Clinical Chemistry AACC Online Job Center
HOME HELP FEEDBACK SUBSCRIPTIONS ARCHIVE SEARCH TABLE OF CONTENTS
 QUICK SEARCH:   [advanced]


     


Clinical Chemistry 29: 609-613, 1983;
This Article
Right arrow Full Text (PDF)
Right arrow Submit an electronic Letter to
the Editor about this paper
Right arrow Alert me when this article is cited
Right arrow Alert me when eLetters are posted
Right arrow Alert me if a correction is posted
Services
Right arrow Email this article to a friend
Right arrow Similar articles in this journal
Right arrow Similar articles in PubMed
Right arrow Alert me to new issues of the journal
Right arrow Download to citation manager
Right arrow reprints & permissions
Citing Articles
Right arrow Citing Articles via Google Scholar
Google Scholar
Right arrow Articles by Perry, J. F.
Right arrow Articles by Wehrly, J. A.
Right arrow Search for Related Content
PubMed
Right arrow PubMed Citation
Right arrow Articles by Perry, J. F.
Right arrow Articles by Wehrly, J. A.

Clinical Chemistry, Vol 29, 609-613, Copyright © 1983 by American Association for Clinical Chemistry

Development and analytical performance of automated tests for antithrombin III and plasminogen on the Du Pont aca analyzer

JF Perry, GE Siefring Jr, MC Reider, PL Coleman and JA Wehrly

We describe assays for functional antithrombin III (AT III) and plasminogen in plasma with the Du Pont aca discrete clinical analyzer. Both are two-stage kinetic assays, based on synthetic substrate methodologies, and require 20-microL sample volumes. In the AT III assay the sample is incubated with excess thrombin and heparin to form the functionally inactive AT III-thrombin complex. Residual thrombin is measured through its rate of hydrolysis of a lysine thioester and is inversely related to analyte concentration. In the plasminogen assay excess streptokinase is reacted with the sample to form an enzymatically active complex. The substrate hydrolysis rate of this complex is measured, which is linearly related to the concentration of plasminogen in the sample. Reaction conditions for both assays were optimized by univariate and response surface techniques. The assay for AT III has a range of 0 to 150% of the value for normal human plasma (% NHP) with a CV of 3% at 80% NHP. The plasminogen assay is linear from 25 to 200% NHP with a CV of less than 2% at 80% NHP. No significant interferences with either method by common blood components or drugs were found.