Clinical Chemistry AACC Online Job Center
HOME HELP FEEDBACK SUBSCRIPTIONS ARCHIVE SEARCH TABLE OF CONTENTS
 QUICK SEARCH:   [advanced]


     


Clinical Chemistry 43: 424-426, 1997;
This Article
Right arrow Extract Freely available
Right arrow Full Text (PDF)
Right arrow Submit an electronic Letter to
the Editor about this paper
Right arrow Alert me when this article is cited
Right arrow Alert me when eLetters are posted
Right arrow Alert me if a correction is posted
Right arrow Citation Map
Services
Right arrow Email this article to a friend
Right arrow Similar articles in this journal
Right arrow Similar articles in ISI Web of Science
Right arrow Similar articles in PubMed
Right arrow Alert me to new issues of the journal
Right arrow Download to citation manager
Right arrow reprints & permissions
Citing Articles
Right arrow Citing Articles via ISI Web of Science (1)
Right arrow Citing Articles via Google Scholar
Google Scholar
Right arrow Articles by Angrist, M.
Right arrow Search for Related Content
PubMed
Right arrow PubMed Citation
Right arrow Articles by Angrist, M.
Related Collections
Right arrow Automation and Analytical Techniques
(Clinical Chemistry. 1997;43:424-426.)
© 1997 American Association for Clinical Chemistry, Inc.


Editorials

Does Phaster Mean Better?

Misha Angrist

Department of Genetics, Case Western Reserve University, 2109 Adelbert Rd. BRB-747B, Cleveland, OH 44106-4955, Fax 216-368-5857, E-mail mhast8{at}chimera.gene.cwru.edu

The accelerated pace of discovery of disease-causing genes has made efficient mutation detection a priority. Identification of DNA sequence variants allows human geneticists to determine, among other things, whether a candidate gene contributes to disease susceptibility, to identify new alleles at known loci, and to develop molecular diagnostic tests. Once a susceptibility gene has been identified, the investigator interested in molecular diagnostics or genotype–phenotype correlation must decide how to perform rapid, sensitive detection of mutations.

Grompe (1) divided these techniques into those that are most useful for identifying known mutations and those that are better for detecting novel mutations. However, he also allowed that no one method would be appropriate for all situations. Clearly, the choices investigators make will be based, in part, on what they are trying to accomplish (e.g., diagnostics vs population studies of allele frequencies); the goal will also dictate the level of sensitivity required and, conversely, the proportion of false positives or negatives that can be tolerated. Other factors such as knowledge of genomic size, sequence, and structure; availability of RNA/cDNA; and access to equipment and technical expertise will also influence the decision.

Since its identification in 1993 and 1994 as the (or, at least, a) major gene responsible for multiple endocrine neoplasia types 2A and 2B (MEN 2A, MEN 2B) and Hirschsprung disease (HSCR), respectively, the RET receptor tyrosine kinase1 has provided a real-time case study of some of the more vexing aspects of both the detection and interpretation of mutations (2)(3)(4)(5)(6)(7). The latter problem, namely, correlating genotype with phenotype, is a fascinating one and has been considered elsewhere (8)(9)(10).

The former issue, determining the best approach to detecting RET mutations for a given set of patients, is easier to deal with, in that it is primarily a technical question. In this issue, Siegelman et al. (11) present an optimized single-strand conformation polymorphism (SSCP) assay performed with the automated Phast SystemTM (Pharmacia Biotech, Piscataway, NJ) for three RET exons. As the authors point out, the ability to detect these mutations has freed clinicians from the more invasive, less reliable pentagastrin test (which increases serum calcitonin concentrations) as a predictor for this set of late-onset diseases, mainly medullary thyroid carcinoma (MTC). The following bears emphasizing: Increased calcitonin concentrations are apparently present in only about half of MTC/MEN2 gene carriers. Moreover, biochemical and clinical evidence of MTC is age-dependent. Thus, given that >92% of MEN2 families have been found to carry a RET mutation (10), identification of gene carriers by direct means offers a more reliable, age-independent alternative to biochemical screening. Although the cost-effectiveness of this may be difficult to quantify (10), the clinical implications are profound: Early diagnosis allows for prophylactic surgery (thyroidectomy and lymph node clearance) with a very high cure rate (12)(13)(14)(15).

Given the size of RET (21 exons coding for a protein with two major isoforms of ~1100 amino acids each) and the difficulty in obtaining RET RNA from germline (nontumor) tissue, scanning genomic DNA (in this case, PCR product) is clearly the way to go. If it were necessary to scan all exons for mutations (as is the case in HSCR), this would be too daunting, even for a small number of patients. However, because the neuroendocrine tumor-associated RET mutations are clustered among the cysteine residues in exons 10 and 11 (and, in the case of MEN 2B, a single methionine codon in exon 16), a simple and rapid assay should be possible.

