Clinical Chemistry AACC Online Job Center
HOME HELP FEEDBACK SUBSCRIPTIONS ARCHIVE SEARCH TABLE OF CONTENTS
 QUICK SEARCH:   [advanced]


     


Clinical Chemistry 44: 906-913, 1998;
This Article
Right arrow Abstract Freely available
Right arrow Full Text (PDF)
Right arrow Submit an electronic Letter to
the Editor about this paper
Right arrow Alert me when this article is cited
Right arrow Alert me when eLetters are posted
Right arrow Alert me if a correction is posted
Right arrow Citation Map
Services
Right arrow Email this article to a friend
Right arrow Similar articles in this journal
Right arrow Similar articles in PubMed
Right arrow Alert me to new issues of the journal
Right arrow Download to citation manager
Right arrow reprints & permissions
Citing Articles
Right arrow Citing Articles via HighWire
Right arrow Citing Articles via ISI Web of Science (16)
Right arrow Citing Articles via Google Scholar
Google Scholar
Right arrow Articles by Gelfi, C.
Right arrow Articles by Cremonesi, L.
Right arrow Search for Related Content
PubMed
Right arrow PubMed Citation
Right arrow Articles by Gelfi, C.
Right arrow Articles by Cremonesi, L.
Related Collections
Right arrow Molecular Diagnostics and Genetics
Right arrow Automation and Analytical Techniques
(Clinical Chemistry. 1998;44:906-913.)
© 1998 American Association for Clinical Chemistry, Inc.


Molecular Diagnostics and Genetics

Rapid capillary zone electrophoresis in isoelectric histidine buffer: high resolution of the poly-T tract allelic variants in intron 8 of the CFTR gene

Cecilia Gelfi1, Marilena Perego2, Pier Giorgio Righetti2, Silvia Cainarca3, Stefania Firpo4, Maurizio Ferrari4, and Laura Cremonesi4,a

1 Instituto Di Technologie Biomedicrye, Consiglio Nazionale delle Ricerche, 20032 Segrate Milan, Italy.

2 Università di Verona, Faculty of Science, 37134 Verona, Italy.

3 Telethon Institute of Genetics and Medicine, Biomedical Science Park, H.S. Raffaele, Milan, Italy.

4 Instituto Di Ricovero E Cura A Carattere Scientifico, Unit of Genetics and Molecular Biology, H.S. Raffaele, Milan, Italy.
a Author for correspondence. Fax 39-2-26434779; e-mail cremonl{at}dibit.hsr.it.


   Abstract
Top
Abstract
Introduction
Materials and Methods
Results and Discussion
References
 
The poly-T tract in intron 8 of the cystic fibrosis conductance transmembrane regulator (CFTR) gene exists in three variants, 5T, 7T, and 9T. The 7T and 9T variants generate a predominantly normal transcript, whereas the 5T variant engenders an anomalous product. The analysis of the poly-T tract is assuming increasing relevance, both to assess the implication of the CFTR gene in congenital bilateral absence of the vas deferens and to evaluate genotype-phenotype correlation in cystic fibrosis. Mapping of the poly-T tract has been performed by cumbersome and time-consuming methodologies. Capillary zone electrophoresis, combined with laser-induced fluorescence detection, was introduced for a rapid separation of the poly-T tract amplified products. As separation buffer, we adopted 200 mmol/L histidine (pH = pI = 7.6), and the capillary was filled with 10% polyacrylamide, allowing separations in less than 10 min. Capillary zone electrophoresis results were in perfect agreement with dot-blot analysis.


   Introduction
Top
Abstract
Introduction
Materials and Methods
Results and Discussion
References
 
The poly-T tract located in the acceptor splicing site of intron 8 of the cystic fibrosis transmembrane conductance regulator (CFTR)1 gene exists in three allelic variants, 5T, 7T, and 9T (1). The 7T and 9T variants generate a predominantly normal CFTR transcript, whereas the 5T variant affects splicing efficiency and generates a high proportion of exon 9-skipped CFTR transcripts that engender an anomalous protein product (1). The analysis of the poly-T tract is assuming increasing diagnostic relevance, both to assess the implication of the CFTR gene in congenital bilateral absence of the vas deferens (CBAVD) and to evaluate genotype-phenotype correlation in cystic fibrosis (CF). CBAVD is an autosomal recessive disorder accounting for about 1–2% of male infertility (2). Although CBAVD is present in the majority of CF males, male patients presenting with isolated CBAVD do not exhibit any of the clinical symptoms characteristic of CF (3). The CF phenotype is characterized by lung disease and/or pancreatic exocrine insufficiency, and almost all male and female patients show failure of reproductive function. The relationship between male sterility in CBAVD and CF patients has been extensively studied at the molecular level to determine the molecular spectrum of mutations involved in this syndrome. A large proportion of isolated CBAVD patients carry either a CF mutation and/or the 5T variant of the poly-T tract in intron 8 in at least one of their CFTR genes (4)(5)(6)(7)(8)(9)(10)(11)(12)(13)(14)(15), supporting the hypothesis that CBAVD represents a mild, primary genital form of CF (4). More recently, a correlation between the number of unaffected transcripts and the severity of lung disease in CF patients was found, because it was shown that the amount of exon 9 skipping in respiratory epithelial cells correlates with the severity of the pulmonary disease. Moreover, it was shown that the number of unaffected CFTR transcripts transcribed from the 5T allele may be variable among different individuals and different organs of the same individuals (16). These data indicate that the amount of unaffected CFTR splicing transcribed from the 5T allele is tissue-specific and that the 5T allele may be associated with variable clinical presentation–from healthy fertile males or CBAVD, to typical CF patients–resulting from variable amounts of exon 9 skipping. Also, our study on a sample of CBAVD patients showed that the frequency of the 5T allele among these subjects is markedly higher than that found in a population of unaffected and CF chromosomes, confirming the implication of the CFTR gene in the pathogenesis of CBAVD.

