Clinical Chemistry Link to Randox Laboratories Web Site
HOME HELP FEEDBACK SUBSCRIPTIONS ARCHIVE SEARCH TABLE OF CONTENTS
 QUICK SEARCH:   [advanced]


     


Clinical Chemistry 29: 1713-1716, 1983;
This Article
Right arrow Full Text (PDF)
Right arrow Submit an electronic Letter to
the Editor about this paper
Right arrow Alert me when this article is cited
Right arrow Alert me when eLetters are posted
Right arrow Alert me if a correction is posted
Right arrow Citation Map
Services
Right arrow Email this article to a friend
Right arrow Similar articles in this journal
Right arrow Similar articles in PubMed
Right arrow Alert me to new issues of the journal
Right arrow Download to citation manager
Right arrow reprints & permissions
Citing Articles
Right arrow Citing Articles via HighWire
Right arrow Citing Articles via Google Scholar
Google Scholar
Right arrow Articles by Noto, A.
Right arrow Articles by Miyake, T.
Right arrow Search for Related Content
PubMed
Right arrow PubMed Citation
Right arrow Articles by Noto, A.
Right arrow Articles by Miyake, T.

Clinical Chemistry, Vol 29, 1713-1716, Copyright © 1983 by American Association for Clinical Chemistry

Simple, rapid spectrophotometry of urinary N-acetyl-beta-D- glucosaminidase, with use of a new chromogenic substrate

A Noto, Y Ogawa, S Mori, M Yoshioka, T Kitakaze, T Hori, M Nakamura and T Miyake

We have developed a new spectrophotometric assay for urinary N-acetyl- beta-D-glucosaminidase (NAGase) with use of sodio m- cresolsulfonphthaleinyl N-acetyl-beta-D-glucosaminide (MCP-NAG). MCP- NAG was synthesized from acetochloro-glucosamine and m- cresolsulfonphthalein (MCP) in four steps. MCP-NAG reacts well with NAGase (Km = 0.41 mmol/L) and is highly water soluble. The absorption maximum and molar absorptivity of the aglycone MCP are 580 nm and 40 670, respectively. Spectral overlap of interfering substances at 580 nm is almost negligible, so that the urine blank can be omitted from the assay procedure. The high molar absorptivity of MCP gives sufficient analytical sensitivity at a reaction time of 15 min. The correlation between the MCP-NAG method (y) and the fluorimetric method (x) involving 4-methylumbelliferyl N-acetyl-beta-D-glucosaminide is represented by the equation y = 0.995x - 0.669 (r = 0.991). Thus, the present method provides practical advantages over conventional methods, for use in the routine laboratory.


The following articles in journals at HighWire Press have cited this article:


Home page
ANN OCCUP HYGHome page
A. FRANKO, M. V. BUDIHNA, and M. DODIC-FIKFAK
Long-Term Effects of Elemental Mercury on Renal Function in Miners of the Idrija Mercury Mine
Ann. Hyg., August 1, 2005; 49(6): 521 - 527.
[Abstract] [Full Text] [PDF]


Home page
Clin. Chem.Home page
P. L. Drake, E. Krieg, A. W. Teass, and V. Vallyathan
Two Assays for Urinary N-Acetyl-{beta}-D-glucosaminidase Compared
Clin. Chem., September 1, 2002; 48(9): 1604 - 1605.
[Full Text] [PDF]


Home page
Nephrol Dial TransplantHome page
R. O. von Vigier, A. C. Truttmann, K. Zindler-Schmocker, A. Bettinelli, C. C. Aebischer, B. Wermuth, and M. G. Bianchetti
Aminoglycosides and renal magnesium homeostasis in humans
Nephrol. Dial. Transplant., June 1, 2000; 15(6): 822 - 826.
[Abstract] [Full Text] [PDF]


Home page
J CARDIOVASC PHARMACOL THERHome page
Y. Uehara, N. Hirawa, A. Numabe, Y. Kawabata, H. Nagoshi, H. Negoro, S. Fujiwara, T. Gomi, T. Ikeda, A. Goto, et al.
Angiotensin-Converting Enzyme Inhibition Delays Onset of Glucosuria With Regression of Renal Injuries in Genetic Rat Model of Non-Insulin-Dependent Diabetes Mellitus
Journal of Cardiovascular Pharmacology and Therapeutics, January 1, 1998; 3(4): 327 - 335.
[Abstract] [PDF]


Home page
Clin. Chem.Home page
Y. Numata, A. Morita, Y. Kosugi, K. Shibata, N. Takeuchi, and K. Uchida
New sandwich ELISA for human urinary N-acetyl-{beta}-D-glucosaminidase isoenzyme B as a useful clinical test
Clin. Chem., April 1, 1997; 43(4): 569 - 574.
[Abstract] [Full Text] [PDF]




HOME HELP FEEDBACK SUBSCRIPTIONS ARCHIVE SEARCH TABLE OF CONTENTS
Copyright © 1983 by the American Association for Clinical Chemistry.