Clinical Chemistry AACC Online Job Center
HOME HELP FEEDBACK SUBSCRIPTIONS ARCHIVE SEARCH TABLE OF CONTENTS
 QUICK SEARCH:   [advanced]


     


Clinical Chemistry 34: 2337-2340, 1988;
This Article
Right arrow Full Text (PDF)
Right arrow Submit an electronic Letter to
the Editor about this paper
Right arrow Alert me when this article is cited
Right arrow Alert me when eLetters are posted
Right arrow Alert me if a correction is posted
Services
Right arrow Email this article to a friend
Right arrow Similar articles in this journal
Right arrow Similar articles in PubMed
Right arrow Alert me to new issues of the journal
Right arrow Download to citation manager
Right arrow reprints & permissions
Citing Articles
Right arrow Citing Articles via HighWire
Right arrow Citing Articles via Google Scholar
Google Scholar
Right arrow Articles by Dakubu, S.
Right arrow Articles by Weinberg, J.
Right arrow Search for Related Content
PubMed
Right arrow PubMed Citation
Right arrow Articles by Dakubu, S.
Right arrow Articles by Weinberg, J.

Clinical Chemistry, Vol 34, 2337-2340, Copyright © 1988 by American Association for Clinical Chemistry

Time-resolved pulsed fluorescence immunometric assays of carcinoembryonic antigen

S Dakubu, R Hale, A Lu, J Quick, D Solas and J Weinberg
Baxter Healthcare Corp., Cambridge, MA 02139.

A time-resolved pulsed fluorescence immunometric assay (TR-PFIA) for carcinoembryonic antigen is described in which either Eu(III) or Tb(III) chelate is used as label. Described in detail is the assay involving the well-documented format of microtiter matrix and Eu(III) fluorescence enhanced with a beta-diketone and quantified in a commercial time-resolving fluorometer. We have also used the same basic assay, but one with a Tb(III) chelate as label, and we read the fluorescence signal directly off a surface without the application of enhancement solution. The Tb(III) fluorescence is then brought into solution by using an analog of dipicolinic acid in an enhancement solution. The latter approach demonstrates the scope of the methodology, which invokes the extra complexity of enhancement only when increased sensitivity might be required. The power and versatility of the enhancement methodology are demonstrated.


The following articles in journals at HighWire Press have cited this article:


Home page
Clin. Chem.Home page
T. Soukka, J. Paukkunen, H. Harma, S. Lonnberg, H. Lindroos, and T. Lovgren
Supersensitive Time-resolved Immunofluorometric Assay of Free Prostate-specific Antigen with Nanoparticle Label Technology
Clin. Chem., July 1, 2001; 47(7): 1269 - 1278.
[Abstract] [Full Text] [PDF]




HOME HELP FEEDBACK SUBSCRIPTIONS ARCHIVE SEARCH TABLE OF CONTENTS
Copyright © 1988 by the American Association for Clinical Chemistry.