Until now, mapping of the poly-T tract has been performed with various classical methods, including denaturing gradient gel electrophoresis and direct sequencing (9), dot-blot hybridization with radiolabeled allele-specific oligonucleotides (13), silver-stained, nondenaturing polyacrylamide sequencing format gels (16), single-strand conformation polymorphism analysis and direct sequencing (17), heteroduplex analysis (17), and restriction digestion of the PCR product followed by polyacrylamide gel electrophoresis (8), which are cumbersome and/or time-consuming methodologies. The increasing relevance that the poly-T tract in the CFTR gene is assuming in genotype-phenotype correlation in CF and other CF-related syndromes strongly demands the setting up of a new fast and automatable method.

Capillary zone electrophoresis (CZE) is one of the most promising techniques for performing rapid and reproducible separations of DNA. Compared with conventional slab gel electrophoresis, CZE presents the advantage of automation, gives qualitative and quantitative results, offers high resolution, rapid analysis, low reagent consumption, and minute sample requirement. Several applications have been described using CZE for nucleic acid analysis in mutation detection (18)(19)(20)(21)(22), disease diagnosis (23)(24)(25)(26)(27), forensic investigations (28)(29)(30)(31)(32)(33), and PCR-amplified product quantitation (34)(35)(36)(37)(38). Separation by CZE has been achieved by using entangled sieving matrices such as hydroxypropylmethylcellulose, hydroxyethylcellulose, or non-cross-linked polyacrylamide (39)(40)(41). In our opinion, viscous solutions of linear polyacrylamide are to be preferred because they offer a vast range of chain lengths, are able to exert sieving over a large interval of DNA fragments lengths, and can either be polymerized in situ from nonviscous solutions of monomers to produce extremely viscous entangled solutions or dissolved directly in separation buffer after prepolymerization and purification (40).

The difficulty in resolving polymorphic DNA regions containing small repeated sequences depends on the size and base composition of the sequence motif. Generally, the longer and more heterogeneous the base composition of the repeated motif, the easier the resolution in a given separation medium. In the past, we set up simplified methods for analyzing by CZE DNA regions containing tetra- (42) and trinucleotide (43) polymorphic repeats, where analysis of double-stranded DNA PCR products was carried out in TBE buffer. Finally, we drew our attention to the resolution of dinucleotide motifs, such as the poly-T tract variants in intron 8 of the CFTR gene, where we could not use the TBE system because it is not the most suitable for resolving double-stranded DNA fragments differing by the same base pair doublet (TT) from each other.

The aim of this study was to develop a fast, reproducible, and efficient protocol for analyzing poly-T tract variants. Recently, analysis of a polyadenine tract of the transforming growth factor-ß type II receptor gene in colorectal cancers has been reported, where one or two base deletions of the (A)10 repeat could be detected on single-stranded DNA amplified by an asymmetric PCR and resolved by non-gel-sieving capillary electrophoresis (44). This system allowed the best peak separation at 500 V/cm within 30 min, under ultraviolet detection.

In a continuing effort to improve resolution by exploring new matrices and buffering systems, we recently focused on single-stranded oligonucleotide separations by adopting a new isoelectric buffering system, histidine (His) free base. In this system, we could apply as much as 800-1000 V/cm, thus favoring high resolution, allowing much reduced transit times and improved robustness of the separation column. Because of the quasi-neutral pH of His buffer, these columns can be reutilized hundreds of times while still maintaining a high reproducibility (45)(46).

Taking advantage of our last experience on separations in isoelectric buffers, we developed a method for a rapid typing of short double-stranded DNA molecules, differing by as little as the same 2-bp unit. As a model of a difficult separation, we applied this system to analyze the poly-T tract allelic variants located in intron 8 of the CFTR gene, where the use of such buffering system has been coupled with fluorescently labeled primers to obtain an extraordinary increment of sensitivity by laser-induced fluorescence (LIF) detection (47)(48)(49).


   Materials and Methods
Top
Abstract
Introduction
Materials and Methods
Results and Discussion
References
 
reagents
Acrylamide, ammonium peroxidisulfate, and N,N,N',N'-tetramethylethylen-diamine were obtained from Bio-Rad. His was from Sigma Chemical. Fused silica capillaries (100 µm i.d., 375 µm o.d.) were from Polymicro Technologies. Marker V was from Boehringer Mannheim, the 10-bp marker was from Life Technologies, Centricon 10 membranes from Millipore, recombinant Dynazyme II polymerase from Finnzyme Oy, and dNTPs from Pharmacia.

dot-blot hybridization with radiolabeled allele-specific oligonucleotides
For the first PCR, PCR amplification of the poly-T tract in intron 8 of the CFTR gene used primer 9i-5', 5'-TAATGGATCATGGGCCATGT-3', and primer 9i-3', 5'-ACAGTGTTGAATGTGGTGCA-3' (50). The PCR conditions were as follows: 1 min at 94 °C, 1 min at 56 °C, and 1 min at 72 °C. The product length was 560 bp.

Primers for the second semi-nested PCR were primer 9i-5' and 9e-3' (5'-AGAAGAGGCTGTCATCACCA-3'). The same conditions as for first PCR were used, with 1 µL of the first PCR reaction as template. The PCR product length was 207 bp.

