Clinical Chemistry AACC Online Job Center
HOME HELP FEEDBACK SUBSCRIPTIONS ARCHIVE SEARCH TABLE OF CONTENTS
 QUICK SEARCH:   [advanced]


     


Clinical Chemistry 32: 1692-1695, 1986;
This Article
Right arrow Full Text (PDF)
Right arrow Submit an electronic Letter to
the Editor about this paper
Right arrow Alert me when this article is cited
Right arrow Alert me when eLetters are posted
Right arrow Alert me if a correction is posted
Services
Right arrow Email this article to a friend
Right arrow Similar articles in this journal
Right arrow Similar articles in PubMed
Right arrow Alert me to new issues of the journal
Right arrow Download to citation manager
Right arrow reprints & permissions
Citing Articles
Right arrow Citing Articles via HighWire
Right arrow Citing Articles via Google Scholar
Google Scholar
Right arrow Articles by Anderson, R. R.
Right arrow Articles by Valkirs, G. E.
Right arrow Search for Related Content
PubMed
Right arrow PubMed Citation
Right arrow Articles by Anderson, R. R.
Right arrow Articles by Valkirs, G. E.

Clinical Chemistry, Vol 32, 1692-1695, Copyright © 1986 by American Association for Clinical Chemistry

Internally referenced ImmunoConcentration assays

RR Anderson, TT Lee, DC Saewert, KM Sowden and GE Valkirs

We have developed a method for incorporating an internal reference zone in addition to the test zone in a single immunoConcentration device. We have illustrated the method by constructing an internally referenced assay for human choriogonadotropin (HCG) in serum. The internally referenced assay, which can be performed in about 5 min, provides a measured overall precision (CV) of approximately 15% at a concentration, in serum, of approximately 50 int. units/L. The test zone consists of an anti-HCG antibody adsorbed onto latex microspheres and entrapped within a porous support. The reference zone contains antibody against alkaline phosphatase (EC 3.1.3.1), which has also been adsorbed onto latex microspheres and trapped within the support. The use of an internal reference moderates the effects of variations in assay conditions on the interpretation of assay results.


The following articles in journals at HighWire Press have cited this article:


Home page
Clin. Chem.Home page
A. B. Blase
How many mistakes, how to find them
Clin. Chem., May 1, 1997; 43(5): 897 - 902.
[Abstract] [Full Text] [PDF]




HOME HELP FEEDBACK SUBSCRIPTIONS ARCHIVE SEARCH TABLE OF CONTENTS
Copyright © 1986 by the American Association for Clinical Chemistry.