Clinical Chemistry Link to Randox Laboratories Web Site
HOME HELP FEEDBACK SUBSCRIPTIONS ARCHIVE SEARCH TABLE OF CONTENTS
 QUICK SEARCH:   [advanced]


     


Clinical Chemistry 38: 407-411, 1992;
This Article
Right arrow Full Text (PDF)
Right arrow Submit an electronic Letter to
the Editor about this paper
Right arrow Alert me when this article is cited
Right arrow Alert me when eLetters are posted
Right arrow Alert me if a correction is posted
Services
Right arrow Email this article to a friend
Right arrow Similar articles in this journal
Right arrow Similar articles in PubMed
Right arrow Alert me to new issues of the journal
Right arrow Download to citation manager
Right arrow reprints & permissions
Citing Articles
Right arrow Citing Articles via Google Scholar
Google Scholar
Right arrow Articles by Paroni, R.
Right arrow Articles by Bonini, P. A.
Right arrow Search for Related Content
PubMed
Right arrow PubMed Citation
Right arrow Articles by Paroni, R.
Right arrow Articles by Bonini, P. A.

Clinical Chemistry, Vol 38, 407-411, Copyright © 1992 by American Association for Clinical Chemistry

Total urinary hydroxyproline determined with rapid and simple high- performance liquid chromatography

R Paroni, E De Vecchi, I Fermo, C Arcelloni, L Diomede, F Magni and PA Bonini
Istituto Scientifico H. San Raffaele, Milano, Italy.

A precolumn derivatization method was optimized for rapid and specific analysis of total urinary hydroxyproline by HPLC. After an overnight hydrolysis, urine samples dried and reconstituted with the internal standard cysteic acid (in sodium hydrogen carbonate, pH 9.3) were derivatized with N,N-diethyl-2,4-dinitro-5-fluoroaniline (FDNDEA) at 100 degrees C for 20 min. The DNDEA-hydroxyproline adduct was separated on an Ultrasphere ODS column with a mobile phase of acetate buffer (containing triethylamine, 6 mL/L, pH 4.3) and acetonitrile (80/20, by vol), and was detected at 360 nm. A single run took 18 min with a hydroxyproline retention time of 7.3 min. The assay showed a linear response to hydroxyproline concentrations from 5 to 100 mg/L with a detection limit of 0.8 ng injected, corresponding to 2 mg/L in urine. Mean (SD) analytical recovery was 94.2 (13)% and 104 (9)% at 10 and 50 mg/L, respectively. Within-run and between-run CVs (n = 10) were 3.74% and 4.33%, respectively, for 25 mg/L. Results for samples (n = 50) analyzed by HPLC (y) vs ion-exchange chromatography with postcolumn ninhydrin reaction (x) correlated well: y = 0.98x + 1.02 (r = 0.985, Sxy = 3.13). In another comparison, involving 173 samples, a colorimetric procedure (Hypronosticon, x) gave slightly higher values than the HPLC method (y): y = 0.83x + 2.21 (r = 0.937, Sxy = 4.6).





HOME HELP FEEDBACK SUBSCRIPTIONS ARCHIVE SEARCH TABLE OF CONTENTS
Copyright © 1992 by the American Association for Clinical Chemistry.