The reaction mixture for all amplifications contained 20 pmol of primers, 200 µmol/L dNTPs, 10 mmol/L Tris-HCl, 50 mmol/L KCl, 1.5 mmol/L MgCl2, 1 g/L Triton X-100, and 2 U of Taq polymerase for 100 µL final volume.

For the dot blot, 2 µL of the second PCR reaction was denatured, blotted onto a nylon membrane, and hybridized with 5'-end labeled allele-specific oligonucleotides complementary to the sequence containing five thymidines (5'-TGTGTGTGTTTTTAACAG-3'), seven thymidines (5'-TGTGTGTTTTTTTAACAG-3'), or nine thymidines (5'-GTGTGTTTTTTTTTTAACAG-3'), respectively (13) (Fig. 1 ).



View larger version (40K):
[in this window]
[in a new window]
 
Figure 1. Analysis of the poly-T tract variants by dot-blot ASO hybridization.

(Top) Sequence of intron 8 containing the poly-T tract (underlined). (Bottom) An example of hybridization is shown. Left, numbers indicate the position of each amplified DNA sample spotted on the nylon strips. Right, the ASO used as hybridization probe is shown. Patient 1, genotype 5T/9T; patient 2, genotype 5T/9T; patient 3, genotype 7T/9T; patient 4, genotype 7T/9T; patient 5, genotype 7T/7T; patient 6, genotype 7T/9T.

cze in amphoteric buffer of pcr amplified products
For PCR amplification of the poly-T tract in intron 8 of the CFTR gene, the first PCR used primers 9i-5' and 9i-3'. The template was 400 ng of genomic DNA. The cycling conditions were as follows: 5 min at 94 °C for 1 cycle; 45 s at 94 °C, 45 s at 62 °C, 45 s at 72 °C for 5 cycles, 45 s at 94 °C, 45 s at 60 °C, 45 s at 72 °C for 19 cycles, 45 s at 94 °C, 45 s at 60 °C, and 10 min at 72 °C for 1 cycle. The product length was 560 bp. The reaction mixture for 100 µL final volume was 20 pmol of primers, 200 µmol/L dNTPs, 10 mmol/L Tris-HCl, 50 mmol/L KCl, 1.5 mmol/L MgCl2, 1 g/L Triton X-100, and 2 U of Taq polymerase.

For the second nested PCR, the primers used were forward primer 19D9, 5'-CCGCCGCTGTGTGTGTGTGTGTGTTTTT-3' (7), and reverse primer, 5' labeled with carboxyfluorescein: 5'-GCTTTCTCAAATAATTCCCC-3'. The template was 1 µL of an 1/300 aliquot of the first PCR. Cycling conditions were 5 min at 94 °C for 1 cycle, 45 s at 94 °C, 45 s at 62 °C, 45 s at 72 °C for 3 cycles, 45 s at 94 °C, 45 s at 60 °C, 45 s at 72 °C for 3 cycles, 45 s at 94 °C, 45 s at 58 °C, 45 s at 72 °C for 18 cycles, 45 s at 94 °C, 45 s at 58 °C, and 10 min at 72 °C for 1 cycle. The product length was 59 bp for the fragment amplified from alleles carrying the 5T variant, 61 bp from the 7T variant, and 63 bp from the 9T variant.

Reaction mixture for 100 µL final volume was: 30 pmol of primers, 200 µmol/L dNTPs, 10 mmol/L Tris-HCl, 50 mmol/L KCl, 1.5 mmol/L MgCl2, 0.1% Triton X-100, and 2 U of Taq polymerase.

CZE was performed in a Bio Focus 3000 LIF 2 instrument equipped with a LIF detector providing 488-nm excitation with 520-nm bandpass filter (Bio Rad). To eliminate electroendosmosis, a Beckman-coated capillary was used. The capillary (100 µm i.d., 375 µm o.d.) was 27 cm long with a detection window at 7 cm from the outlet, from which the injections were done. As separation buffer of 200 mmol/L His was used, and the capillary was filled with 6% or 10% polyacrylamide polymerized in situ. The Marker V and the 10-bp marker were run in a 6% polyacrylamide, injected for 5 s electrokinetically, and detected by ultraviolet light at 254 nm. After desalting with the Centricon 10 membrane, the sample was injected electrokinetically for 30 s at 8 KV, and separation was made at 150 V/cm. The running temperature was set at 25 °C.


   Results and Discussion
Top
Abstract
Introduction
Materials and Methods
Results and Discussion
References
 
We evaluated the poly-T distribution in cystic fibrosis (CF) and unaffected chromosomes in 76 families having a CF child by dot-blot hybridization with radiolabeled allele-specific oligonucleotides (Fig. 1Up ). Among CF chromosomes, the 5T, 7T, and 9T variants had a 1%, 51%, and 48% frequency, respectively, and among unaffected chromosomes, 3%, 84%, and 13%, respectively. Among the 19 CBAVD subjects investigated (of the 38 chromosomes analyzed), 8 (21%) carry the 5T variant, 19 (50%) the 7T variant, and 11 (29%) the 9T variant.

