Clinical Chemistry AACC Online Job Center
HOME HELP FEEDBACK SUBSCRIPTIONS ARCHIVE SEARCH TABLE OF CONTENTS
 QUICK SEARCH:   [advanced]


     


Clinical Chemistry 46: 1037-1038, 2000;
This Article
Right arrow Extract Freely available
Right arrow Full Text (PDF)
Right arrow Submit an electronic Letter to
the Editor about this paper
Right arrow Alert me when this article is cited
Right arrow Alert me when eLetters are posted
Right arrow Alert me if a correction is posted
Right arrow Citation Map
Services
Right arrow Email this article to a friend
Right arrow Similar articles in this journal
Right arrow Similar articles in ISI Web of Science
Right arrow Similar articles in PubMed
Right arrow Alert me to new issues of the journal
Right arrow Download to citation manager
Right arrow reprints & permissions
Citing Articles
Right arrow Citing Articles via HighWire
Right arrow Citing Articles via ISI Web of Science (40)
Right arrow Citing Articles via Google Scholar
Google Scholar
Right arrow Articles by Kricka, L. J.
Right arrow Search for Related Content
PubMed
Right arrow PubMed Citation
Right arrow Articles by Kricka, L. J.
Related Collections
Right arrow Laboratory Management
Right arrow Automation and Analytical Techniques
(Clinical Chemistry. 2000;46:1037-1038.)
© 2000 American Association for Clinical Chemistry, Inc.


Editorials

Interferences in Immunoassay—Still a Threat

Larry J. Kricka

Department of Pathology and Laboratory Medicine, 7.103 Founders Pavilion, University of Pennsylvania Medical Center, 3400 Spruce St., Philadelphia, PA 19104, E-mail kricka{at}mail.med.upenn.edu

Few things in life are perfect, and unfortunately this also applies to medical diagnostic procedures such as clinical laboratory testing. In spite of the careful efforts of the developers and manufacturers of clinical laboratory tests and the vigilance of the laboratory staffs that perform the testing, most if not all tests are, on occasion, subject to interferences that lead to false-positive or false-negative results (1)(2). Immunoassay tests are no exception. Recent literature has documented false-positive or false-negative results in immunoassays or reports investigations of specific interferences (3)(4). Sources of interferences include plasma (5), serum proteins (e.g., rheumatoid factor, binding proteins) (6)(7), heterophile and anti-animal antibodies (2)(8)(9), drugs and drug metabolites (10)(11), hemolysis (12), agar (13), and cross-reacting substances (14).

In most cases, a significant interference is recognized and flagged, but sometimes the interference is unsuspected and undetected. There now is adequate evidence that bad things can happen when false-positive immunoassay test results go unrecognized. The consequences are that the result is seen as a true positive, signifying underlying disease, and that further diagnostic or therapeutic procedures are initiated.

Recent publications have drawn attention to the consequences of false-positive human chorionic gonadotropin (hCG) test results (15)(16). In the series of patients described by Cole et al. (15) and Rotmensch and Cole (16), the false-positive hCG results led to unnecessary surgery and inappropriate chemotherapy. This was because the patients concerned were thought to have postgestational choriocarcinoma or trophoblast disease based on their persistently increased hCG results. In addition, one of the patients developed type I diabetes and lapsed into a coma as a complication of the chemotherapy. Others have documented unnecessary surgical procedures or follow-up testing because of false-positive hCG, follicle-stimulating hormone, or thyroid-stimulating hormone results attributable to circulating antibodies with anti-rabbit specificity (17)(18).

A report in this issue of Clinical Chemistry describes some clever laboratory sleuthing that has uncovered yet another cause of false-positive test results in immunoassays—broadly reactive antibodies induced by infection with a gram-negative microorganism (19). A patient with an Escherichia coli septicemia was found to have increased immunoassay results for cardiac troponin I, thyroid-stimulating hormone, hCG, {alpha}-fetoprotein, and CA-125, but none of these results was consistent with the clinical findings. Serum protein electrophoresis revealed that the patient also had a restricted IgM {lambda} peak. This was identified as the cause of the falsely increased values in the immunometric assays. The circulating restricted antibody presumably recognized the capture and detection antibodies used in the immunoassays because it could be adsorbed with an irrelevant mouse antibody. It thus formed complexes that were indistinguishable from the complexes formed when the specific antigens bound their respective immobilized capture antibody and detection antibody. This observation may provide a new avenue of inquiry that could lead to novel strategies to block immunoassay interferences. Previously, increased concentrations of antibodies (M-spikes, paraproteins) in serum have been recognized as a source of analytical interference because of precipitation, viscosity, or binding effects (20), and the interference described in this report (19) extends the range of this particular type of interference.

