Clinical Chemistry AACC Online Job Center
HOME HELP FEEDBACK SUBSCRIPTIONS ARCHIVE SEARCH TABLE OF CONTENTS
 QUICK SEARCH:   [advanced]


     


Clinical Chemistry 51: 901-903, 2005. First published February 25, 2005; 10.1373/clinchem.2004.042051
This Article
Right arrow Full Text
Right arrow Full Text (PDF)
Right arrow All Versions of this Article:
clinchem.2004.042051v1
51/5/901    most recent
Right arrow Submit an electronic Letter to
the Editor about this paper
Right arrow Alert me when this article is cited
Right arrow Alert me when eLetters are posted
Right arrow Alert me if a correction is posted
Right arrow Citation Map
Services
Right arrow Email this article to a friend
Right arrow Similar articles in this journal
Right arrow Similar articles in ISI Web of Science
Right arrow Similar articles in PubMed
Right arrow Alert me to new issues of the journal
Right arrow Download to citation manager
Right arrow reprints & permissions
Citing Articles
Right arrow Citing Articles via ISI Web of Science (2)
Right arrow Citing Articles via Google Scholar
Google Scholar
Right arrow Articles by Vesper, H. W.
Right arrow Articles by Myers, G. L.
Right arrow Search for Related Content
PubMed
Right arrow PubMed Citation
Right arrow Articles by Vesper, H. W.
Right arrow Articles by Myers, G. L.
Related Collections
Right arrow Point-of-Care Testing
Right arrow Drug Monitoring and Toxicology
Right arrow Endocrinology and Metabolism
(Clinical Chemistry. 2005;51:901-903.)
© 2005 American Association for Clinical Chemistry, Inc.


Technical Briefs

Assessment of a Reference Procedure to Collect and Analyze Glucose in Capillary Whole Blood

Hubert W. Vesper1,a, Enada Archibold1, Kimberly H. Porter2 and Gary L. Myers1

1 Centers for Disease Control and Prevention, National Center for Environmental Health, Division of Laboratory Sciences, Clinical Chemistry Branch, Atlanta, GA; 2 Battelle Memorial Institute, Atlanta, GA

aaddress correspondence to this author at: Centers for Disease Control and Prevention, National Center for Environmental Health, Division of Laboratory Sciences, Clinical Chemistry Branch, 4770 Buford Hwy. NE, MS F25, Atlanta, GA 30341-3724; fax 770-488-4192, e-mail hav2@cdc.gov

The first 20% of the full text of this article appears below.

Self-monitoring of blood glucose is used to assist patients with diabetes in achieving and maintaining blood glucose concentrations close to those found in individuals without diabetes. This goal requires that blood glucose monitors meet analytical performance criteria that are appropriate for patient care (1)(2)(3). The lack of accuracy of monitors and the resulting variability among monitors limit their use for assessing and maintaining glycemic control (4)(5).

No suitable means exists for establishing calibration traceability between a glucose monitor and a reference method. In the absence of a whole-blood glucose reference material, the recommended approach to establishing traceability is to perform split-sample comparisons with patient samples and a reference method (6). This can be achieved by following the Clinical and Laboratory Standards Institute (NCCLS) EP9-A2 (7) guideline procedure. Because the capillary whole blood required by these monitors usually is available only in small amounts and because glucose is not stable in this matrix, such split-sample comparison studies are difficult to perform, particularly when specimens need to be transported elsewhere (8). Capillary collection devices have been used in method-comparison studies to characterize glucose monitors (8)(9)(10)(11)(12)(13), but data on the stability and reproducibility of glucose measurements of blood in these capillary collection devices are limited (8)(9). In this study, we assessed a capillary collection procedure in combination with a gas chromatography–mass spectrometry (GC/MS) reference method for measuring glucose in whole blood.

The specimen collection procedure and measurement of glucose by GC/MS were based on a previously published method (9). The specimen collection procedure consisted . . . [Full Text of this Article]