What are the options for developing such an assay? Unfortunately, because of the variety of nucleotide changes in exons 10 and 11 that alter a small number of cysteine residues, restriction enzyme analysis becomes impractical. Sequencing is certainly sensitive, but relatively labor-intensive and expensive. Denaturing gradient gel electrophoresis (DGGE) is also highly sensitive, but requires a substantial initial investment in electrophoretic apparatus, primers containing long GC clamps, and determination of melting curves for each PCR product. For the laboratory with DGGE already up and running, or one that is prepared to make a long-term commitment to mutation detection, this approach may be the most fruitful, and reliable conditions for RET exons have been developed (16)(17).

What Phast System-based SSCP offers is, in a word, speed. This comes from the system's use of precast gels, buffer strips precast in agarose, short run times (gels are only ~5 cm long), temperature control, and an automated silver-staining chamber. Thus, unlike in conventional SSCP, heteroduplex analysis, DGGE, and other sequencing gel-based detection methods, it is not necessary to pour gels, make buffer, run gels in the cold room, or wrestle with unwieldy staining apparatus—where many a gel has been lost. Moreover, the small scale of the Phast System requires only picogram quantities of PCR product for efficient detection. As for expense, beyond the initial $8000–$9000 for the apparatus, our laboratory has estimated that each RET genotype is obtained at a cost of no more than a few dollars, including DNA isolation and PCR. Clearly, this cost can vary widely, based on the availability and price of reagents and competent technical help. The system is also ideally suited to both denaturing and nondenaturing protein gels. A more compelling case can be made for purchasing the Phast System if a laboratory has a need for both DNA and protein applications. However, the present discussion is limited to the merits of Phast-based SSCP.

As stated, although the common MEN 2B mutation in exon 16 (M918T) removes a Fok I site and could therefore be easily analyzed by restriction digest, exons 10 and 11 harbor a variety of mutations in multiple codons in MEN 2A and MTC patients (see Table 1 in reference 11). The Phast approach is particularly appropriate for this type of situation, i.e., where a large number of mutations are clustered among a small number of exons. Indeed, as Siegelman et al. point out, the system is a simple, rapid, and relatively inexpensive alternative to DGGE and conventional isotopic methods. Given the important decisions that must be made in light of a diagnosis of MEN2, this type of rapid mutation detection will undoubtedly continue to have great clinical utility.

Certainly, no mutation detection system is perfect, and the Phast System is no exception. One general problem with SSCP is that the assay provides no information as to the exact nature of the sequence variation. Clearly, for diagnostic purposes and genotype–phenotype correlations, sequencing is still an essential final step. Another limitation is sensitivity which, in our hands, fell well short of the 95% found by Siegelman et al. (11). Subsequent to our Phast-based mutation screen of the entire length of RET among HSCR patients (2), which detected 8 mutations, an additional 4 sequence variants were found by DGGE and (or) sequencing (R.M.W. Hofstra, S. Bolk, M. Angrist, C.H.C.M. Buys, and A. Chakravarti, unpublished data). This implies a detection rate of <70%. We are not a clinical laboratory and do not demand 100% detection, but still, for a large family with a linked haplotype, it is very frustrating not to be able to find a mutation, short of sequencing every exon. Also, false negatives make determination of genotype–phenotype correlations much slower. Like Siegelman et al. (11), we also tried two temperature conditions (2). Some investigators will use as many as four conditions to increase sensitivity (R.G.H. Cotton, personal communication). Of course, this adds to the cost and defeats the stated purpose of maximizing efficiency. The sensitivity problem may be more relevant for HSCR, where mutations are distributed throughout the coding sequence (8), than for MEN2, where mutations are found in only a few exons.

Second, as convenient as it is, the Phast System could be much more so. As currently configured, the System can accommodate no more than 24 samples. Thus, short of purchasing two machines, one can analyze in a single loading only 1/2 to 1/3 the number of samples that can be fit on a full-size sequencing gel (with a 48- or 72-well comb, respectively). For a diagnostic laboratory that does not require high throughput, this may not be an issue. But for laboratories performing large numbers of analyses on controls, patients, and their families, turnaround time could be greatly enhanced by increasing the sample capacity. Also, my colleagues and I have found that after a while the separation control unit (where the gels sit during electrophoresis) no longer cools to 4 °C. After consulting with the manufacturer, we were still not able to overcome this problem and settled for analyses at 8 °C. As the report in this issue demonstrates (11), temperature variation can have a significant impact on sensitivity. By conceding the use of temperatures below 8 °C, we may have missed some mutations.

