Clinical Chemistry 45: 581, 1999;
This Article
Right arrow Extract Freely available
Right arrow Full Text (PDF)
Right arrow Submit an electronic Letter to
the Editor about this paper
Right arrow Alert me when this article is cited
Right arrow Alert me when eLetters are posted
Right arrow Alert me if a correction is posted
Services
Right arrow Email this article to a friend
Right arrow Similar articles in this journal
Right arrow Similar articles in ISI Web of Science
Right arrow Similar articles in PubMed
Right arrow Alert me to new issues of the journal
Right arrow Download to citation manager
Right arrow reprints & permissions
Citing Articles
Right arrow Citing Articles via HighWire
Right arrow Citing Articles via ISI Web of Science (4)
Right arrow Citing Articles via Google Scholar
Google Scholar
Right arrow Articles by Billen, J.
Right arrow Articles by Blanckaert, N.
Right arrow Search for Related Content
PubMed
Right arrow PubMed Citation
Right arrow Articles by Billen, J.
Right arrow Articles by Blanckaert, N.
Related Collections
Right arrow Nutrition
(Clinical Chemistry. 1999;45:581.)
© 1999 American Association for Clinical Chemistry, Inc.


Letters

Limited Dynamic Range of a New Assay for Serum Folate

Jaak Billena, Zahur Zaman, Georges Claeys and Norbert Blanckaert

Central Clinical Laboratories, Department of Clinical Pathology, University Hospitals Leuven,, B-3000 Leuven, Belgium
a Address correspondence to this author at: Department of Clinical Pathology, UZ-K.U. Leuven Medical Center, B-3000 Leuven, Belgium. Fax 32-16-332896; e-mail jaak.billen{at}uz.kuleuven.ac.be %Editor's Note: A representative of the manufacturer declined the opportunity to reply.


To the Editor:

Recently, several new nonisotopic protein-binding folate assays have become available. We have studied the AxSYM folate assay (Abbott Laboratories, Abbott Park, IL), in which folate is quantified by measurement of unoccupied binding sites on the folate-binding protein (1). The calibrators for the assay cover the range 0–45 nmol/L.

In the absence of an internationally accepted reference method or material (2), we have compared the performance of the AxSYM method with two methods commonly used nationally and internationally, namely the SimulTrac-SNB (ICN Pharmaceuticals Inc.) and the Quantaphase II (Bio-Rad Laboratories). Both of these are competitive RIAs.

We selected 100 patient samples from among serum specimens received in the laboratory for determination of serum folate to obtain a concentration range up to 68 nmol/L (30 µg/L) as measured by the SimulTrac-SNB assay. The sera were frozen at -20 °C until analysis. After thawing, all three comparison assays were performed on the same day. Sample collection procedures were in agreement with the guidelines of the hospital's Ethical Commission.

Results by the two comparison methods agreed well, with Passing–Bablok (3) analysis yielding the following regression equation: y (Quantaphase II) = 0.93x (SimulTrac) - 0.23 nmol/L; r = 0.942; n = 100. In comparisons of the AxSYM assay with the two isotopic methods, the regression plots (Fig. 1 , A and C) and the Bland–Altman (4) bias plots (Fig. 1 , B and D) suggested regression lines with three different slopes. Above 23 nmol/L (10 µg/L) as measured by the comparison methods, the AxSYM method produced a flat response. Linearity of the assays was tested by mixing a very high (45 nmol/L) and a very low sample (1 nmol/L) to obtain increasing concentrations in steps of 10%. Each mixture was tested in duplicate, and statistical evaluations were made by linear regression analysis. The AxSYM method showed significant nonlinearity (Fig. 1E ). The analogous plots for SimulTrac and Quantaphase II were linear between 10% and 100% of high sample, with r2 = 0.996 and r2 = 0.999, respectively. The measured/expected concentration was between 99% and 101% at the highest values.



View larger version (21K):
[in this window]
[in a new window]
 
Figure 1. Comparison of results for 100 serum folate samples.