Public awareness of the scope and extent of medical errors has been heightened by the recent Institute of Medicine report To err is human (21). Medical errors originating from a false-positive immunoassay result have not received the same notoriety as therapeutic or surgical errors; nevertheless, they continue to be a source of concern, and if unrecognized they can have serious adverse consequences for patients.

How can we guard against the false-positive or -negative immunoassay results in the future? Dialogue between the physician and the clinical laboratory over unexpected immunoassay test results is one route to avoiding inappropriate clinical intervention based on an abnormal test result. The laboratory can help in several ways. It can provide up-to-date information on assay performance, and review and discuss with the physician the test limitations as outlined in the test package insert. Further testing can be arranged to confirm the test result (i.e., repeat analysis on the specimen, retest a second specimen, or arrange for analysis by another method). In addition, dilution or blocking studies can be performed to confirm the suspicion of the presence of an interferent. Patient education programs could make patients more knowledgeable about the limitations and pitfalls of immunoassay tests and encourage patients to tell their physicians about possible sources of interferences (e.g., likelihood of having anti-animal antibodies attributable to handling of animals or prior exposure to anti-animal diagnostic or therapeutic agents). Finally, for the manufacturers of immunoassay test kits, there must be agreed guidelines for characterizing the effects of interfering substances (22), continued surveillance for new interfering factors, and refinement of immunoassays to render them interference free.


