Clinical Chemistry Link to Randox Laboratories Web Site
HOME HELP FEEDBACK SUBSCRIPTIONS ARCHIVE SEARCH TABLE OF CONTENTS
 QUICK SEARCH:   [advanced]


     


Clinical Chemistry 28: 96-99, 1982;
This Article
Right arrow Full Text (PDF)
Right arrow Submit an electronic Letter to
the Editor about this paper
Right arrow Alert me when this article is cited
Right arrow Alert me when eLetters are posted
Right arrow Alert me if a correction is posted
Services
Right arrow Email this article to a friend
Right arrow Similar articles in this journal
Right arrow Similar articles in PubMed
Right arrow Alert me to new issues of the journal
Right arrow Download to citation manager
Right arrow reprints & permissions
Citing Articles
Right arrow Citing Articles via Google Scholar
Google Scholar
Right arrow Articles by Walinder, O.
Right arrow Articles by Fager, P. J.
Right arrow Search for Related Content
PubMed
Right arrow PubMed Citation
Right arrow Articles by Walinder, O.
Right arrow Articles by Fager, P. J.

Clinical Chemistry, Vol 28, 96-99, Copyright © 1982 by American Association for Clinical Chemistry

New spectrophotometric method for the determination of hemoglobin A1 compared with a microcolumn technique

O Walinder, G Ronquist and PJ Fager

We compared a spectrophotometric kit method (Glycospec) for determination of glycosylated hemoglobin (HbA1) with a microcolumn kit method (Bio-Rad). The Glycospec method is based on the change in absorbance when phytic acid binds to hemoglobin A. With glycosylated hemoglobin there is no such change because the binding is blocked by the sugar moiety. Inter-assay CVs were 2-6% for both methods. In healthy subjects the mean (+/- SD) value for HbAl was about 1% higher with the spectrophotometric than the microcolumn method. For samples from 122 diabetics the correlation between values for HbAl obtained with the two methods was acceptable (r = 0.89), although the spectrophotometric technique yielded 2-4% higher values, a difference at least partly due to the absence of 2,3-diphosphoglycerate from the spectrophotometric standards. Adding 1.8 mmol of it per liter to these standards caused displacement of the standard curve; HbAl values then agreed well with those of the microcolumn method. The spectrophotometric procedure is easily automated, and therefore is well suited for large-scale analyses if problems with standards and calibration can be solved.





HOME HELP FEEDBACK SUBSCRIPTIONS ARCHIVE SEARCH TABLE OF CONTENTS
Copyright © 1982 by the American Association for Clinical Chemistry.