|
|
||||||||
Clinical Chemistry, Vol 38, 651-657, Copyright © 1992 by American Association for Clinical Chemistry
ST Bennett, JH Eckfeldt, JD Belcher and DP Connelly
Department of Laboratory Medicine and Pathology, UMHC, Minneapolis.
The National Reference Method Laboratory Network has initiated a program to certify clinical laboratory cholesterol measurement performance by using routine clinical specimens. Clinical laboratory and reference laboratory measurements of split samples are used to assess whether the clinical laboratory is meeting the Laboratory Standardization Panel's goals for accuracy and precision. We used a computer-based Monte Carlo simulation model of split-sample proficiency testing to evaluate the certification program and, in particular, to analyze the effects of reference laboratory bias and imprecision. Results of our simulations indicate that the accuracy of the certification program is strongly influenced by reference laboratory bias and less influenced by reference laboratory imprecision. The certification program is potentially highly accurate, but unless reference laboratory bias is tightly controlled, the number of classification errors may limit its utility. Moreover, the decision limit of the certification program needs to be higher than the Laboratory Standardization Panel's goal (3.5% instead of 3.0%) to ensure that an acceptably high proportion of well-performing clinical laboratories can become certified.
The following articles in journals at HighWire Press have cited this article:
![]() |
S. Branford, L. Fletcher, N. C. P. Cross, M. C. Muller, A. Hochhaus, D.-W. Kim, J. P. Radich, G. Saglio, F. Pane, S. Kamel-Reid, et al. Desirable performance characteristics for BCR-ABL measurement on an international reporting scale to allow consistent interpretation of individual patient response and comparison of response rates between clinical trials Blood, October 15, 2008; 112(8): 3330 - 3338. [Abstract] [Full Text] [PDF] |
||||
![]() |
J. Middleton Effect of Analytical Error on the Assessment of Cardiac Risk by the High-Sensitivity C-Reactive Protein and Lipid Screening Model Clin. Chem., November 1, 2002; 48(11): 1955 - 1962. [Abstract] [Full Text] [PDF] |
||||
![]() |
G. L. Myers, M. M. Kimberly, P. P. Waymack, S. J. Smith, G. R. Cooper, and E. J. Sampson A Reference Method Laboratory Network for Cholesterol: A Model for Standardization and Improvement of Clinical Laboratory Measurements Clin. Chem., November 1, 2000; 46(11): 1762 - 1772. [Abstract] [Full Text] [PDF] |
||||
![]() |
M. M. Kimberly, E. T. Leary, T. G. Cole, and P. P. Waymack Selection, Validation, Standardization, and Performance of a Designated Comparison Method for HDL-Cholesterol for Use in the Cholesterol Reference Method Laboratory Network Clin. Chem., October 1, 1999; 45(10): 1803 - 1812. [Abstract] [Full Text] [PDF] |
||||
| HOME | HELP | FEEDBACK | SUBSCRIPTIONS | ARCHIVE | SEARCH | TABLE OF CONTENTS |