Clinical Chemistry
HOME HELP FEEDBACK SUBSCRIPTIONS ARCHIVE SEARCH TABLE OF CONTENTS
 QUICK SEARCH:   [advanced]


     


Clinical Chemistry 46: 1755-1761, 2000;
This Article
Right arrow Full Text
Right arrow Full Text (PDF)
Right arrow Alert me when this article is cited
Right arrow Alert me if a correction is posted
Right arrow Citation Map
Services
Right arrow Email this article to a friend
Right arrow Similar articles in this journal
Right arrow Similar articles in Web of Science
Right arrow Similar articles in PubMed
Right arrow Alert me to new issues of the journal
Right arrow Download to citation manager
Right arrow reprints & permissions
Citing Articles
Right arrow Citing Articles via HighWire
Right arrow Citing Articles via Web of Science (12)
Right arrow Citing Articles via Google Scholar
Google Scholar
Right arrow Articles by Härmä, H.
Right arrow Articles by Lövgren, T.
Right arrow Search for Related Content
PubMed
Right arrow PubMed Citation
Right arrow Articles by Härmä, H.
Right arrow Articles by Lövgren, T.
Related Collections
Right arrow Proteomics and Protein Markers
Right arrow Automation and Analytical Techniques
(Clinical Chemistry. 2000;46:1755-1761.)
© 2000 American Association for Clinical Chemistry, Inc.


Articles

Miniature Single-Particle Immunoassay for Prostate-specific Antigen in Serum Using Recombinant Fab Fragments

Harri Härmäa,1, Piia Tarkkinen1, Tero Soukka1 and Timo Lövgren1

1 Department of Biotechnology, University of Turku, Tykistökatu 6A, FIN-20520 Turku, Finland.
a Author for correspondence. fax 358-2-3338050; e-mail harri.harma{at}utu.fi

Background: Quantitative, miniaturized nucleic acid assays and immunoassays can be developed with single microparticles, microfluorometric detection, and intrinsically fluorescent lanthanide chelates in a multiple assay format to decrease reagent consumption, cost, and assay time. We used recombinant Fab fragments to capture and detect free and total prostate-specific antigen (PSA) from serum in a submicroliter volume single-particle immunoassay.

Methods: Genetically engineered thiol-Fab or thiolated monoclonal antibodies (mAbs) were covalently attached onto uniformly sized 60-µm maleimide-activated microparticles. Free and total PSA were detected with europium- or terbium-labeled Fab fragments on a single microparticle using a microfluorometer in a time-resolved mode.

Results: The detection limit of the free- and total-PSA assays (mean + 3 SD of zero calibrator) was 0.35 µg/L, with a total volume of 330 nL per particle. An excellent correlation was found in microparticle and microtiter-well assays for 21 serum samples: slopes for free and total PSA were 1.06 ± 0.03 and 1.03 ± 0.02, respectively (Sy|x = 0.084 and 0.057 µg/L), with intercepts of 0.013 ± 0.018 and 0.013 ± 0.017 µg/L (R >0.99). Furthermore, the particle-immobilized Fab fragment had a PSA binding capacity 1.5-fold higher than the intact mAb capacity on a single microparticle. Capacity, kinetics, and sensitivity of the Fab fragment and intact mAb assays in the microparticle and microtiter well formats are discussed.

Conclusions: With site-specific (cysteine tail) covalent attachment of Fab fragments on a microparticle, subattomole amounts of PSA can be detected quantitatively.




The following articles in journals at HighWire Press have cited this article:


Home page
Clin. Chem.Home page
P. Tarkkinen, T. Palenius, and T. Lovgren
Ultrarapid, Ultrasensitive One-Step Kinetic Immunoassay for C-Reactive Protein (CRP) in Whole Blood Samples: Measurement of the Entire CRP Concentration Range with a Single Sample Dilution
Clin. Chem., February 1, 2002; 48(2): 269 - 277.
[Abstract] [Full Text] [PDF]




HOME HELP FEEDBACK SUBSCRIPTIONS ARCHIVE SEARCH TABLE OF CONTENTS
Copyright © 2000 by the American Association for Clinical Chemistry.