Clinical Chemistry Link to Randox Laboratories Web Site
HOME HELP FEEDBACK SUBSCRIPTIONS ARCHIVE SEARCH TABLE OF CONTENTS
 QUICK SEARCH:   [advanced]


     


Clinical Chemistry 28: 2378-2382, 1982;
This Article
Right arrow Full Text (PDF)
Right arrow Submit an electronic Letter to
the Editor about this paper
Right arrow Alert me when this article is cited
Right arrow Alert me when eLetters are posted
Right arrow Alert me if a correction is posted
Services
Right arrow Email this article to a friend
Right arrow Similar articles in this journal
Right arrow Similar articles in PubMed
Right arrow Alert me to new issues of the journal
Right arrow Download to citation manager
Right arrow reprints & permissions
Citing Articles
Right arrow Citing Articles via Google Scholar
Google Scholar
Right arrow Articles by Harper, J. R.
Right arrow Articles by Orengo, A.
Right arrow Search for Related Content
PubMed
Right arrow PubMed Citation
Right arrow Articles by Harper, J. R.
Right arrow Articles by Orengo, A.

Clinical Chemistry, Vol 28, 2378-2382, Copyright © 1982 by American Association for Clinical Chemistry

Protein A-bearing Staphylococcus aureus as the solid phase in an enzyme immunoassay and its application to determination of urinary albumin

JR Harper, N Mahmoudi and A Orengo

Protein A-bearing Staphylococcus aureus was used as a solid-phase matrix in a sandwich-type enzyme immunoassay for urinary albumin. Heat- inactivated, formalin-fixed bacteria were coated with affinity-purified goat anti-human albumin, exposed to solutions containing standard or unknown concentrations of albumin, then challenged with an alkaline phosphatase/anti-human albumin conjugate obtained by periodate oxidation. Alkaline phosphatase activity bound to the bacteria was a function of albumin concentration from 25 to 1000 micrograms/L. This assay was applied to determinations of urinary albumin concentrations between 1.25 and 1000 mg/L. Between-run CV was 2.55 (63.9 mg/L concentration). Within-run CVs for albumin concentrations of 1.9, 38.1, and 638.0 mg/L were 3.7, 3.7, and 2.4%, respectively. Analytical recovery was 95 to 107% across the full working range of the assay. Bence Jones proteins and hemoglobin had no significant effect on the assay. Nonspecific binding of the enzyme-antibody conjugate was 1.3% (SD = 0.7%). Values agreed well with those by radial immunodiffusion.