, C. E Furr, C. Tyre, J. L Carlson, J. R Galloway, et al.
Plasma antioxidant status after high-dose chemotherapy: a randomized trial of parenteral nutrition in bone marrow transplantation patients
Am. J. Clinical Nutrition, July 1, 2000; 72(1): 181 - 189.
[Abstract] [Full Text] [PDF]




HOME HELP FEEDBACK SUBSCRIPTIONS ARCHIVE SEARCH TABLE OF CONTENTS
Copyright © 1981 by the American Association for Clinical Chemistry.