References

  1. Selby C. Interference in immunoassay. Ann Clin Biochem 1999;36:704-721.
  2. Kricka LJ. Human anti-animal antibody interference in immunological assays. Clin Chem 1999;45:942-956. [Abstract/Free Full Text]
  3. Preiser W, Brink NS, Hayman A, Waite J, Balfe P, Tedder RS. False-negative HIV antibody test results. J Med Virol 2000;600:43-47.
  4. Zehender G, De Maddalena C, Gianotto M, Cavalli B, Santambrogio S, Orso M, et al. High prevalence of false-negative anti-HTLV type I/II enzyme-linked immunosorbent assay results in HIV type 1-positive patients. AIDS Res Hum Retroviruses 1997;3:1141-1146.
  5. Nemzek JA, Newcomb DE, Call DR, Remick DG. Plasma interference in an enzyme-linked immunosorbant assay using a commercial matched antibody pair. Immunol Investig 1999;28:209-221. [ISI][Medline] [Order article via Infotrieve]
  6. Krahn J, Parry DM, Leroux M, Dalton J. High percentage of false positive cardiac troponin I results in patients with rheumatoid factor. Clin Biochem 1999;32:477-480. [ISI][Medline] [Order article via Infotrieve]
  7. Ebdrup L, Fisker S, Sorensen HH, Ranke MB, Orskov H. Variety in growth hormone determinations due to use of different immunoassays and to the interference of growth hormone-binding protein. Horm Res 1999;51(Suppl 1):20-26.
  8. Hennig C, Rink L, Fagin U, Jabs WJ, Kirchner H. The influence of naturally occurring heterophilic anti-immunoglobulin antibodies on direct measurement of serum proteins using sandwich ELISAs. J Immunol Methods 2000;235:71-80. [ISI][Medline] [Order article via Infotrieve]
  9. Revelen R, Bordron A, Dueymes M, Youinou P, Arvieux J. False positivity in a cyto-ELISA for anti-endothelial cell antibodies caused by heterophile antibodies to bovine serum proteins. Clin Chem 2000;46:273-278. [Abstract/Free Full Text]
  10. Lichtenwalner MR, Mencken T, Tully R, Petosa M. False-positive immunochemical screen for methadone attributable to metabolites of verapamil. Clin Chem 1998;44:1039-1041. [Free Full Text]
  11. Dasgupta A, Wells A, Datta P. Effect of digoxin Fab antibody on the measurement of total and free digitoxin by fluorescence polarization and a new chemiluminescent immunoassay. Ther Drug Monit 1999;21:251-255. [ISI][Medline] [Order article via Infotrieve]
  12. Wenk RE. Mechanism of interference by hemolysis in immunoassays and requirements for sample quality. Clin Chem 1998;44:2554.[Free Full Text]
  13. Sales V, Miller MA, Libman M. False-positive enzyme immunoassay test results for Chlamydia trachomatis because of contact of the collection swab with agar. Sex Transm Dis 1998;25:418-420. [ISI][Medline] [Order article via Infotrieve]
  14. Miller JJ, Valdes R, Jr. Approaches to minimizing interference by cross-reacting molecules in immunoassays. Clin Chem 1991;37:144-153. [Abstract/Free Full Text]
  15. Cole LA, Rinne KM, Shahabi S, Omrani A. False-positive hCG assay results leading to unnecessary surgery and chemotherapy and needless occurrences of diabetes and coma. Clin Chem 1999;45:313-314. [Free Full Text]
  16. Rotmensch S, Cole LA. False diagnosis and needless therapy of presumed malignant disease in women with false-positive human chorionic gonadotropin concentrations. Lancet 2000;355:712-715. [ISI][Medline] [Order article via Infotrieve]
  17. Berglund L, Holmberg N-G. Heterophilic antibodies against rabbit serum causes falsely elevated gonadotropin levels. Acta Obstet Gynecol Scand 1989;68:377-378. [ISI][Medline] [Order article via Infotrieve]
  18. Schaison G, Thomopoulos P, Moulias R, Feinstein MC. False hyperthyrotropinemia induced by heterophilic antibodies against rabbit serum. J Clin Endocrinol Metab 1981;53:200-202. [Abstract]
  19. Covinsky M, Laterza O, Pfeifer JD, Farkas-Szallasi T, Scott MG. IgM {lambda} antibody to Escherichia coli produces false-positive results in multiple immunometric assays. Clin Chem 2000;46:1157-1161. [Abstract/Free Full Text]
  20. Granouillet R, Rascle F, Chamson A, Frey J, Perier C. Monoclonal IgM interference during measurement of reactive protein C and ferritin by immunonephelometry. Ann Biol Clin 1998;56:485-486.
  21. Kohn LT, Corrigan JM, Donaldson MS, eds. To err is human: building a safer health system. Committee on Quality of Health Care in America, Institute of Medicine. Washington: National Academy Press, 2000:312 pp..
  22. Powers DM. Interference testing in clinical chemistry; proposed guideline. NCCLS Document EP7-P, Wayne, PA: NCCLS, 1986..



The following articles in journals at HighWire Press have cited this article:


Home page
Clin. Chem.Home page
L. J. Kricka
Commentary
Clin. Chem., July 1, 2008; 54(7): 1245 - 1245.
[Full Text] [PDF]


Home page
Clin. Chem.Home page
NACB WRITING GROUP MEMBERS, A. H.B. Wu, A. S. Jaffe, F. S. Apple, R. L. Jesse, G. L. Francis, D. A. Morrow, L. K. Newby, J. Ravkilde, W.H. W. Tang, et al.
National Academy of Clinical Biochemistry Laboratory Medicine Practice Guidelines: Use of Cardiac Troponin and B-Type Natriuretic Peptide or N-Terminal proB-Type Natriuretic Peptide for Etiologies Other than Acute Coronary Syndromes and Heart Failure
Clin. Chem., December 1, 2007; 53(12): 2086 - 2096.
[Abstract] [Full Text] [PDF]


Home page
CVIHome page
L. J. Wheat, M. D. Lindsley, H. L. Holland, S. L. Bragg, S. F. Hurst, K. A. Wannemuehler, and C. J. Morrison
Evaluation of Reagents for Detection of Histoplasma capsulatum Antigenuria
Clin. Vaccine Immunol., October 1, 2007; 14(10): 1387 - 1388.
[Full Text] [PDF]


