Clinical Chemistry AACC Online Job Center
HOME HELP FEEDBACK SUBSCRIPTIONS ARCHIVE SEARCH TABLE OF CONTENTS
 QUICK SEARCH:   [advanced]


     


Clinical Chemistry 34: 2283-2290, 1988;
This Article
Right arrow Full Text (PDF)
Right arrow Submit an electronic Letter to
the Editor about this paper
Right arrow Alert me when this article is cited
Right arrow Alert me when eLetters are posted
Right arrow Alert me if a correction is posted
Services
Right arrow Email this article to a friend
Right arrow Similar articles in this journal
Right arrow Similar articles in PubMed
Right arrow Alert me to new issues of the journal
Right arrow Download to citation manager
Right arrow reprints & permissions
Citing Articles
Right arrow Citing Articles via Google Scholar
Google Scholar
Right arrow Articles by Mocarelli, P.
Right arrow Articles by Mondonico, A.
Right arrow Search for Related Content
PubMed
Right arrow PubMed Citation
Right arrow Articles by Mocarelli, P.
Right arrow Articles by Mondonico, A.

Clinical Chemistry, Vol 34, 2283-2290, Copyright © 1988 by American Association for Clinical Chemistry

A new method for D-glucaric acid excretion measurement that is suitable for automated instruments

P Mocarelli, P Brambilla, L Colombo, A Marocchi, C Crespi, P Tramacere and A Mondonico
Institute of General Pathology, Faculty of Medicine, University of Milan, Italy.

Urinary excretion of D-glucaric acid (uGA) is an index of type II hepatic microsomal enzyme induction, indirectly revealing possible organic effects of some drugs and environmental pollutants. However, its determination is often cumbersome. We suggest a new, fast microanalytical method for uGA determination in which beta- glucuronidase (BG; EC 3.2.1.31) activity inhibition produced by uGA- derived 1,4-D-glucarolactone is measured. With use of purified BG, the method is suitable for centrifugal analyzers, allowing assay of greater than 100 samples per day. Moreover, the method measures uGA more accurately than other enzymatic methods based on BG inhibition. The within-day CV ranges from 7.9% to 4.6% (uGA 31.55-121.31 mumol/L); the between-day CV ranges from 11.5% to 5.0% (uGA 26.09-124.10 mumol/L). The detection limit is 6.0 mumol/L. The standard curve is linear from 10 to 200 mumol/L. Mean analytical recovery is 100%. Comparison with the method of Simmons et al. (Clin Chim Acta 1974;51:47-51) gave a correlation of r = 0.978, y = 1.40x-2.81. Reference intervals were established in a healthy population sample of 369 people (165 under 14 y), and uGA, expressed in micromoles per gram of creatinine, was higher in women than in girls or in males.