(A), AxSYM folate assay vs Quantaphase II folate assay (y = 0.63x + 2.8 nmol/L; r = 0.824; n = 100). (B), difference of AxSYM and Quantaphase II folate plotted against the average of AxSYM and Quantaphase II folate; horizontal lines are the mean bias (· · · · ·) and ± 2 SD values (- · - · - · -). (C), AxSYM folate assay vs SimulTrac folate assay (y = 0.58x + 2.7 nmol/L; r = 0.823; n = 100). (D), difference of AxSYM and SimulTrac folate plotted against the average of AxSYM and SimulTrac folate; 1, patients with renal failure. (E), linearity study; (——), least-squares linear regression line for the points at 10–30% high sample.

Although the manufacturer's product insert states that "some samples in the upper region of the dynamic range may read lower in the AxSYM assay when compared with some other commercial assays", our data suggest that samples >23 nmol/L (the middle of the dynamic range) routinely read lower in the AxSYM assay than in either of the two widely used methods. In agreement with the manufacturer's warning that "serum and plasma specimens from patients with renal impairment may exhibit varying degrees of falsely depressed values", marked disagreement was observed between the AxSYM and the comparison methods for the serum specimens of chronic renal failure patients (indicated by the numeral 1 in Fig. 1Up ).

Similar apparent limitations in the dynamic range of the AxSYM method appeared to be present when folate was measured in erythrocyte hemolysates. At concentrations >906 nmol/L (>400 µg/L) with the SimulTrac method and >453 nmol/L (>200 µg/L) with the Quantaphase II method, the regression lines were found to bend. We saw no erythrocyte folate results >1360 nmol/L (>600 µg/L) by the AxSYM method, even in patients known to be taking folate supplements regularly for a protracted period of time.

We conclude that the dynamic range of the AxSYM folate assay does not extend above 23 nmol/L (10 µg/L) for serum folate and not above 1360 nmol/L (600 µg/L) for erythrocyte folate. This is only half the dynamic range of other protein-binding folate assays.


References

  1. Wilson DH, Herrmann R, Hsu S, Biegalski T, Sohn L, Forsythe C, et al. Ion capture assay for folate with the Abbott IMx analyzer. Clin Chem 1995;41:1780-1781.[ISI][Medline] [Order article via Infotrieve]
  2. Gunter EW, Cowman BA, Caudal SP, Twit dB, Adams MJ, Sampson EJ. Results of an international round robin for serum and whole-blood folate. Clin Chem 1996;42:1689-1694.[Abstract/Free Full Text]
  3. Passing H, Bablok W. A new biometrical procedure for testing the equality of measurements from two different analytical methods. Application of linear regression procedures for method comparison studies in clinical chemistry. Part I. J Clin Chem Clin Biochem 1983;21:709-720.[ISI][Medline] [Order article via Infotrieve]
  4. Bland JM, Altman DG. Statistical methods for assessing agreement between two methods of clinical measurement. Lancet 1986;i:307-310.



The following articles in journals at HighWire Press have cited this article:


Home page
Clin. Chem.Home page
D. H. Wilson, G. Williams, R. Herrmann, D. Wiesner, and P. Brookhart
Issues in Immunoassay Standardization: The ARCHITECT Folate Model for Intermethod Harmonization
Clin. Chem., April 1, 2005; 51(4): 684 - 687.
[Full Text] [PDF]


This Article
Right arrow Extract Freely available
Right arrow Full Text (PDF)
Right arrow Submit an electronic Letter to
the Editor about this paper
Right arrow Alert me when this article is cited
Right arrow Alert me when eLetters are posted
Right arrow Alert me if a correction is posted
Services
Right arrow Email this article to a friend
Right arrow Similar articles in this journal
Right arrow Similar articles in ISI Web of Science
Right arrow Similar articles in PubMed
Right arrow Alert me to new issues of the journal
Right arrow Download to citation manager
Right arrow reprints & permissions
Citing Articles
Right arrow Citing Articles via HighWire
Right arrow Citing Articles via ISI Web of Science (4)
Right arrow Citing Articles via Google Scholar
Google Scholar
Right arrow Articles by Billen, J.
Right arrow Articles by Blanckaert, N.
Right arrow Search for Related Content
PubMed
Right arrow PubMed Citation
Right arrow Articles by Billen, J.
Right arrow Articles by Blanckaert, N.
Related Collections
Right arrow Nutrition


HOME HELP FEEDBACK SUBSCRIPTIONS ARCHIVE SEARCH TABLE OF CONTENTS