Clinical Chemistry AACC Online Job Center
HOME HELP FEEDBACK SUBSCRIPTIONS ARCHIVE SEARCH TABLE OF CONTENTS
 QUICK SEARCH:   [advanced]


     


Clinical Chemistry 48: 364-366, 2002;
This Article
Right arrow Extract Freely available
Right arrow Full Text (PDF)
Right arrow A correction has been published
Right arrow Submit an electronic Letter to
the Editor about this paper
Right arrow Alert me when this article is cited
Right arrow Alert me when eLetters are posted
Right arrow Alert me if a correction is posted
Right arrow Citation Map
Services
Right arrow Email this article to a friend
Right arrow Similar articles in this journal
Right arrow Similar articles in ISI Web of Science
Right arrow Similar articles in PubMed
Right arrow Alert me to new issues of the journal
Right arrow Download to citation manager
Right arrow reprints & permissions
Citing Articles
Right arrow Citing Articles via HighWire
Right arrow Citing Articles via ISI Web of Science (10)
Right arrow Citing Articles via Google Scholar
Google Scholar
Right arrow Articles by Wu, H.
Right arrow Articles by Aboleneen, H.
Right arrow Search for Related Content
PubMed
Right arrow PubMed Citation
Right arrow Articles by Wu, H.
Right arrow Articles by Aboleneen, H.
Related Collections
Right arrow Endocrinology and Metabolism
(Clinical Chemistry. 2002;48:364-366.)
© 2002 American Association for Clinical Chemistry, Inc.


Technical Briefs

Serum Estradiol Quantified by Isotope Dilution–Gas Chromatography/Mass Spectrometry

Huaiqin Wu1, Carol Ramsay1, Panfilo Ozaeta1, Lin Liu1 and Hoda Aboleneen1a

1 Abbott Laboratories, Diagnostics Division, 100 Abbott Park Rd., Abbott Park, IL 60064

aaddress correspondence to this author at: Abbott Laboratories, Department 90T, Bldg. AP20, 100 Abbott Park Rd., Abbott Park, IL 60064-3500; fax 847-938-7550, e-mail Hoda.aboleneen{at}abbott.com

Estradiol measurements are important in evaluations of ovarian function, infertility, and menopause (1). The assays are challenging because physiologic concentrations of estradiol are typically <100 ng/L in plasma of adult men and postmenopausal women and in both sexes during infancy and childhood (1). Immunoassays are widely used, and they provide high sensitivity and short analysis times (2). Other methods are needed to determine the accuracy of immunoassays. Our aim was to develop a practical gas chromatography–mass spectrometry (GC/MS) method to quantify serum estradiol and use it to evaluate immunoassay accuracy.

Isotope dilution–GC/MS is widely regarded as the most accurate technique for organic analytes of interest in clinical chemistry (3). Several GC/MS methods have been reported for the quantification of estradiol in biological sources (4)(5)(6)(7)(8)(9)(10)(11)(12)(13)(14). The complexity of samples requires isolation and purification of estradiol before derivatization for GC/MS analysis.

The most common separation methods for estradiol involve solvent extraction followed by further purification with Sephadex LH-20 (4)(5), strong ionic exchangers (6)(7)(8)(9), weak ionic exchanger (9)(10)(11), HPLC (12)(13), affinity chromatography (14), or their combinations. These methods, however, have limitations. The HPLC method for estradiol isolation cannot handle multiple samples simultaneously. The affinity column (14) is not commercially available and is very expensive to make. Other methods generally cannot sufficiently remove serum matrix materials to ensure rugged performance.

Here we report a GC/MS method for the quantification of serum estradiol in which estradiol is separated from the ether extract of serum samples by fractionation with a polystyrene divinylbenzene resin that has strong anion- exchange and adsorption properties. The method eliminates the use of HPLC in sample preparation and makes it suitable for routine analysis.

Samples were prepared by liquid–liquid extraction and solid-phase extraction followed by derivatization. Briefly, 1 mL of 1.0 mol/L acetate buffer (pH 5.0) and 100 µL of 10 µg/L estradiol-d3 were added to 2 mL of serum (sample, calibrator, or control) in a 15-mL polypropylene screw-cap centrifuge tube (Corning). The mixture was vortex-mixed for 30 s, equilibrated for 15 min, and saturated with ~20 mg of NaCl; 11 mL of ethyl ether was then added. The tube was then capped, and the estradiol and estradiol-d3 were extracted from the mixture by rocking the tube for 15 min on an aliquot mixer. After centrifugation at 1470g for 7 min, the ether layer was transferred to a 15-mL glass centrifuge tube. The solvent was evaporated under a gentle stream of nitrogen in a 50 °C water bath.

