Clinical Chemistry Link to Randox Laboratories Web Site
HOME HELP FEEDBACK SUBSCRIPTIONS ARCHIVE SEARCH TABLE OF CONTENTS
 QUICK SEARCH:   [advanced]


     


Clinical Chemistry 46: 1338-1344, 2000;
This Article
Right arrow Full Text
Right arrow Full Text (PDF)
Right arrow Submit an electronic Letter to
the Editor about this paper
Right arrow Alert me when this article is cited
Right arrow Alert me when eLetters are posted
Right arrow Alert me if a correction is posted
Right arrow Citation Map
Services
Right arrow Email this article to a friend
Right arrow Similar articles in this journal
Right arrow Similar articles in ISI Web of Science
Right arrow Similar articles in PubMed
Right arrow Alert me to new issues of the journal
Right arrow Download to citation manager
Right arrow reprints & permissions
Citing Articles
Right arrow Citing Articles via HighWire
Right arrow Citing Articles via ISI Web of Science (36)
Right arrow Citing Articles via Google Scholar
Google Scholar
Right arrow Articles by Stiegler, H.
Right arrow Articles by Kunz, D.
Right arrow Search for Related Content
PubMed
Right arrow PubMed Citation
Right arrow Articles by Stiegler, H.
Right arrow Articles by Kunz, D.
Related Collections
Right arrow Laboratory Management
Right arrow Proteomics and Protein Markers
(Clinical Chemistry. 2000;46:1338-1344.)
© 2000 American Association for Clinical Chemistry, Inc.


Articles

Lower Cardiac Troponin T and I Results in Heparin-Plasma Than in Serum

Hugo Stiegler1,a, Yuriko Fischer1, Jaime F. Vazquez-Jimenez3, Jürgen Graf2, Karsten Filzmaier2, Bernd Fausten3, Uwe Janssens2, Axel M. Gressner1 and Dagmar Kunz1

1 Institut für Klinische Chemie und Pathobiochemie,
2 Medizinische Klinik I, and
3 Klinik für Thorax-, Herz- und Gefässchirurgie, Universitätsklinikum der RWTH Aachen, 52074 Aachen, Germany.
a Address correspondence to this author at: Institut für Klinische Chemie und Pathobiochemie, Universitätsklinikum der RWTH Aachen, Pauwelsstrasse 30, 52074 Aachen, Germany. Fax 49-0-241-8888-512; e-mail hugo.stiegler{at}post.rwth-aachen.de

Background: The use of plasma rather than serum for determination of cardiac troponins can improve turnaround time and potentially avoid incomplete serum separation that may produce falsely increased results. We investigated the influence of incomplete serum separation and the effect of heparin-plasma on cardiac troponin concentrations.

Methods: Serum and heparin-plasma samples were drawn simultaneously from 100 patients (50 patients with acute coronary syndrome and 50 patients after open heart surgery) and measured on three different analytical systems, two for determination of cardiac troponin I (cTnI; Abbott AxSYM and Bayer ACS:Centaur) and one for cardiac troponin T (cTnT; Roche Elecsys cTnT STAT). Serum samples were reanalyzed after a second centrifugation to assess the influence of incomplete serum separation.

Results: Mean results (± 95% confidence interval) in heparin-plasma compared with serum were 101% ± 2% (AxSYM cTnI), 94% ± 3% (ACS:Centaur cTnI), and 99% ± 3% (Elecsys cTnT). Differences >20% were seen in 11% of results on the ACS:Centaur, 9% of results on Elecsys cTnT, and 2% of results on the AxSYM. For the Elecsys cTnT assay, the magnitude of the difference between serum and plasma was independent of the absolute concentration and confined to individual samples, and was reversed by treatment with heparinase. A second centrifugation had no effect on serum results by any of the assays.

Conclusion: The concentrations of troponins measured in heparin-plasma are markedly lower than in serum in some cases.




The following articles in journals at HighWire Press have cited this article:


Home page
Ann Clin BiochemHome page
D. C Gaze and P. O Collinson
Multiple molecular forms of circulating cardiac troponin: analytical and clinical significance
Ann Clin Biochem, July 1, 2008; 45(4): 349 - 355.
[Abstract] [Full Text] [PDF]


Home page
Clin. Chem.Home page
F. S. Apple and M. M. Murakami
Cardiac Troponin and Creatine Kinase MB Monitoring during In-Hospital Myocardial Reinfarction
Clin. Chem., February 1, 2005; 51(2): 460 - 463.
[Full Text] [PDF]


Home page
Clin. Chem.Home page
R. F. Salamonsen, H.-G. Schneider, M. Bailey, and A. J. Taylor
Cardiac Troponin I Concentrations, but Not Electrocardiographic Results, Predict an Extended Hospital Stay after Coronary Artery Bypass Graft Surgery
Clin. Chem., January 1, 2005; 51(1): 40 - 46.
[Abstract] [Full Text] [PDF]


Home page
Clin. Chem.Home page
F. S. Apple and M. M. Murakami
Serum 99th Percentile Reference Cutoffs for Seven Cardiac Troponin Assays
Clin. Chem., August 1, 2004; 50(8): 1477 - 1479.
[Full Text] [PDF]