Typing of the poly-T tract in intron 8 of the CFTR gene in CBAVD subjects showed an increased proportion of the 5T variant in these subjects. The frequency of the 5T allele in CBAVD subjects (21%) is significantly different from that found in unaffected chromosomes (3%; Fisher's exact test: P = 0.0008, not corrected) and in CF chromosomes (1%; Fisher's exact test: P = 0.001, not corrected), thus confirming the implication of CFTR abnormalities in the pathogenesis of CBAVD.

optimization of pcr conditions
Because of the extremely high sensitivity of the CZE system coupled with LIF detection, the greatest problem we encountered in setting up the poly-T amplification was to avoid the appearance of spurious bands in the amplified product because of primer mispairing, which can seriously affect genotypic interpretation. To analyze the poly-T tract in intron 8 of the CFTR gene, we used a nested PCR procedure because the (GT) tract immediately preceding is also polymorphic with respect to the length (Fig. 1Up ). To optimize specificity, we used two strategies: (a) We used 1 µL of a 300-fold dilution of the first PCR reaction as template for the nested PCR reaction and (b) we used a simplified version of the "Touchdown" PCR strategy (51), named "Stepdown" PCR (52), by performing an initial set of a few cycles at an annealing temperature 4-6 °C higher than the targeted annealing temperature calculated from the melting temperature (Tm) of the primer pairs used (denaturation at 94 °C for 45 s, annealing at 62° for 45 s, and extension at 72 °C for three cycles for the first PCR reaction; denaturation at 94 °C for 45 s, annealing at 62° for 45 s, and extension at 72 °C for three cycles, denaturation at 94 °C for 45 s, annealing at 60° for 45 s, and extension at 72 °C for an additional three cycles for the nested PCR reaction) and subsequently decreasing the annealing temperature to the targeted one for each set of primers for the remaining cycles (denaturation at 94 °C for 45 s, annealing at 60° for 45 s, and extension at 72 °C for 19 cycles for the first PCR reaction; denaturation at 94 °C for 45 s, annealing at 58 °C for 45 s, and extension at 72 °C for 18 cycles for the nested PCR reaction). A final cycle including prolonged extension (10 min at 72 °C) was added to both PCR assays. This strategy, coupled with the use of nested primers, gave the expected 59-, 61-, and 63-bp products for the 5T, 7T, and 9T alleles, respectively, indicating that the appropriate target was amplified, without any aspecific additional band. As shown in Figs. 5 and 6 , products within the allelic size difference of 5T-9T can be determined unambiguously on all CZE tracings.



View larger version (15K):
[in this window]
[in a new window]
 
Figure 5. Analysis of poly-T tract of patient 2 with genotype 5T/9T.

The sample was injected electrokinetically for 30 s at 8 KV, and the separation was at 200 V/cm in 10% polyacrylamide polymerized in situ. RFU, reference fluorescence unit.



View larger version (12K):
[in this window]
[in a new window]
 
Figure 6. Electropherograms of five patients representative of genotypes found in our cohort of chromosomes.

Patient 1, genotype 5T/9T (5)(9); patient 2, genotype 5T/7T (5)(7); patient 3, genotype 7T/9T (7)(9); patient 4, genotype 9T/9T (9)(9); patient 5, genotype 7T/7T (7)(7). Experimental conditions are as in Fig. 5Up . RFU, reference fluorescence unit.

optimization of cze conditions
The use of isoelectric buffers in CZE was first described by Hjertén et al. (53), and the application to oligonucleotide separation was largely investigated by our group (45)(46). By using amphoteric buffers, we could assess the purity of antisense oligonucleotides in 5 minutes with high resolution by combining very low conductivity together with satisfactory buffering capacity. For oligonucleotide separation, His showed the best resolution compared with lysine or ampholytes, even if its buffering power was lower. His is an amino acid having three dissociative groups with the following pKs: 1.8 (R-COOH), 6.1 (side chain), and 9.2 (R-NH3). Because the two highest pKs are rather close, His has reasonably good buffer capacity at its pI. Considering the pK of the side chain and NH3, the pI of His is 7.65, well compatible with the range of stability and full dissociation of DNA.

When dissolved in water, the solution is mainly composed of the zwitterionic species, together with a smaller amount of the cationic and anionic species. Such a solution has a very low conductivity, and the current is carried only by the minute amount of non isoelectric species, involving a minimum heating also when applying high voltages. The pI of 7.65 reduces the hydrolysis rate of the polyacrylamide, used both for coating and for sieving, thus allowing a repetitive use of the matrix and consequently increasing the number of assays with the same capillary without loss of reproducibility. These properties make His a good candidate for DNA separations, and we decided to investigate its performance in double-stranded DNA separations. In fact, although it is well known that single-stranded DNA separations allow single base resolution up to at least 300 bases (as in DNA sequencing), it must be emphasized that (a) sieving liquid polymers, as adopted in CZE, do not permit such a high resolution as that obtained in cross-linked polyacrylamide gel matrices and (b) double-stranded DNA separations allow the use of fluorescent intercalators without any need of covalently labeling the primers, as typical of single-stranded DNA analysis.

We investigated the increase in buffer concentration related to the separation of marker V, which presents fragments ranging from 8 to 587 bp. By using buffer concentrations ranging from 50 to 300 mmol/L His we observed, as shown in Fig. 2 , that the best resolving power was at 200 mmol/L His with an increase in resolution from 8 to 130 bp and the concomitant separation of the 123/124-bp doublet, which is usually achieved only in the presence of ethidium bromide as intercalating agent. In all cases, however, we completely lost resolution above 130 bp. To determine the optimal His concentration, we focused on optimizing the separation of the 57-bp vs 64-bp peaks of the previously shown marker V, because this is our range of interest. By plotting the resolution (Rs) vs His molarity, as shown in Fig. 3 , we observed that the best resolving power was at 200 mmol/L His. Moreover, we confirmed the resolving power increment, within the region of interest, by analyzing a 10-bp marker in the presence of 8% linear polyacrylamide and 200 mmol/L His; as shown in Fig. 4 , we had high resolution, even of the products of spurious markers, because of incomplete synthesis, up to 100 bp.



