Clinical Chemistry AACC Online Job Center
HOME HELP FEEDBACK SUBSCRIPTIONS ARCHIVE SEARCH TABLE OF CONTENTS
 QUICK SEARCH:   [advanced]


     


Clinical Chemistry 32: 446-452, 1986;
This Article
Right arrow Full Text (PDF)
Right arrow Submit an electronic Letter to
the Editor about this paper
Right arrow Alert me when this article is cited
Right arrow Alert me when eLetters are posted
Right arrow Alert me if a correction is posted
Right arrow Citation Map
Services
Right arrow Email this article to a friend
Right arrow Similar articles in this journal
Right arrow Similar articles in PubMed
Right arrow Alert me to new issues of the journal
Right arrow Download to citation manager
Right arrow reprints & permissions
Citing Articles
Right arrow Citing Articles via HighWire
Right arrow Citing Articles via Google Scholar
Google Scholar
Right arrow Articles by Kroll, M. H.
Right arrow Articles by Rawe, M.
Right arrow Search for Related Content
PubMed
Right arrow PubMed Citation
Right arrow Articles by Kroll, M. H.
Right arrow Articles by Rawe, M.

Clinical Chemistry, Vol 32, 446-452, Copyright © 1986 by American Association for Clinical Chemistry

Automated determination of urinary creatinine without sample dilution: theory and practice

MH Kroll, R Chesler, C Hagengruber, DW Blank, J Kestner and M Rawe

The rate of the Jaffe reaction depends on the concentration of sodium hydroxide; the pseudo-first-order rate constant of the reaction, at 37 degrees C in 10 mmol/L picrate solution, is 0.004 mmol/L. We formulated an automated method to determine urinary creatinine directly without manual sample dilution. The conditions are as follows: 10 mmol/L picrate and 60 mmol/L sodium hydroxide (final concentrations); ratio of sample to final volume, 1:41; temperature, 37 degrees C; wavelengths of measurement, 500 or 510 nm; interval of measurement, 30 to 90 s; and mode of measurement, kinetic. Determinations of creatinine in patients' samples by the new method compared favorably with those obtained with the AutoAnalyzer and aca. The run-to-run CVs were 3.6% or less, and the method was accurate for concentrations of creatinine up to 3000 mg/L. We recommend this method as a good replacement for the AutoAnalyzer or aca methods.


The following articles in journals at HighWire Press have cited this article:


Home page
CJASNHome page
C. Lorenzo, S. D. Nath, A. J.G. Hanley, H. E. Abboud, and S. M. Haffner
Relation of Low Glomerular Filtration Rate to Metabolic Disorders in Individuals without Diabetes and with Normoalbuminuria
Clin. J. Am. Soc. Nephrol., May 1, 2008; 3(3): 783 - 789.
[Abstract] [Full Text] [PDF]


Home page
J. Nutr.Home page
R. A. Jacob, G. M. Aiello, C. B. Stephensen, J. B. Blumberg, P. E. Milbury, L. M. Wallock, and B. N. Ames
Moderate Antioxidant Supplementation Has No Effect on Biomarkers of Oxidant Damage in Healthy Men with Low Fruit and Vegetable Intakes
J. Nutr., March 1, 2003; 133(3): 740 - 743.
[Abstract] [Full Text] [PDF]


Home page
J. Nutr.Home page
R. A. Jacob, D. M. Gretz, P. C. Taylor, S. J. James, I. P. Pogribny, B. J. Miller, S. M. Henning, and M. E. Swendseid
Moderate Folate Depletion Increases Plasma Homocysteine and Decreases Lymphocyte DNA Methylation in Postmenopausal Women
J. Nutr., July 1, 1998; 128(7): 1204 - 1212.
[Abstract] [Full Text] [PDF]


Home page
StrokeHome page
L. Mykkanen, D. J. Zaccaro, D. H. O'Leary, G. Howard, D. C. Robbins, and S. M. Haffner
Microalbuminuria and Carotid Artery Intima-Media Thickness in Nondiabetic and NIDDM Subjects : The Insulin Resistance Atherosclerosis Study (IRAS)
Stroke, September 1, 1997; 28(9): 1710 - 1716.
[Abstract] [Full Text]


Home page
CirculationHome page
J. Kuusisto, L. Mykkanen, K. Pyorala, and M. Laakso
Hyperinsulinemic Microalbuminuria : A New Risk Indicator for Coronary Heart Disease
Circulation, February 1, 1995; 91(3): 831 - 837.
[Abstract] [Full Text]




HOME HELP FEEDBACK SUBSCRIPTIONS ARCHIVE SEARCH TABLE OF CONTENTS
Copyright © 1986 by the American Association for Clinical Chemistry.