Home page
Clin. Chem.Home page
F. S. Apple, H. E. Quist, P. J. Doyle, A. P. Otto, and M. M. Murakami
Plasma 99th Percentile Reference Limits for Cardiac Troponin and Creatine Kinase MB Mass for Use with European Society of Cardiology/American College of Cardiology Consensus Recommendations
Clin. Chem., August 1, 2003; 49(8): 1331 - 1336.
[Abstract] [Full Text] [PDF]


Home page
DiabetesHome page
C. Anderwald, G. Brabant, E. Bernroider, R. Horn, A. Brehm, W. Waldhausl, and M. Roden
Insulin-Dependent Modulation of Plasma Ghrelin and Leptin Concentrations Is Less Pronounced in Type 2 Diabetic Patients
Diabetes, July 1, 2003; 52(7): 1792 - 1798.
[Abstract] [Full Text] [PDF]


Home page
ChestHome page
M. Panteghini
Acute Coronary Syndrome: Biochemical Strategies in the Troponin Era
Chest, October 1, 2002; 122(4): 1428 - 1435.
[Abstract] [Full Text] [PDF]


Home page
Clin. Chem.Home page
W. J. Kim, O. F. Laterza, K. G. Hock, J. F. Pierson-Perry, D. M. Kaminski, M. Mesguich, F. Braconnier, R. Zimmermann, M. Zaninotto, M. Plebani, et al.
Performance of a Revised Cardiac Troponin Method That Minimizes Interferences from Heterophilic Antibodies
Clin. Chem., July 1, 2002; 48(7): 1028 - 1034.
[Abstract] [Full Text] [PDF]


Home page
Clin. Chem.Home page
D. Peetz, G. Hafner, and K. J. Lackner
Analytical Characteristics of the AxSYM Cardiac Troponin I and Creatine Kinase MB Assays
Clin. Chem., July 1, 2002; 48(7): 1110 - 1111.
[Full Text] [PDF]


Home page
Clin. Chem.Home page
M. Groschl, R. Wagner, J. Dotsch, W. Rascher, and M. Rauh
Preanalytical Influences on the Measurement of Ghrelin
Clin. Chem., July 1, 2002; 48(7): 1114 - 1116.
[Full Text] [PDF]


Home page
Clin. Chem.Home page
D. Uettwiller-Geiger, A. H.B. Wu, F. S. Apple, A. W. Jevans, P. Venge, M. D. Olson, C. Darte, D. L. Woodrum, S. Roberts, and S. Chan
Multicenter Evaluation of an Automated Assay for Troponin I
Clin. Chem., June 1, 2002; 48(6): 869 - 876.
[Abstract] [Full Text] [PDF]


Home page
Clin. Chem.Home page
A. Cerutti, L. Corsini, R. Finotto, and C. Perazzi
Comparison of Cardiac Troponin I in Serum and Heparin Plasma with the Dimension RxL Assay
Clin. Chem., May 1, 2002; 48(5): 790 - 791.
[Full Text] [PDF]


Home page
Clin. Chem.Home page
G. P. Armstrong, A. N. Barker, H. Patel, and H. H. Hart
Reference Interval for Troponin I on the ACS:Centaur Assay: A Recommendation Based on the Recent Redefinition of Myocardial Infarction
Clin. Chem., January 1, 2002; 48(1): 198 - 199.
[Full Text] [PDF]


Home page
JAMAHome page
M. J. Quinn and D. J. Moliterno
Troponins in Acute Coronary Syndromes: More TACTICS for an Early Invasive Strategy
JAMA, November 21, 2001; 286(19): 2461 - 2462.
[Full Text] [PDF]


Home page
Clin. Chem.Home page
G. H. White and P. A. Tideman
Increased Troponin T in a Patient with Dermatomyositis
Clin. Chem., June 1, 2001; 47(6): 1130 - 1131.
[Full Text] [PDF]


Home page
Clin. Chem.Home page
P. Venge, B. Lindahl, and L. Wallentin
New Generation Cardiac Troponin I Assay for the Access Immunoassay System
Clin. Chem., May 1, 2001; 47(5): 959 - 961.
[Full Text] [PDF]


Home page
Clin. Chem.Home page
F. S. Apple and A. H.B. Wu
Myocardial Infarction Redefined: Role of Cardiac Troponin Testing
Clin. Chem., March 1, 2001; 47(3): 377 - 379.
[Full Text] [PDF]


Home page
Clin. Chem.Home page
K. F. Buechler, K. K. Nakamura, W. Gerhardt, G. Nordin, A. Isaksson, S. Haglund, E. Gustavsson, M. Muller-Bardorf, and H. A. Katus
Diagnostic accuracy of an agarose gel electrophoretic method in multiple sclerosis.
Clin. Chem., January 1, 2001; 47(1): 144 - 144.
[Full Text] [PDF]




HOME HELP FEEDBACK SUBSCRIPTIONS ARCHIVE SEARCH TABLE OF CONTENTS
Copyright © 2000 by the American Association for Clinical Chemistry.