View larger version (18K):
[in this window]
[in a new window]
 
Figure 2. Separation of double-stranded DNA marker V in 200 mmol/L His, pH 7.5, in 6% acrylamide polymerized in situ is shown.

The capillary was 37 cm long, the separation was at 200 V/cm, the sample was injected electrokinetically for 5 s at 200 V/cm, and detection was at 254 nm.



View larger version (10K):
[in this window]
[in a new window]
 
Figure 3. Plots of resolution (Rs) vs His molarity.

The resolution refers to the doublet 57 bp vs 64-bp double-stranded DNA fragments of marker V. CZE separation conditions were as in Fig. 2Up .



View larger version (15K):
[in this window]
[in a new window]
 
Figure 4. Separation of double-stranded DNA 10-bp interval ladder marker.

Capillary electrophoretic conditions were as in Fig. 2Up .

Concerning the resolution increment in double-stranded DNA up to the 130-bp length, we think that the mechanism could be an interaction between His and DNA via coulombic attractions and consequent modification of the DNA radius of gyration (46). Recent data (Gelfi et al., unpublished) have shown that the addition of competing cations (e.g., K in KBr and Na in NaCl), even at the concentration of 10 mmol/L, completely obliterates the effects of the His buffer, suggesting that the smaller cations can effectively compete on binding sites on the DNA double helix. We hypothesize that His could bind via coulombic interaction with the phosphate groups by forming a bidentate ionic complex with the two positive groups (imidazole and alpha-amino, which both bear half-positive charge at pH = pI). His could thus be oriented so as to offer the two half-positive charges to the phosphate, while keeping the fully dissociated carboxyl group in a distal position.

Taking into account these findings, we developed a protocol that presents the advantage of rapidly genotyping short DNA-amplified fragments as in the poly-T tract by using CZE in polymer networks, His as separating buffer, and LIF detection. In comparison with the other techniques used thus far to analyze the poly-T tract variants, this protocol is more rapid and nonradioactive. Fig. 5Up shows the separation of an amplified fragment with genotype 5/9 in 10% polyacrylamide and 200 mmol/L His at 200 V/cm using a 7-cm portion of the capillary. As one can see, the separation occurs in <10 min. Fig. 6Up shows the analysis of all the genotypes we identified in our sample population; superimposition of the tracings demonstrates the reproducibility of the system. To control the system reproducibility, we analyzed 50 samples, previously genotyped by dot-blot hybridization, and we observed excellent assay-to-assay reproducibility; the SD was ±2%. This analysis also confirmed that double-stranded DNA amplified with stepdown PCR did not contain any artificial change of repetitive number as compared with traditional PCR carried out previously on the same samples.

It might sound odd that CZE in standard TBE buffer should not be able to separate, e.g., the 5T-7T or 7T-9T doublets, both having length differences of ~4%, when conventional sequencing gels have a resolution even <1% size difference. It should be noted, however, that (a) standard sequencing gels have a much higher resolution than sieving polymer solutions because of a fixed-pore geometry and (b) the 5T to 9T DNA fragments have a relatively small size (59 to 63 bp) and thus a considerably higher diffusion rate in loose polymer networks. The unique resolving power obtained in our isoelectric His buffer might be due to a combination of the following factors: (a) stiffening of the double helix by potential interactions with His, and (b) reduced transit times due to relatively higher voltages and shorter capillary lengths.

Compared with the previous report on the separation of single-stranded DNA fragments amplified by asymmetric PCR (44), our method is a model of a difficult separation on double-stranded DNA and offers the advantage of much reduced transit times in PCR product analysis, which is one of the important factors to apply CZE technique to automated DNA diagnosis.

Our data show that CZE in liquid polymers in the presence of isoelectric His is the technique of choice to analyze short, double-stranded, PCR-amplified DNA fragments, differing by as little as even the same 2-bp repeated unit.


   Acknowledgments
 
This work was partially funded by Ministero della Sanità, Progetto Fibrosi Cistica, and Bio-Rad Labs. P.G.R. is supported by grants from Telethon-Italy (N. E.555), from the European Community (Biomed II, grant BMH4-CT97-2627), and from Associazione Italiana Ricerca sul Cancro (AIRC-Milano).


   Footnotes
 
1 Nonstandard abbreviations: CFTR, cystic fibrosis conductance transmembrane regulator; CBAVD, congenital bilateral absence of the vas deferens; CF, cystic fibrosis; CZE, capillary zone electrophoresis; TBE, Tris borate EDTA buffer; His, histidine; LIF, laser-induced fluorescence; and dNTP, deoxynucleotide triphosphate.