The ether extraction residue was reconstituted in 1.0 mL of 2-propanol–methanol (1:1 by volume) and 2.5 mL of 2.0 mol/L NaOH. After brief vortex-mixing, the solution was applied to a solid-phase XTRX type AXS extraction column (Creative Technology Systems, Inc.) and pulled through by reduced pressure (5–15 mmHg). The column was then washed with 4.0 mL of methanol, 1.5 mL of H2O, 3.0 mL of 50 mL/L acetic acid, and 2.0 mL of methanol–H2O (20:80 by volume). Each wash solution was pulled through the column by reduced pressure (5–15 mmHg). Estradiol and estradiol-d3 were eluted with 4.0 mL of methanol into a 13 x 100 mm culture tube. The methanol was evaporated under a gentle stream of nitrogen in a 60 °C water bath.

We added 100 µL of anhydrous acetonitrile and 30 µL of heptafluorobutyric anhydride to the final residue from the solid-phase extraction. After brief vortex-mixing, the tubes were capped and kept on a heating block at 65 °C for 45 min. We then added 1.0 mL of 1.0 mol/L phosphate buffer (pH 6.0) and 2.0 mL of hexane to the cooled reaction mixture. The tubes were vortex-mixed and centrifuged at 1470g for 4 min. The upper layer was transferred to a 12 x 75 mm culture tube and dried under a gentle stream of nitrogen in a 60 °C water bath. The residue was reconstituted in 20 µL of isooctane. We injected 2 µL of the reconstituted solution into a gas chromatograph (Model 5890 Series II; Hewlett Packard) equipped with an MSD 5970B mass spectrometer (Hewlett Packard). Data acquisition and processing were carried out with the Hewlett Packard UX ChemStation Data System.

GC separation was performed on a J&W DB-1 column (15 m x 0.25 mm i.d.; 0.25-µm film thickness) in splitless mode with helium as the carrier gas. The injection port temperature was 240 °C. The transfer line and detector were at 260 °C. The oven temperature was ramped linearly from 80 to 240 °C at 15 °C/min and held at 240 °C for 5 min. The mass spectrometer was tuned with perfluorotributylamine and used in selected-ion monitoring mode. The two target ions were m/z 664.4 for estradiol and m/z 667.4 for estradiol-d3. The dwell time was 80 ms for both m/z 664.4 and 667.4, which corresponds to 20 cycles (data points) under each peak. The peak-area ratio of m/z 664.4 to m/z 667.4 was obtained for each calibrator, sample, and control.

For the removal of neutral, acidic, and basic compounds in the ethyl ether extract of serum, ion-exchange chromatography has been widely used (4)(5)(6)(7)(8)(9)(10)(11). We used a polystyrene divinylbenzene copolymer resin linked to a quaternary amine anion-exchange moiety to remove, from ether extract, nonacidic species and those showing weak adsorption to polystyrene. The AXS resin used in the procedure offers both anionic and adsorption properties, which have been used for selective extraction of synthetic growth promotants from animal tissues (15)(16). Estradiol in the phenolate anion form was first exchanged to the resin at pH 11. Organic bases and neutral lipid and steroids were then removed during the methanol and H2O washes. The washes with 50 mL/L acetic acid were used to displace the estradiol from the charged portion of the resin; estradiol was then adsorbed to the polystyrene matrix in a reversed-phase fashion. This step allowed the elution of a large quantity of interfering anionic substances previously bound to the resin. The subsequent wash with methanol–H2O (20:80 by volume) removed acetic acid and additional matrix materials. Finally, estradiol was released from the resin by elution with 4 mL of methanol. Under these experimental conditions, estradiol and estradiol-d3 had virtually identical retention times (~11.6 min), and they were monitored on two channels at m/z 664.4 and m/z 667.4, respectively.

Two calibration curves were constructed by plotting the peak-area ratio of estradiol to the internal standard (E2/E2-d3) against the estradiol concentration, [E2]. For the low curve, estradiol was added at 50–1000 ng/L (50, 100, 200, 500, 800, and 1000 ng/L); for the high curve, it was added at 400–3000 ng/L (400, 500, 1000, 2000, and 3000 ng/L). Linear regression analyses of the two curves were then performed. For the high curve, the equation was: E2/E2-d3 = 0.00211[E2] + 0.00784 (r2 = 0.999). The SDs of the slope and y-intercept (n = 6) were 0.00008 and 0.02, respectively. For the low curve, the equation for the line was: E2/E2-d3 = 0.00207[E2] + 0.00386 (r2 = 0.999). The SDs of the slope and y-intercept (n = 6) were 0.00005 and 0.01, respectively. The use of two calibration curves produced a better fit to points at the low end of the concentration range than could be achieved by the use of a weighting factor (1/x, where x equals the estradiol concentration) for linear regression analysis of a single curve. The limit of detection was 15 ng/L [signal-to-noise (S/N) ratio = 3]. The limit of quantification was 30 ng/L (S/N ratio = 10). S/N ratios for the calibrators at 50, 100, 200, 400 ng/L were 65, 100, 240, and 390, respectively. The use of silanized glassware did not improve the detection limit.

