Clinical Chemistry Link to Randox Laboratories Web Site
HOME HELP FEEDBACK SUBSCRIPTIONS ARCHIVE SEARCH TABLE OF CONTENTS
 QUICK SEARCH:   [advanced]


     


Clinical Chemistry 28: 2423-2426, 1982;
This Article
Right arrow Full Text (PDF)
Right arrow Submit an electronic Letter to
the Editor about this paper
Right arrow Alert me when this article is cited
Right arrow Alert me when eLetters are posted
Right arrow Alert me if a correction is posted
Services
Right arrow Email this article to a friend
Right arrow Similar articles in this journal
Right arrow Similar articles in PubMed
Right arrow Alert me to new issues of the journal
Right arrow Download to citation manager
Right arrow reprints & permissions
Citing Articles
Right arrow Citing Articles via Google Scholar
Google Scholar
Right arrow Articles by Bovaird, J. H.
Right arrow Articles by Lenhoff, H. M.
Right arrow Search for Related Content
PubMed
Right arrow PubMed Citation
Right arrow Articles by Bovaird, J. H.
Right arrow Articles by Lenhoff, H. M.

Clinical Chemistry, Vol 28, 2423-2426, Copyright © 1982 by American Association for Clinical Chemistry

Optimizing the o-phenylenediamine assay for horseradish peroxidase: effects of phosphate and pH, substrate and enzyme concentrations, and stopping reagents

JH Bovaird, TT Ngo and HM Lenhoff

Horseradish peroxidase, assayed with o-phenylenediamine, is irreversibly inactivated when incubated in phosphate buffer, 100 mmol/L, at pH 5. The inactivation depends on both duration and incubation and phosphate concentration. Phosphate was the most potent inactivator and citrate the least potent of a series of buffers tested. The inactivation is not attributable to ionic strength per se or to Na+ or K+. The observed inactivation did not occur at high concentrations (2500 nmol/L, 0.1 g/L) of enzyme; however, this "protective" effect could not be reproduced by adding bovine serum albumin or a surfactant (Tween 20) to lower concentrations of enzyme. The inactivation was independent of commercial source of the enzyme or the kind of chromogenic assay used. On the basis of this information, we optimized the assay so that it gave eightfold greater absorbance values than those reported by others. The improved assay was sensitive to as little as 0.4 pmol/L (16 ng/L) of peroxidase, and was linear over the range of 0.4 to 5 pmol/L (16-200 ng/L).