   References
Top
Abstract
Introduction
Materials and Methods
Results and Discussion
References
 

  1. Jequier AM, Ansell ID, Bullmore NJ. Congenital absence of the vasa deferentia presenting with infertility. J Androl 1985;6:15-19. [Abstract/Free Full Text]
  2. Holsclaw DS, Lobel B, Jockin H, Shwachman H. Genital abnormalities in male patients with cystic fibrosis. J Urol 1971;106:568-574. [ISI][Medline] [Order article via Infotrieve]
  3. Anguiano A, Oates RD, Amos JA, Dean M, Gerrard B, Stewart C, Maher TA, White MB, Milunsky A. Congenital bilateral absence of the vas deferens–a primarily genital form of cystic fibrosis. J Am Med Assoc 1992;267:1794-1797. [Abstract]
  4. Osborne L, Lynch M, Middleton PG, Alton EWFW, Geddes DM, Pryor JP, Hodson ME, Santis GK. Nasal epithelial ion transport and genetic analysis of infertile men with congenital bilateral absence of the vas deferens. Hum Mol Genet 1993;2:1605-1609. [Abstract/Free Full Text]
  5. Patrizio P, Asch R, Handelin B, Silber S. Aetiology of congenital absence of vas deferens: genetic study of three generations. Hum Reprod 1993;8:215-220. [Abstract/Free Full Text]
  6. Culard JF, Desgeorges M, Costa P, Laussel M, Razakatzara G, Navratil H, Demaille J, Claustres M. Analysis of the whole CFTR coding regions and splice junction in azoospermic men with congenital bilateral aplasia of epididymis or vas deferens. Hum Genet 1994;93:467-470. [ISI][Medline] [Order article via Infotrieve]
  7. Chillon M, Casals T, Mercier B, Bassas L, Lissens W, Silber S, Romey MC, Ruiz-Romero J, Verlingue C, Claustres M, Nunes V, Ferec C, Estivill X. Mutations in the cystic fibrosis gene in patients with congenital absence of the vas deferens. N Engl J Med 1995;332:1475-1480. [Abstract/Free Full Text]
  8. Costes B, Girodon E, Ghanem N, Flori E, Jardin A, Soufir JC, Goossens M. Frequent occurrence of the CFTR intron 8 (TG)n 5T allele in men with congenital bilateral absence of the vas deferens. Eur J Hum Genet 1995;3:285-293. [ISI][Medline] [Order article via Infotrieve]
  9. Dumur V, Gervais R, Rigot JM, Lafitte JJ, Manouvrier S, Biserte J, Mazeman M, Roussel P. Abnormal distribution of {Delta}F508 allele in azoospermic men with congenital aplasia of the epididymis and vas deferens. Lancet 1990;336:512.[ISI][Medline] [Order article via Infotrieve]
  10. Bienvenu T, Beldjord C, Adjiman M, Kaplan JC. Male infertility as the only presenting sign of cystic fibrosis when homozygous for the mild mutation R117H. J Med Genet 1993;30:797.
  11. Gervais R, Dumur V, Rigot JM, Lafitte JJ, Roussel P. High frequency of the R117H cystic fibrosis mutation in patients with congenital absence of the vas deferens. N Engl J Med 1993;328:446-447. [Free Full Text]
  12. Kiesewetter S, Macek M, Jr, Davis C, Curristin SM, Chu C-S, Graham C, et al. A mutation in CFTR produces different phenotypes depending on chromosomal background. Nat Genet 1993;5:274-278. [ISI][Medline] [Order article via Infotrieve]
  13. Rave-Harel N, Madgar I, Goshen R, Nissim-Rafinia M, Ziadni A, Rahat A, et al. CFTR haplotype analysis reveals genetic heterogeneity in the etiology of congenital bilateral aplasia of the vas deferens. Am J Hum Genet 1995;56:1359-1366. [ISI][Medline] [Order article via Infotrieve]
  14. Mercier B, Verlingue C, Lissens W, Silber SJ, Novelli G, Bonduelle M, et al. Is congenital bilateral absence of vas deferens a primary form of cystic fibrosis? Analyses of the CFTR gene in 67 patients. Am J Hum Genet 1995;56:272-277. [ISI][Medline] [Order article via Infotrieve]
  15. Chu CS, Trapnell BC, Curristin S, Cutting GR, Crystal RG. Genetic basis of variable exon 9 skipping in cystic fibrosis transmembrane conductance regulator mRNA. Nat Genet 1993;3:151-156. [ISI][Medline] [Order article via Infotrieve]
  16. Rave-Harel N, Kerem E, Nissim-Rafinia M, Madjar I, Goshen R, Augarten A, et al. The molecular basis of partial penetrance of splicing mutations in cystic fibrosis. Am J Hum Genet 1997;60:87-94. [ISI][Medline] [Order article via Infotrieve]
  17. Dork T, Fislage R, Neumann T, Wulf B, Tummler B. Exon 9 of the CFTR gene: splice site haplotypes and cystic fibrosis mutations. Hum Genet 1994;93:67-73. [ISI][Medline] [Order article via Infotrieve]
  18. Gelfi C, Cremonesi L, Ferrari M, Righetti PG. Temperature programmed capillary electrophoresis for detection of DNA point mutations. Biotechniques 1996;21:926-932. [ISI][Medline] [Order article via Infotrieve]
  19. Gelfi C, Righetti PG, Travi M, Fattore S. Temperature programmed capillary electrophoresis for the analysis of high-melting point mutants in thalassemias. Electrophoresis 1997;18:724-731. [ISI][Medline] [Order article via Infotrieve]
  20. Gelfi C, Righetti PG, Magnani C, Cremonesi L, Ferrari M. Simultaneous detection of {Delta}F508, G542X, N1303K and 1717–1G->A mutations in cystic fibrosis by capillary electrophoresis in polymer networks. Clin Chim Acta 1994;229:181-189. [ISI][Medline] [Order article via Infotrieve]
  21. Khrapko K, Hanekamp JS, Thilly WG, Belenki A, Foret F, Kerger BL. Constant denaturant capillary electrophoresis: a high resolution approach to mutational analysis. Nucleic Acids Res 1994;22:364-369. [Abstract/Free Full Text]
  22. Gelfi C, Righetti PG, Brancolini V, Cremonesi L, Ferrari M. Capillary electrophoresis in polymer networks for analysis of PCR products: detection of {Delta}F508 mutation in cystic fibrosis. Clin Chem 1994;40:1603-1605. [Free Full Text]
  23. Gelfi C, Orsi A, Leoncini F, Righetti PG, Spiga I, Carrera P, Ferrari M. Amplification of 18 dystrophin gene exons in DMD/BMD patients: simultaneous resolution by capillary electrophoresis in sieving liquid polymers. Biotechniques 1995;19:254-263. [ISI][Medline] [Order article via Infotrieve]
  24. Fortina P, Cheng J, Shoffner MA, Surrey S, Hitchcock WM, Kricka LJ, Wilding P. Diagnosis of Duchenne/Becker muscular dystrophy and quantitative identification of carrier status by use of entangled solution capillary electrophoresis. Clin Chem 1997;43:745-751. [Abstract/Free Full Text]
  25. Brownlee RG, Sunzeri FJ, Busch MP. Application of CZE to detect AIDS virus (HIV-1) DNA in blood. J Chromatogr 1990;533:87-97. [ISI][Medline] [Order article via Infotrieve]
  26. Schwartz HE, Ulfelder KJ, Sunzeri FJ, Busch MP, Brownlee RG. Analysis of DNA restriction fragments and polymerase chain reaction products toward detection of the AIDS virus in blood. J Chromatogr 1991;559:267-284. [ISI][Medline] [Order article via Infotrieve]
