Clinical Chemistry Link to Randox Laboratories Web Site
HOME HELP FEEDBACK SUBSCRIPTIONS ARCHIVE SEARCH TABLE OF CONTENTS
 QUICK SEARCH:   [advanced]


     


Clinical Chemistry 34: 250-256, 1988;
This Article
Right arrow Full Text (PDF)
Right arrow Submit an electronic Letter to
the Editor about this paper
Right arrow Alert me when this article is cited
Right arrow Alert me when eLetters are posted
Right arrow Alert me if a correction is posted
Services
Right arrow Email this article to a friend
Right arrow Similar articles in this journal
Right arrow Similar articles in PubMed
Right arrow Alert me to new issues of the journal
Right arrow Download to citation manager
Right arrow reprints & permissions
Citing Articles
Right arrow Citing Articles via Google Scholar
Google Scholar
Right arrow Articles by Ehrmeyer, S. S.
Right arrow Articles by Schell, K.
Right arrow Search for Related Content
PubMed
Right arrow PubMed Citation
Right arrow Articles by Ehrmeyer, S. S.
Right arrow Articles by Schell, K.

Clinical Chemistry, Vol 34, 250-256, Copyright © 1988 by American Association for Clinical Chemistry

Use of alternative rules (other than the 1(2)s) for evaluating interlaboratory performance data

SS Ehrmeyer, RH Laessig and K Schell
School of Allied Health Professions, Medical Technology Program, University of Wisconsin-Madison 53706.

Previous studies have documented the ineffectiveness of using either the group mean +/- 2 group standard deviations (SD) or the 1(2)s rule as the standard of acceptable performance in evaluating interlaboratory proficiency testing (PT) data. Using computer simulation of PT data, we evaluated the efficiency of 244 alternatives to the 1(2)s rule, all based on the PT population's mean and SD. Using the traditional interlaboratory PT format, we determined the ability of each rule to correctly identify both good and deficient intralaboratory performance. The rules are based on results from one to five PT samples "analyzed" at the same time. Because the effectiveness of the criteria set for acceptable performance in a PT program is influenced by the population SD, each rule's capabilities were examined for PT populations with interlaboratory SDs ranging from 1% through 10% of the population mean value. All rules achieve their maximum efficiency over a narrow range of interlaboratory SDs. For PT evaluations of intralaboratory performance to be optimally effective, selection of the rule must be based on the SD of the PT population.