Clinical Chemistry Link to Randox Laboratories Web Site
HOME HELP FEEDBACK SUBSCRIPTIONS ARCHIVE SEARCH TABLE OF CONTENTS
 QUICK SEARCH:   [advanced]


     


Clinical Chemistry 29: 645-649, 1983;
This Article
Right arrow Full Text (PDF)
Right arrow Submit an electronic Letter to
the Editor about this paper
Right arrow Alert me when this article is cited
Right arrow Alert me when eLetters are posted
Right arrow Alert me if a correction is posted
Services
Right arrow Email this article to a friend
Right arrow Similar articles in this journal
Right arrow Similar articles in PubMed
Right arrow Alert me to new issues of the journal
Right arrow Download to citation manager
Right arrow reprints & permissions
Citing Articles
Right arrow Citing Articles via HighWire
Right arrow Citing Articles via Google Scholar
Google Scholar
Right arrow Articles by Sundberg, M. W.
Right arrow Articles by Goodhue, C. T.
Right arrow Search for Related Content
PubMed
Right arrow PubMed Citation
Right arrow Articles by Sundberg, M. W.
Right arrow Articles by Goodhue, C. T.

Clinical Chemistry, Vol 29, 645-649, Copyright © 1983 by American Association for Clinical Chemistry

An enzymic creatinine assay and a direct ammonia assay in coated thin films

MW Sundberg, RW Becker, TW Esders, J Figueras and CT Goodhue

We developed a thin-film enzymic assay for creatinine that makes use of creatinine iminohydrolase (EC 3.5.4.21) to convert creatinine to N- methylhydantoin and ammonia. The ammonia diffuses through a semipermeable layer and is quantitated by reaction with bromphenol blue. A paired analysis of the sample on a separate coating without the enzymic reaction measures endogenous ammonia and, for samples with normal concentrations of ammonia, allows accurate determination of serum creatinine to 150 mg/L without dilution. Results of this assay (y) compare well with those by a liquid-chromatographic comparison assay (x) by linear regression (slope = 0.935, intercept = 1.13 mg/L, r2 = 0.995). It is insensitive to many substances, such as ketones and keto acids, that interfere with conventional assays. Results of the ammonia assay (y) correlate well with those by a semi-automated enzymic assay (x) based on glutamate dehydrogenase (slope = 1.068, intercept = 17.3 mumol/L, r2 = 0.985).


The following articles in journals at HighWire Press have cited this article:


Home page
Ann Clin BiochemHome page
R. P Barbagallo, N. Boley, G. Holcombe, S. Merson, C. Mussell, C. Pritchard, P. Stokes, S. Wood, D. Ducroq, and A. Thomas
Production and certification of four frozen human serum certified reference materials containing creatinine and electrolytes
Ann Clin Biochem, March 1, 2008; 45(2): 160 - 166.
[Abstract] [Full Text] [PDF]


Home page
Clin. Chem.Home page
G. L. Myers, W. G. Miller, J. Coresh, J. Fleming, N. Greenberg, T. Greene, T. Hostetter, A. S. Levey, M. Panteghini, M. Welch, et al.
Recommendations for Improving Serum Creatinine Measurement: A Report from the Laboratory Working Group of the National Kidney Disease Education Program
Clin. Chem., January 1, 2006; 52(1): 5 - 18.
[Abstract] [Full Text] [PDF]


Home page
Arch. Dis. Child.Home page
S L Chow, V Gandhi, S Krywawych, P T Clayton, J V Leonard, and A A M Morris
The significance of a high plasma ammonia value
Arch. Dis. Child., June 1, 2004; 89(6): 585 - 586.
[Abstract] [Full Text] [PDF]




HOME HELP FEEDBACK SUBSCRIPTIONS ARCHIVE SEARCH TABLE OF CONTENTS
Copyright © 1983 by the American Association for Clinical Chemistry.