  27. Gelfi C, Orsi A, Righetti PG, Zanussi M, Carrera P, Ferrari M. Capillary zone electrophoresis in polymer networks of polymerase chain reaction-amplified oligonucleotides: the case of congenital adrenal hyperplasia. J Chromatogr B 1994;657:201-205. [ISI][Medline] [Order article via Infotrieve]
  28. Ulfelder KJ, Schwartz HE, Hall JM, Sunzeri FJ. Restriction fragment length polymorphism analysis of ERBB2 oncogene by capillary electrophoresis. Anal Biochem 1992;200:260-267. [ISI][Medline] [Order article via Infotrieve]
  29. McCord BR, Jung JM, Holleran EA. CZE of forensic DNA using a non-gel-sieving buffer. J Liquid Chromatogr 1993;16:1963-1981.
  30. Butler JM, McCord BR, Jung JM, Allen RO. Rapid analysis of the short tandem repeat HUMTH01 by capillary electrophoresis. Biotechniques 1994;17:1062-1070. [ISI][Medline] [Order article via Infotrieve]
  31. Del Principe D, Iampieri MP, Germani D, Menichelli A, Novelli G, Dallapiccola B. Detection by CZE of restriction fragment length polymorphism. Analysis of a PCR-amplified product of the DXS 164 locus in dystrophine gene. J Chromatogr 1993;638:277-282. [ISI][Medline] [Order article via Infotrieve]
  32. Williams PE, Marino MA, del Rio SA, Turni LA, Devaney JM. Analysis of DNA restriction fragments and polymerase chain reaction products by capillary electrophoresis. J Chromatogr A 1994;680:525-540. [ISI][Medline] [Order article via Infotrieve]
  33. Mansfield ES, Veiner M, Enad S, Baker DL, Rappaport E, Fortina P. Sensitivity, reproducibility and accuracy in short tandem repeat genotyping using capillary array electrophoresis. Genome Res 1996;6:893-903. [Abstract/Free Full Text]
  34. Rossomando EF, White L, Ulfelder KJ. Capillary electrophoresis: separation and quantitation of reverse transcriptase polymerase chain reaction products from polio virus. J Chromatogr B 1994;656:159-168. [ISI][Medline] [Order article via Infotrieve]
  35. Butler JM, McCord BR, Jung JM, Wilson MR, Budowle B, Allen RO. Quantitation of polymerase chain reaction products by capillary electrophoresis using laser fluorescence. J Chromatogr B 1994;658:271-280. [ISI][Medline] [Order article via Infotrieve]
  36. Fasco MJ, Treanor CP, Spivack S, Figge HL, Kaminsky LS. Quantitative RNA-polymerase chain reaction products by capillary electrophoresis using laser fluorescence. Anal Biochem 1995;224:140-147. [ISI][Medline] [Order article via Infotrieve]
  37. Gelfi C, Cossu G, Carta M, Serra M, Righetti PG. Gene dosage in capillary electrophoresis: pre-natal diagnosis of Down's syndrome. J Chromatogr A 1995;728:405-412.
  38. Cossu G, Angius T, Gelfi C, Righetti PG. Rapid Rh D/d genotyping by quantitative PCR and capillary zone electrophoresis. Electrophoresis 1996;17:1911-1915. [ISI][Medline] [Order article via Infotrieve]
  39. Cheng J, Kasuga T, Watson ND, Mitchelson KR. Enhanced single strand DNA conformation polymorphism analysis by entangled solution capillary electrophoresis. J Capillary Electrophor 1995;2:24-29.
  40. Gelfi C, Orsi A, Leoncini F, Righetti PG. Fluidized polyacrylamides as molecular sieves in capillary zone electrophoresis of DNA fragments. J Chromatogr A 1995;689:97-105.
  41. Baba Y, Ishimaru N, Samata K, Tsuhako M. High-resolution separation of DNA restriction fragments by capillary electrophoresis in cellulose derivates. J Chromatogr 1993;653:329-335.
  42. Gelfi C, Orsi A, Righetti PG, Brancolini V, Cremonesi L, Ferrari M. Capillary zone electrophoresis of polymerase chain reaction-amplified DNA fragments in polymer networks: the case of GATT microsatellites in cystic fibrosis. Electrophoresis 1994;15:640-643. [ISI][Medline] [Order article via Infotrieve]
  43. Gelfi C, Righetti PG, Leoncini F, Brunelli V, Carrera P, Ferrari M. CAG triplet analysis in families with androgen insensitivity syndrome by capillary electrophoresis in polymer networks. J Chromatogr A 1995;706:463-468. [ISI][Medline] [Order article via Infotrieve]
  44. Oto M, Koguchi A, Yuasa Y. Analysis of a polyadenine tract of the transforming growth factor-ß type II receptor gene in colorectal cancers by non-gel-sieving capillary electrophoresis. Clin Chem 1997;43:759-763. [Abstract/Free Full Text]
  45. Gelfi C, Perego M, Righetti PG. Capillary electrophoresis of oligonucleotides in sieving liquid polymers in isoelectric buffers. Electrophoresis 1996;17:1470-1475. [ISI][Medline] [Order article via Infotrieve]
  46. Stoyanov AV, Gelfi C, Righetti PG. Capillary zone electrophoresis of oligonucleotides in isoelectric buffers and against a stationary pH gradient. Electrophoresis 1997;18:717-723. [ISI][Medline] [Order article via Infotrieve]
  47. Schwartz HE, Ulfelder KJ. CZE, laser-induced fluorescence detection of PCR fragments using thiazole orange. Anal Chem 1992;64:1737-1740.
  48. Arakawa H, Uetanaka K, Maeda M, Tsuji A, Matsubara Y, Narisawa K. Analysis of polymerase chain reaction-products by capillary electrophoresis with laser induced fluorescence detection and its application to the diagnosis of medium-chain acyl-coenzyme A dehydrogenase deficiency. J Chromatogr A 1994;680:517-523. [ISI][Medline] [Order article via Infotrieve]
  49. Wang Y, Ju J, Carpenter BA, Atherton JM, Sensabaugh GF, Mathies RA. Rapid sizing of short tandem repeat alleles using capillary array electrophoresis and energy-transfer fluorescence primers. Anal Chem 1995;67:1197-1203. [Medline] [Order article via Infotrieve]
  50. Zielenski J, Rozmahel R, Bozon D, Kerem B-S, Grzelczak Z, Riordan RR, et al. Genomic DNA sequences of the cystic fibrosis transmembrane conductance regulator (CFTR) gene. Genomics 1991;10:214-228. [ISI][Medline] [Order article via Infotrieve]
  51. Don RH, Wainwright BJ, Baker K, Mattick JS. "Touchdown" PCR to circumvent spurious priming during gene amplification. Nucleic Acids Res 1991;19:4008.[Free Full Text]
  52. Hecker KH, Roux KH. High, low annealing temperatures increase both specificity and yield in touchdown and stepdown PCR. BioTechniques 1996;20:478-485. [ISI][Medline] [Order article via Infotrieve]
  53. Hjertén S, Valtcheva L, Elenbring K, Liao JL. Fast, high resolution capillary electrophoresis in buffers designed for high field strengths. Electrophoresis 1995;16:584-594. [ISI][Medline] [Order article via Infotrieve]