Home page
Clin. Chem.Home page
P. Carraro and M. Plebani
Errors in a Stat Laboratory: Types and Frequencies 10 Years Later
Clin. Chem., July 1, 2007; 53(7): 1338 - 1342.
[Abstract] [Full Text] [PDF]


Home page
J. Clin. Microbiol.Home page
K. Becker, A. S. Almasri, C. von Eiff, G. Peters, C. Heilmann, and W. Fegeler
Systematic Survey of Nonspecific Agglutination by Candida spp. in Latex Assays
J. Clin. Microbiol., April 1, 2007; 45(4): 1315 - 1318.
[Abstract] [Full Text] [PDF]


Home page
Clin. Chem.Home page
J. D. Newman, P. B. Bergman, J. C.G. Doery, and N. D.H. Balazs
Factitious increase in thyrotropin in a neonate caused by a maternally transmitted interfering substance.
Clin. Chem., March 1, 2006; 52(3): 541 - 542.
[Full Text] [PDF]


Home page
Clin. Chem.Home page
A. A.A. Ismail
A Radical Approach Is Needed to Eliminate Interference from Endogenous Antibodies in Immunoassays
Clin. Chem., January 1, 2005; 51(1): 25 - 26.
[Full Text] [PDF]


Home page
Clin. Chem.Home page
P. A. Torjesen, L. Sandnes, and P. Boudou
Serum Testosterone in Women as Measured by an Automated Immunoassay and a RIA * Dr. Boudou responds for the authors of the article cited above:
Clin. Chem., March 1, 2004; 50(3): 678 - 679.
[Full Text] [PDF]


Home page
Clin. Chem.Home page
J. F. Emerson, G. Ngo, and S. S. Emerson
Screening for Interference in Immunoassays
Clin. Chem., July 1, 2003; 49(7): 1163 - 1169.
[Abstract] [Full Text] [PDF]


Home page
Clin. Chem.Home page
A. A.A. Ismail, P. L. Walker, J. H. Barth, K. C. Lewandowski, R. Jones, and W. A. Burr
Wrong Biochemistry Results: Two Case Reports and Observational Study in 5310 Patients on Potentially Misleading Thyroid-stimulating Hormone and Gonadotropin Immunoassay Results
Clin. Chem., November 1, 2002; 48(11): 2023 - 2029.
[Abstract] [Full Text] [PDF]


Home page
Clin. Chem.Home page
J. Bjerner, K. Nustad, L. F. Norum, K. H. Olsen, and O. P. Bormer
Immunometric Assay Interference: Incidence and Prevention
Clin. Chem., April 1, 2002; 48(4): 613 - 621.
[Abstract] [Full Text] [PDF]


Home page
BMJHome page
A. A. Ismail and J. H Barth
Wrong biochemistry results
BMJ, September 29, 2001; 323(7315): 705 - 706.
[Full Text] [PDF]


Home page
Clin. Chem.Home page
M. N. Fahie-Wilson and R. John
Detection of Macroprolactin Causing Hyperprolactinemia in Commercial Assays for Prolactin Dr. John responds:
Clin. Chem., December 1, 2000; 46(12): 2022 - 2023.
[Full Text] [PDF]


This Article
Right arrow Extract Freely available
Right arrow Full Text (PDF)
Right arrow Submit an electronic Letter to
the Editor about this paper
Right arrow Alert me when this article is cited
Right arrow Alert me when eLetters are posted
Right arrow Alert me if a correction is posted
Right arrow Citation Map
Services
Right arrow Email this article to a friend
Right arrow Similar articles in this journal
Right arrow Similar articles in ISI Web of Science
Right arrow Similar articles in PubMed
Right arrow Alert me to new issues of the journal
Right arrow Download to citation manager
Right arrow reprints & permissions
Citing Articles
Right arrow Citing Articles via HighWire
Right arrow Citing Articles via ISI Web of Science (40)
Right arrow Citing Articles via Google Scholar
Google Scholar
Right arrow Articles by Kricka, L. J.
Right arrow Search for Related Content
PubMed
Right arrow PubMed Citation
Right arrow Articles by Kricka, L. J.
Related Collections
Right arrow Laboratory Management
Right arrow Automation and Analytical Techniques


HOME HELP FEEDBACK SUBSCRIPTIONS ARCHIVE SEARCH TABLE OF CONTENTS