Clinical Chemistry AACC Online Job Center
HOME HELP FEEDBACK SUBSCRIPTIONS ARCHIVE SEARCH TABLE OF CONTENTS
 QUICK SEARCH:   [advanced]


     


Clinical Chemistry 32: 752-757, 1986;
This Article
Right arrow Full Text (PDF)
Right arrow Submit an electronic Letter to
the Editor about this paper
Right arrow Alert me when this article is cited
Right arrow Alert me when eLetters are posted
Right arrow Alert me if a correction is posted
Services
Right arrow Email this article to a friend
Right arrow Similar articles in this journal
Right arrow Similar articles in PubMed
Right arrow Alert me to new issues of the journal
Right arrow Download to citation manager
Right arrow reprints & permissions
Citing Articles
Right arrow Citing Articles via Google Scholar
Google Scholar
Right arrow Articles by Maynard, Y.
Right arrow Articles by Ladenson, J. H.
Right arrow Search for Related Content
PubMed
Right arrow PubMed Citation
Right arrow Articles by Maynard, Y.
Right arrow Articles by Ladenson, J. H.

Clinical Chemistry, Vol 32, 752-757, Copyright © 1986 by American Association for Clinical Chemistry

Turbidimetric assay of IgG with use of single monoclonal antibodies

Y Maynard, MG Scott, MH Nahm and JH Ladenson

We describe a turbidimetric assay for quantifying total immunoglobulin G (IgG) in serum with use of a single monoclonal antibody. The reaction, monitored by a centrifugal analyzer, is technically simple, rapid, and precise. Buffer of low ionic strength and polyethylene glycol are required for formation of detectable antibody-antigen complexes. We measured IgG concentrations in 49 polyclonal sera (Group 1) and 84 sera containing monoclonal IgG (Group 2) in assays in which we used either of two anti-IgG monoclonal antibodies (HG6 or HG8). Results compared well with those obtained with a nephelometric assay involving polyclonal antiserum, except for sera from four persons of Group 2 whose immunoglobulins were not detected by antibody HG6. HG6 bound IgG from these four sera in a solid-phase binding assay. HG6 and HG8 recognize epitopes on the Fab and Fc regions of IgG, respectively, and they do not compete for binding to the whole molecule. However, use of the two monoclonal antibodies combined failed to improve the sensitivity or range of the assay. We conclude that light-scattering assays of IgG can be validly performed with a single monoclonal antibody.





HOME HELP FEEDBACK SUBSCRIPTIONS ARCHIVE SEARCH TABLE OF CONTENTS