Accuracy and precision of the method were assessed by preparing two independent sets of estradiol calibrators and controls in charcoal-stripped normal human serum. For the determination of accuracy, all estradiol concentrations in the two sets were analyzed in triplicate by two different analysts on different days (n = 6). The calibration curve was constructed with the data obtained from one set and was used to determine the concentrations of the second set. The mean deviation from the target concentrations was <7.1%, and the CV was <6.1% across the entire range. The three controls (75, 200, and 800 ng/L) of the second set were analyzed in triplicate by three different analysts on different days (n = 9). The CV was <6.1% for all concentrations in both low and high curves. The overall extraction recovery of estradiol from serum was 52.7%. For a 100 ng/L sample, 10.5 pg of estradiol was actually injected onto the column, and the corresponding S/N ratio was ~100.

The specificity, accuracy, and precision of the method were examined by analyzing Certified Reference Materials (CRMs): CRMs 576, 577, and 578 from the Community Bureau of Reference of the European Commission. Six replicates of each CRM were analyzed (Table 1 ). The measured values were within 4.2% of stated values, and CVs were <=5.2%. The S/N ratios for the three CRMs were 16, 140, and 480, respectively.


View this table:
[in this window]
[in a new window]
 
Table 1. Analysis of estradiol immunoassay calibrators (Abbott) and CRMs by the GC/MS method.

For six Abbott calibrators, GC/MS ratios were within 3% of the target concentrations (Table 1Up ). In a correlation study, estradiol concentrations of 61 patient samples were measured by microparticle enzyme immunoassay [(MEIA); Abbott Architect Estradiol assay) and by GC/MS (Fig. 1 ). The GC/MS and MEIA results were generated by two independent laboratories within Abbott and were submitted to an independent group for statistical analysis. A linear regression was obtained with the following equation: MEIA = 1.09 GC/MS + 44; r2 =0.997. The 95% confidence intervals of the slope and intercept were (1.07–1.11) and (10–65), respectively. The SD of residuals (Sy|x) was 73 ng/L in the concentration range of 0–5000 ng/L and 22 ng/L in the range of 0–500 ng/L. The agreement between the GC/MS and MEIA assays indicated low interference from other estrogenic compounds and their metabolites in the latter assay.



View larger version (17K):
[in this window]
[in a new window]
 
Figure 1. Correlation of estradiol concentrations for 61 patients measured by GC/MS vs MEIA.

The GC/MS data were obtained on a Hewlett Packard 6980 gas chromatograph with an HP5973MSD mass spectrometer.

In conclusion, we have developed a GC/MS method for the quantification of estradiol in patient serum samples and serum-based immunoassay calibrators; the method was validated by use of CRMs. The utility of the method was further demonstrated by the presented correlation between estradiol concentrations in patient samples measured by MEIA and GC/MS.


Acknowledgments

We thank Dr. Greg Williams and his team at Abbott Laboratories for providing the immunoassay data for the patient samples.


