Clinical Chemistry AACC Online Job Center
HOME HELP FEEDBACK SUBSCRIPTIONS ARCHIVE SEARCH TABLE OF CONTENTS
 QUICK SEARCH:   [advanced]


     


Clinical Chemistry 34: 2016-2018, 1988;
This Article
Right arrow Full Text (PDF)
Right arrow Submit an electronic Letter to
the Editor about this paper
Right arrow Alert me when this article is cited
Right arrow Alert me when eLetters are posted
Right arrow Alert me if a correction is posted
Services
Right arrow Email this article to a friend
Right arrow Similar articles in this journal
Right arrow Similar articles in PubMed
Right arrow Alert me to new issues of the journal
Right arrow Download to citation manager
Right arrow reprints & permissions
Citing Articles
Right arrow Citing Articles via Google Scholar
Google Scholar
Right arrow Articles by Hafkenscheid, J. C.
Right arrow Articles by Hessels, M.
Right arrow Search for Related Content
PubMed
Right arrow PubMed Citation
Right arrow Articles by Hafkenscheid, J. C.
Right arrow Articles by Hessels, M.

Clinical Chemistry, Vol 34, 2016-2018, Copyright © 1988 by American Association for Clinical Chemistry

Some thermodynamic parameters and temperature-conversion factors for determining alpha-amylase concentration in serum [published erratum appears in Clin Chem 1989 Apr;35(4):670]

JC Hafkenscheid and M Hessels
Clinical Chemical Laboratory, St. Radboud Hospital, University of Nijmegen, The Netherlands.

We measured the relationship between measured activity concentration and temperature for alpha-amylase (EC 3.2.1.1), using 10 different substrates. At 25-37 degrees C the Arrhenius plot was linear. The activation energy ranged from 33.3 kJ.mol-1 with maltoheptaose as substrate to 54.4 kJ.mol-1 with the Blue-Starch method. Activation energy was lowest for substrates having seven glucose moieties, the ones most suitable for determining alpha-amylase--i.e., the presence of more or fewer glycosyl units increased the activation energy. Substrates with blocked groups at the nonreducing end of the oligosaccharide chain were not considered here, because the relative reaction rates obtained with these substrates were less than those obtained with nonblocked substrates. We also determined temperature- conversion factors for alpha-amylase reaction with the various substrates. The results are discussed in relation to thermodynamic parameters of some other enzymes, e.g., creatine kinase and alkaline phosphatase.





HOME HELP FEEDBACK SUBSCRIPTIONS ARCHIVE SEARCH TABLE OF CONTENTS
Copyright © 1988 by the American Association for Clinical Chemistry.