Clinical Chemistry Link to Randox Laboratories Web Site
HOME HELP FEEDBACK SUBSCRIPTIONS ARCHIVE SEARCH TABLE OF CONTENTS
 QUICK SEARCH:   [advanced]


     


Clinical Chemistry 34: 568-575, 1988;
This Article
Right arrow Full Text (PDF)
Right arrow Submit an electronic Letter to
the Editor about this paper
Right arrow Alert me when this article is cited
Right arrow Alert me when eLetters are posted
Right arrow Alert me if a correction is posted
Services
Right arrow Email this article to a friend
Right arrow Similar articles in this journal
Right arrow Similar articles in PubMed
Right arrow Alert me to new issues of the journal
Right arrow Download to citation manager
Right arrow reprints & permissions
Citing Articles
Right arrow Citing Articles via HighWire
Right arrow Citing Articles via Google Scholar
Google Scholar
Right arrow Articles by Wians, F. H.
Right arrow Articles by Ortiz, G.
Right arrow Search for Related Content
PubMed
Right arrow PubMed Citation
Right arrow Articles by Wians, F. H., Jr
Right arrow Articles by Ortiz, G.

Clinical Chemistry, Vol 34, 568-575, Copyright © 1988 by American Association for Clinical Chemistry

Thyrotroph function assessed by sensitive measurement of thyrotropin with three immunoradiometric assay kits: analytical evaluation and comparison with the thyroliberin stimulation test

FH Wians Jr, JM Jacobson, J Dev, JI Heald and G Ortiz
Department of Pathology/SGHQLCC, Wilford Hall USAF Medical Center, Lackland AFB, San Antonio, TX 78236-5300.

We evaluated the analytical and clinical performance of three "sensitive" immunoradiometric assay (IRMA) kits (Tandem-R TSH HS, Hybritech, Inc.; EchoClonal TSH, Bio-Rad; Coat-A-Count TSH IRMA, Diagnostic Products Corp.) for measurement of thyrotropin (TSH) and compared their performance against a "regular" IRMA (ARIA-HT, Becton- Dickinson) to determine whether these assays might eliminate the need to perform the thyroliberin (TRF) stimulation test. We concluded that the Tandem and EchoClonal kits may obviate the need to perform TRF stimulation tests in some patients. Using only the basal TSH concentration to predict the TSH response to TRF, we found all three sensitive TSH assays to be useful for detecting abnormal thyrotroph function. Dose-response, linearity, analytical recovery, and specificity were acceptable for all kits, but intra-assay precision at very low TSH concentrations and analytical sensitivity differed considerably among the kits. Using the EchoClonal assay, we established a normal reference interval for TSH of 0.4-4.6 milli-int. units/L.


The following articles in journals at HighWire Press have cited this article:


Home page
EndocrinologyHome page
P.-J. Tai, Y.-H. Huang, C.-H. Shih, R.-N. Chen, C.-D. Chen, W.-J. Chen, C.-S. Wang, and K.-H. Lin
Direct Regulation of Androgen Receptor-Associated Protein 70 by Thyroid Hormone and Its Receptors
Endocrinology, July 1, 2007; 148(7): 3485 - 3495.
[Abstract] [Full Text] [PDF]




HOME HELP FEEDBACK SUBSCRIPTIONS ARCHIVE SEARCH TABLE OF CONTENTS
Copyright © 1988 by the American Association for Clinical Chemistry.