Clinical Chemistry Link to Randox Laboratories Web Site
HOME HELP FEEDBACK SUBSCRIPTIONS ARCHIVE SEARCH TABLE OF CONTENTS
 QUICK SEARCH:   [advanced]


     


Clinical Chemistry 34: 2513-2516, 1988;
This Article
Right arrow Full Text (PDF)
Right arrow Submit an electronic Letter to
the Editor about this paper
Right arrow Alert me when this article is cited
Right arrow Alert me when eLetters are posted
Right arrow Alert me if a correction is posted
Services
Right arrow Email this article to a friend
Right arrow Similar articles in this journal
Right arrow Similar articles in PubMed
Right arrow Alert me to new issues of the journal
Right arrow Download to citation manager
Right arrow reprints & permissions
Citing Articles
Right arrow Citing Articles via HighWire
Right arrow Citing Articles via Google Scholar
Google Scholar
Right arrow Articles by Ryder, K. W.
Right arrow Articles by Sample, M. M.
Right arrow Search for Related Content
PubMed
Right arrow PubMed Citation
Right arrow Articles by Ryder, K. W.
Right arrow Articles by Sample, M. M.

Clinical Chemistry, Vol 34, 2513-2516, Copyright © 1988 by American Association for Clinical Chemistry

An enzyme immunoassay procedure for cancer antigen 125 evaluated

KW Ryder, TO Oei, MT Hull and MM Sample
Department of Pathology, Indiana University School of Medicine, Wishard Memorial Hospital, Indianapolis 46202.

The performance of a new enzyme immunoassay (EIA) procedure (Abbott Labs.) for cancer antigen 125 (CA 125) met or exceeded the manufacturer's claims for all analytical variables examined. Overall correlation with results obtained with a radioimmunoassay (RIA) were good. However, near the decision thresholds typically chosen to define a positive result for ovarian carcinoma, EIA results were 10 to 20 arbitrary units/mL less than the RIA results. At specific decision thresholds, therefore, the sensitivities and specificities of the EIA and RIA procedure differed. Adjusting the decision thresholds gave a similar optimum efficiency for each procedure: EIA, 82.9% (decision threshold, 35 units/mL); RIA, 83.4% (decision threshold, 54 units/mL). Receiver-operating characteristic curves showed that the two procedures' ability to distinguish patients with active ovarian carcinoma from those with disease in remission was the same.


The following articles in journals at HighWire Press have cited this article:


Home page
Ann Rheum DisHome page
N. Tsavaris, C. P Mavragani, and P. Dimitrios
Rheumatoid arthritis: correlation between rheumatoid factor levels and CA-125 tumour marker elevation
Ann Rheum Dis, July 1, 2007; 66(7): 980 - 980.