Clinical Chemistry Link to Randox Laboratories Web Site
HOME HELP FEEDBACK SUBSCRIPTIONS ARCHIVE SEARCH TABLE OF CONTENTS
 QUICK SEARCH:   [advanced]


     


Clinical Chemistry 38: 1954-1958, 1992;
This Article
Right arrow Full Text (PDF)
Right arrow Submit an electronic Letter to
the Editor about this paper
Right arrow Alert me when this article is cited
Right arrow Alert me when eLetters are posted
Right arrow Alert me if a correction is posted
Services
Right arrow Email this article to a friend
Right arrow Similar articles in this journal
Right arrow Similar articles in PubMed
Right arrow Alert me to new issues of the journal
Right arrow Download to citation manager
Right arrow reprints & permissions
Citing Articles
Right arrow Citing Articles via Google Scholar
Google Scholar
Right arrow Articles by Ogiwara, S.
Right arrow Articles by Sugimoto, T.
Right arrow Search for Related Content
PubMed
Right arrow PubMed Citation
Right arrow Articles by Ogiwara, S.
Right arrow Articles by Sugimoto, T.

Clinical Chemistry, Vol 38, 1954-1958, Copyright © 1992 by American Association for Clinical Chemistry

Highly sensitive, specific enzyme-linked immunosorbent assay of neopterin and biopterin in biological samples

S Ogiwara, K Kiuchi, T Nagatsu, R Teradaira, I Nagatsu, K Fujita and T Sugimoto
Department of Pharmacology, Nagoya University School of Medicine, Japan.

An enzyme immunosorbent assay of neopterin and biopterin on a polystyrene microtiter plate has been developed. A conjugate of neopterin or biopterin to bovine serum albumin was used to raise a specific antiserum against neopterin or biopterin in rabbits. An incubation mixture of the antiserum and samples prepared from human serum underwent another antigen-antibody reaction with the hapten fixed on the microtiter plate. The amount of antibody bound to the fixed hapten, which is inverse to the amount of hapten in the sample, was determined by using anti-rabbit IgG-horseradish peroxidase conjugate in a usual manner by measuring absorbance at 490 nm after reaction with o- phenylenediamine and hydrogen peroxide. The minimal detectable amounts of neopterin and biopterin were approximately 0.1 pmol. The specificity of the assay was so high that the assay system for neopterin completely distinguished it from biopterin, as judged from the cross-reaction of 0.002%, and vice versa. The amounts of neopterin and biopterin in human serum determined by the present method agreed well with those determined by high-performance liquid chromatography. We used the present method to determine the concentrations of neopterin in serum from healthy control subjects and patients with cancers and systemic lupus erythematosus; the results were consistent with literature data.