Clinical Chemistry Link to Randox Laboratories Web Site
HOME HELP FEEDBACK SUBSCRIPTIONS ARCHIVE SEARCH TABLE OF CONTENTS
 QUICK SEARCH:   [advanced]


     


Clinical Chemistry 52: 2127-2128, 2006; 10.1373/clinchem.2006.074567
This Article
Right arrow Full Text
Right arrow Full Text (PDF)
Right arrow Submit an electronic Letter to
the Editor about this paper
Right arrow Alert me when this article is cited
Right arrow Alert me when eLetters are posted
Right arrow Alert me if a correction is posted
Services
Right arrow Email this article to a friend
Right arrow Similar articles in this journal
Right arrow Similar articles in ISI Web of Science
Right arrow Similar articles in PubMed
Right arrow Alert me to new issues of the journal
Right arrow Download to citation manager
Right arrow reprints & permissions
Citing Articles
Right arrow Citing Articles via Google Scholar
Google Scholar
Right arrow Articles by Hézard, N.
Right arrow Articles by Nguyen, P.
Right arrow Search for Related Content
PubMed
Right arrow PubMed Citation
Right arrow Articles by Hézard, N.
Right arrow Articles by Nguyen, P.
Related Collections
Right arrow Hemostasis and Thrombosis
Right arrow Hematology
(Clinical Chemistry. 2006;52:2127-2128.)
© 2006 American Association for Clinical Chemistry, Inc.


Letters to the Editor

Reliability of Thrombin Generation Assay on Frozen-Thawed Platelet-Rich Plasma: A Reply

Nathalie Hézard, Marie-Geneviève Remy, Bernadette Florent and Philippe Nguyena

Laboratoire d’Hématologie, CHU Robert Debré, Reims, France

aAddress correspondence to this author at: Laboratoire d’Hématologie, CHU Robert Debré, 51092 Reims Cedex, France. Fax 33-3-26-78-81-71; e-mail pnguyen@chu-reims.fr.

The first 20% of the full text of this article appears below.


To the Editor:

We read with interest the comments of Lippi et al (1) who questioned the reproducibility and difficulty of standardization when we (2) used platelet-rich plasma (PRP) in the thrombin generation assay (TGA). We evaluated the use of TGA to identify patients needing further specific thrombophilic risk factor testing (2). For this, we used frozen-thawed (ft-PRP). PRP was obtained by centrifugation (190g for 12 min), adjusted to 150 x 109/L, and immediately frozen at –80 °C. Samples were immediately thawed before the assay. TGA was triggered by the addition of 0.5 pmol/L of recombinant human . . . [Full Text of this Article]