Finally, in my opinion, Pharmacia would do well to adapt the Phast System for use with novel mutation detection methods, of which there is no shortage. In particular, I am thinking of the enzyme mismatch cleavage (EMC) method developed by Cotton's group (18) and the Cleavase® system (Third Wave Technologies, Madison, WI). Both methods use endonucleases that cleave perturbations in DNA conformation so as to distinguish between wild-type and mutant species. EMC is based on the recognition of mismatches, whereas Cleavase recognizes (and cuts) specific types of single-stranded DNA conformers as generated by SSCP. The two methods share several advantages: They are highly sensitive, are no more labor-intensive than ordinary SSCP, and, best of all, can be used to analyze fragments of >1 kb—some two- to fourfold longer than SSCP or DGGE. SSCP in particular is most sensitive when applied to fragments of ~150 bp (19). Both the EMC and Cleavase methods would be readily amenable to Phast System analysis except for the lack of commercially available acrylamide Phastgels containing urea to act as a denaturant. Using the currently available nondenaturing gels, the Phast System cannot run at a sufficiently high temperature to maintain the samples in their denatured state. Denaturing conditions are undesirable for the nondenaturing technique of SSCP but are essential for the newer methods. The optimization of these approaches for automated electrophoresis and silver-staining—which would also make end-labeling superfluous (although at the cost of knowing the exact location of the mutation)—would provide mutation hunters with another easy, nonradioactive entrée into the state-of-the-art.

A final caveat: This so-called state-of-the-art is changing in a hurry, so the mutation detection debate may soon be relegated to the history books. Enterprising biotechnologists at Affymetrix (Santa Clara, CA) have figured out how to array 104 or more oligonucleotides on silicon supports. By cohybridizing reference and test samples against these arrays and quantifying differences in hybridization patterns, one can scan huge genomic regions for all possible heterozygous mutations. This approach has recently been applied to the human mitochondrial genome and the familial early-onset breast cancer gene, BRCA1, with impressive results (20)(21). We can now dare to imagine extremely rapid, inexpensive, and automated mutation detection on a vast scale and, best of all, in a gel-free world. Amen!


Acknowledgments

I thank Aravinda Chakravarti for his support over the years. Studies of RET and Hirschsprung disease in his laboratory are supported by NICHD HD 28088. I am grateful to R.G.H. Cotton for critically reading the manuscript and to an anonymous reviewer for helpful comments. Our work would not be possible without the countless Hirschsprung and neurocristopathy patients who have participated in our studies and the contributions of Stacey Bolk, Robert M.W. Hofstra, and Charles H.C.M. Buys.


Footnotes

1 I am biased, but I prefer this designation to the more popular "RET protooncogene" because we now know that RET is much more than the cellular version of a cancer susceptibility gene; it has critical roles in kidney and gut development. "Receptor tyrosine kinase" is a neutral term describing what the protein is (a receptor) and its generic cellular function (to phosphorylate tyrosine residues), without making reference to disease phenotype.