The following articles in journals at HighWire Press have cited this article:


Home page
Hum ReprodHome page
A. Grangeia, F. Niel, F. Carvalho, S. Fernandes, A. Ardalan, E. Girodon, J. Silva, L. Ferras, M. Sousa, and A. Barros
Characterization of cystic fibrosis conductance transmembrane regulator gene mutations and IVS8 poly(T) variants in Portuguese patients with congenital absence of the vas deferens
Hum. Reprod., November 1, 2004; 19(11): 2502 - 2508.
[Abstract] [Full Text] [PDF]


Home page
Clin. Chem.Home page
E. Kamory, B. Csokay, and Z. Hollo
Rapid Detection of Cystic Fibrosis Transmembrane Conductance Regulator Gene IVS8 5T Variant by Real-Time PCR
Clin. Chem., October 1, 2004; 50(10): 1837 - 1839.
[Full Text] [PDF]


This Article
Right arrow Abstract Freely available
Right arrow Full Text (PDF)
Right arrow Submit an electronic Letter to
the Editor about this paper
Right arrow Alert me when this article is cited
Right arrow Alert me when eLetters are posted
Right arrow Alert me if a correction is posted
Right arrow Citation Map
Services
Right arrow Email this article to a friend
Right arrow Similar articles in this journal
Right arrow Similar articles in PubMed
Right arrow Alert me to new issues of the journal
Right arrow Download to citation manager
Right arrow reprints & permissions
Citing Articles
Right arrow Citing Articles via HighWire
Right arrow Citing Articles via ISI Web of Science (16)
Right arrow Citing Articles via Google Scholar
Google Scholar
Right arrow Articles by Gelfi, C.
Right arrow Articles by Cremonesi, L.
Right arrow Search for Related Content
PubMed
Right arrow PubMed Citation
Right arrow Articles by Gelfi, C.
Right arrow Articles by Cremonesi, L.
Related Collections
Right arrow Molecular Diagnostics and Genetics
Right arrow Automation and Analytical Techniques


HOME HELP FEEDBACK SUBSCRIPTIONS ARCHIVE SEARCH TABLE OF CONTENTS