References

  1. Burtis CA Ashwood ER eds. Textbook of clinical chemistry, 2nd ed 1994:2175-2217 WB Saunders Philadephia. .
  2. Ratcliffe WA, Carter GD, Dowsett M, Hillier SG, Middle JG, Reed MJ. Oestradiol assays: applications and guidelines for the provision of a clinical biochemistry service. Ann Clin Biochem 1988;25:466-483.
  3. De Leenheer AP, Lefevere MF, Lambert WE, Colinet ES. Isotope-dilution mass spectrometry in clinical chemistry. Adv Clin Chem 1985;24:111-161.[ISI][Medline] [Order article via Infotrieve]
  4. Zamecnik J, Armstrong DT, Green D. Serum estradiol-17b as determined by mass fragmentography and by RIA. Clin Chem 1978;24:627-630.[Abstract/Free Full Text]
  5. Siekmann L. Determination of oestradiol-17b in human serum by isotope dilution-mass spectrometry. J Clin Chem Clin Biochem 1984;22:551-557.[ISI][Medline] [Order article via Infotrieve]
  6. Axelson M, Sjovall J. Analysis of unconjugated steroids in plasma by liquid-gel chromatography and glass capillary gas chromatography-mass spectrometry. J Steroid Biochem 1977;8:683-692.[ISI][Medline] [Order article via Infotrieve]
  7. Axelson M, Clark JH, Eriksson HA, Sjovall J. Estragen binding in target tissues: a GC/MS method for assessing uptake, retention, and processing of estrogens in target cell nuclei under in vivo conditions. J Steroid Biochem 1981;14:1253-1260.[ISI][Medline] [Order article via Infotrieve]
  8. Tetsuo M, Eriksson H, Sjovall J. Gas chromatographic-mass spectrometric analysis of endogenoud levels of estradiol in plasma and in cytosol from rat uterus. J Chromatogr 1982;239:287-300.[ISI][Medline] [Order article via Infotrieve]
  9. Fotsis F, Jarvenpaa P, Adlercreutz H. Purification of urine for quantitation of the complete estrogen profile. J Steroid Biochem 1980;12:503-508.[ISI][Medline] [Order article via Infotrieve]
  10. Sjovall J, Axelson M. General and selective isolation procedures for GC/MS analysis of steroids in tissue and body fluids. J Steroid Biochem 1979;11:129-134.[ISI][Medline] [Order article via Infotrieve]
  11. Heikkinen R, Rotsis T, Adlercreutz H. Use of ion exchange chromatography in steroid analysis. J Steroid Chem 1983;19:175-180.
  12. Thienpont LM, Verhaeghe PG, Van Brussel KA, De Leenheer AP. Estradiol-17ß quantified in serum by ID-GC/MS: RP-C18-HPLC compared with immuno-affinity chromatography for sample pretreatment. Clin Chem 1988;34:2066-2069.[Abstract/Free Full Text]
  13. Thienpont LM, De Leenheer AP. Efforts by industry toward standardization of serum estradiol-17ß measurements. Clin Chem 1998;44:671-674.[Free Full Text]
  14. Gaskell SJ, Brownsey BG. Immunoadsorption to improve gas chromatography/high-resolution mass spectrometry of estradiol-17ß in plasma. Clin Chem 1983;29:677-680.[Abstract/Free Full Text]
  15. Covey TR, Dilvestre D, Hoffman MK, Henion JD. A Gas chromatographic/mass spectrometric screening, confirmation, and quantitation method for estragenic compounds. Biomed Environ Mass Spectrom 1988;15:45-58.[Medline] [Order article via Infotrieve]
  16. Covey T, Maylin G, Henion J. Quantitative secondary ion monitoring gas chromatography/mass spectrometry of diethylstilbestrol in bovine liver. Biomed Mass Spectrom 1985;12:274-287.[ISI][Medline] [Order article via Infotrieve]



The following articles in journals at HighWire Press have cited this article:


Home page
Clin. Chem.Home page
R. E. Nelson, S. K. Grebe, D. J. O'Kane, and R. J. Singh
Liquid Chromatography-Tandem Mass Spectrometry Assay for Simultaneous Measurement of Estradiol and Estrone in Human Plasma
Clin. Chem., February 1, 2004; 50(2): 373 - 384.
[Abstract] [Full Text] [PDF]


Home page
Clin. Chem.Home page
Z. Cao, T. A. Swift, C. A. West, T. G. Rosano, and R. Rej
Immunoassay of Estradiol: Unanticipated Suppression by Unconjugated Estriol
Clin. Chem., January 1, 2004; 50(1): 160 - 165.
[Abstract] [Full Text] [PDF]


This Article
Right arrow Extract Freely available
Right arrow Full Text (PDF)
Right arrow A correction has been published
Right arrow Submit an electronic Letter to
the Editor about this paper
Right arrow Alert me when this article is cited
Right arrow Alert me when eLetters are posted
Right arrow Alert me if a correction is posted
Right arrow Citation Map
Services
Right arrow Email this article to a friend
Right arrow Similar articles in this journal
Right arrow Similar articles in ISI Web of Science
Right arrow Similar articles in PubMed
Right arrow Alert me to new issues of the journal
Right arrow Download to citation manager
Right arrow reprints & permissions
Citing Articles
Right arrow Citing Articles via HighWire
Right arrow Citing Articles via ISI Web of Science (10)
Right arrow Citing Articles via Google Scholar
Google Scholar
Right arrow Articles by Wu, H.
Right arrow Articles by Aboleneen, H.
Right arrow Search for Related Content
PubMed
Right arrow PubMed Citation
Right arrow Articles by Wu, H.
Right arrow Articles by Aboleneen, H.
Related Collections
Right arrow Endocrinology and Metabolism


HOME HELP FEEDBACK SUBSCRIPTIONS ARCHIVE SEARCH TABLE OF CONTENTS