References

  1. Grompe M. The rapid detection of unknown mutations in nucleic acids. Nature Genet 1993;5:111-117. [ISI][Medline] [Order article via Infotrieve]
  2. Angrist M, Bolk S, Thiel B, Puffenberger EG, Hofstra RM, Buys CHCM, et al. Mutation analysis of the RET receptor tyrosine kinase in Hirschsprung disease. Hum Mol Genet 1995;4:821-830. [Abstract/Free Full Text]
  3. Donis-Keller H, Dou S, Chi D, Carlson KM, Toshima K, Lairmore TC, et al. Mutations in the RET proto-oncogene are associated with MEN2A and FMTC. Hum Mol Genet 1993;2:851-856. [Abstract/Free Full Text]
  4. Edery P, Lyonnet S, Mulligan LM, Pelet A, Dow E, Abel L, et al. Mutations of the RET proto-oncogene in Hirschsprung's disease. Nature 1994;367:378-380. [Medline] [Order article via Infotrieve]
  5. Hofstra RMW, Landsvater RM, Ceccherini I, Stulp RP, Stelwagen T, Luo Y, et al. A mutation in the RET proto-oncogene associated with multiple endocrine neoplasia type 2B and sporadic medullary thyroid carcinoma. Nature 1994;367:375-376. [Medline] [Order article via Infotrieve]
  6. Mulligan LM, Kwok JBJ, Healey CS, Elsdon MJ, Eng C, Gardner E, et al. Germ-line mutations of the RET proto-oncogene in multiple endocrine neoplasia type 2A. Nature 1993;363:458-460. [Medline] [Order article via Infotrieve]
  7. Romeo G, Ronchetto P, Luo Y, Barone V, Seri M, Ceccherini I, et al. Point mutations affecting the tyrosine kinase domain of the RET proto-oncogene in Hirschsprung's disease. Nature 1994;367:377-378. [Medline] [Order article via Infotrieve]
  8. Chakravarti A. Endothelin receptor-mediated signaling in Hirschsprung disease. Hum Mol Genet 1996;5:303-307. [ISI][Medline] [Order article via Infotrieve]
  9. Pasini B, Ceccherini I, Romeo G. RET mutations in human disease. Trends Genet 1996;12:138-144. [ISI][Medline] [Order article via Infotrieve]
  10. Eng C, Clayton D, Schuffenecker I, Lenoir G, Cote G, Gagel RF, et al. The relationship between specific RET proto-oncogene mutations and disease phenotype in multiple endocrine neoplasia type 2. JAMA 1996;276:1575-1579. [Abstract]
  11. Siegelman M, Mohabeer A, Fahey TJ, Tomlinson G, Mayambala C, Jafari S, et al. Rapid, nonradioactive screening for mutations in exons 10, 11, and 16 of the RET protooncogene associated with inherited medullary thyroid carcinoma. Clin Chem 1997;43:453-457. [Abstract/Free Full Text]
  12. Frilling A, Dralle H, Eng C, Raue F, Broelsch CE. Presymptomatic DNA screening in families with multiple endocrine neoplasia type 2 and familial medullary thyroid carcinoma. Surgery 1995;118:1099-1103. [ISI][Medline] [Order article via Infotrieve]
  13. Marsh DJ, Learoyd DL, Robinson BG. Medullary thyroid carcinoma: recent advances and management update [Review]. Thyroid 1995;5:407-424. [ISI][Medline] [Order article via Infotrieve]
  14. Pacini F, Romei C, Miccoli P, Elisei R, Molinaro E, Mancusi F, et al. Early treatment of hereditary medullary thyroid carcinoma after attribution of multiple endocrine type 2 gene carrier status by screening for ret gene mutations. Surgery 1995;118:1031-1035. [ISI][Medline] [Order article via Infotrieve]
  15. Skinner MA, DeBenedetti MK, Moley JF, Norton JA, Wells SA, Jr. Medullary thyroid carcinoma in children with multiple endocrine neoplasia types 2A and 2B. J Pediatr Surg 1996;31:177-181. [ISI][Medline] [Order article via Infotrieve]
  16. Attié T, Pelet A, Edery P, Eng C, Mulligan LM, Amiel J, et al. Diversity of RET proto-oncogene mutations in familial and sporadic Hirschsprung disease. Hum Mol Genet 1995;4:1381-1386. [Abstract/Free Full Text]
  17. Blank RD, Sklar CA, Martin ML. Denaturing gradient gel electrophoresis to diagnose multiple endocrine neoplasia type 2. Clin Chem 1996;42:598-603. [Abstract/Free Full Text]
  18. Youil R, Kemper BW, Cotton RGH. Screening for mutations by enzyme mismatch cleavage with T4 endonuclease VII. Proc Natl Acad Sci U S A 1995;92:87-91. [Abstract/Free Full Text]
  19. Sheffield VC, Beck JS, Kwitek AE, Sandstrom DW, Stone EM. The sensitivity of single-strand conformation polymorphism analysis for the detection of single base substitutions. Genomics 1993;16:325-332. [ISI][Medline] [Order article via Infotrieve]
  20. Chee M, Yang R, Hubbell E, Berno A, Huang XC, Stern D, et al. Accessing genetic information with high-density DNA arrays. Science 1996;274:610-614. [Abstract/Free Full Text]
  21. Hacia JG, Brody LC, Chee MS, Fodor SPA, Collins FS. Detection of heterozygous mutations in BRCA1 using high density oligonucleotide arrays and two-colour fluorescence analysis. Nature Genet 1996;14:441-447. [ISI][Medline] [Order article via Infotrieve]




This Article
Right arrow Extract Freely available
Right arrow Full Text (PDF)
Right arrow Submit an electronic Letter to
the Editor about this paper
Right arrow Alert me when this article is cited
Right arrow Alert me when eLetters are posted
Right arrow Alert me if a correction is posted
Right arrow Citation Map
Services
Right arrow Email this article to a friend
Right arrow Similar articles in this journal
Right arrow Similar articles in ISI Web of Science
Right arrow Similar articles in PubMed
Right arrow Alert me to new issues of the journal
Right arrow Download to citation manager
Right arrow reprints & permissions
Citing Articles
Right arrow Citing Articles via ISI Web of Science (1)
Right arrow Citing Articles via Google Scholar
Google Scholar
Right arrow Articles by Angrist, M.
Right arrow Search for Related Content
PubMed
Right arrow PubMed Citation
Right arrow Articles by Angrist, M.
Related Collections
Right arrow Automation and Analytical Techniques


HOME HELP FEEDBACK SUBSCRIPTIONS ARCHIVE SEARCH TABLE OF CONTENTS