Clinical Chemistry AACC Online Job Center
HOME HELP FEEDBACK SUBSCRIPTIONS ARCHIVE SEARCH TABLE OF CONTENTS
 QUICK SEARCH:   [advanced]


     


Clinical Chemistry 28: 1352-1355, 1982;
This Article
Right arrow Full Text (PDF)
Right arrow Submit an electronic Letter to
the Editor about this paper
Right arrow Alert me when this article is cited
Right arrow Alert me when eLetters are posted
Right arrow Alert me if a correction is posted
Services
Right arrow Email this article to a friend
Right arrow Similar articles in this journal
Right arrow Similar articles in PubMed
Right arrow Alert me to new issues of the journal
Right arrow Download to citation manager
Right arrow reprints & permissions
Citing Articles
Right arrow Citing Articles via HighWire
Right arrow Citing Articles via Google Scholar
Google Scholar
Right arrow Articles by Neels, H. M.
Right arrow Articles by Van Acker, K. J.
Right arrow Search for Related Content
PubMed
Right arrow PubMed Citation
Right arrow Articles by Neels, H. M.
Right arrow Articles by Van Acker, K. J.

Clinical Chemistry, Vol 28, 1352-1355, Copyright © 1982 by American Association for Clinical Chemistry

Improved micromethod for assay of serum angiotensin converting enzyme

HM Neels, SL Scharpe, ME van Sande, RM Verkerk and KJ Van Acker

We describe conditions for determining angiotensin converting enzyme (EC 3.4.15.1) in serum, by liquid chromatography. Serum (10 microL) is assayed with the artificial substrate hippuryl-glycyl-glycine (30 mmol/L) in a 50 mmol/L "HEPES" buffer solution with a high salt content (300 mmol of NaCl and 400 mmol of Na2SO4 per liter), at pH 8.0. The resulting enzymic activity is ninefold that of the currently popular spectrophotometric assay of Cushman and Cheung as modified by Lieberman (Am. J. Med. 59: 365-372, 1975). The hippuric acid end product is separated from the substrate by reversed-phase liquid chromatography and measured spectrophotometrically at 228 nm. o-Methyl hippuric acid is used as internal standard. The mean value for 100 normal control subjects was 317 (SD 96) nmol of hippuric acid released per milliliter of serum per minute. The enzyme activity is greater in newborns (p less than 0.05) and has a tendency to decrease with age. This partly automated method, which is optimized with regard to activity and detection, can be used in clinical routine.


The following articles in journals at HighWire Press have cited this article:


Home page
BloodHome page
Z. Shariat-Madar, F. Mahdi, M. Warnock, J. W. Homeister, S. Srikanth, Y. Krijanovski, L. J. Murphey, A. A. Jaffa, and A. H. Schmaier
Bradykinin B2 receptor knockout mice are protected from thrombosis by increased nitric oxide and prostacyclin
Blood, July 1, 2006; 108(1): 192 - 199.
[Abstract] [Full Text] [PDF]


Home page
J. Clin. Endocrinol. Metab.Home page
F. Perticone, R. Ceravolo, S. Iacopino, C. Cloro, G. Ventura, R. Maio, E. Gulletta, N. Perrotti, and P. L. Mattioli
Relationship between Angiotensin-Converting Enzyme Gene Polymorphism and Insulin Resistance in Never-Treated Hypertensive Patients
J. Clin. Endocrinol. Metab., January 1, 2001; 86(1): 172 - 178.
[Abstract] [Full Text]


Home page
HypertensionHome page
S. Nakamura, A. Moriguchi, R. Morishita, K. Yamada, T. Nishii, N. Tomita, M. Ohishi, Y. Kaneda, J. Higaki, and T. Ogihara
Activation of the Brain Angiotensin System by In Vivo Human Angiotensin-Converting Enzyme Gene Transfer in Rats
Hypertension, August 1, 1999; 34(2): 302 - 308.
[Abstract] [Full Text] [PDF]


Home page
CirculationHome page
A. Gardemann, T. Weiß, O. Schwartz, A. Eberbach, N. Katz, F. W. Hehrlein, H. Tillmanns, W. Waas, and W. Haberbosch
Gene Polymorphism but not Catalytic Activity of Angiotensin I–Converting Enzyme Is Associated With Coronary Artery Disease and Myocardial Infarction in Low-Risk Patients
Circulation, November 15, 1995; 92(10): 2796 - 2799.
[Abstract] [Full Text]




HOME HELP FEEDBACK SUBSCRIPTIONS ARCHIVE SEARCH TABLE OF CONTENTS
Copyright © 1982 by the American Association for Clinical Chemistry.