Clinical Chemistry 53: 1715-a-1716-a, 2007; 10.1373/clinchem.2007.089763
This Article
Right arrow Extract Freely available
Right arrow Full Text (PDF)
Right arrow Submit an electronic Letter to
the Editor about this paper
Right arrow Alert me when this article is cited
Right arrow Alert me when eLetters are posted
Right arrow Alert me if a correction is posted
Services
Right arrow Email this article to a friend
Right arrow Similar articles in this journal
Right arrow Similar articles in ISI Web of Science
Right arrow Similar articles in PubMed
Right arrow Alert me to new issues of the journal
Right arrow Download to citation manager
Right arrow reprints & permissions
Citing Articles
Right arrow Citing Articles via HighWire
Right arrow Citing Articles via ISI Web of Science (1)
Right arrow Citing Articles via Google Scholar
Google Scholar
Right arrow Articles by Krouwer, J. S.
Right arrow Search for Related Content
PubMed
Right arrow PubMed Citation
Right arrow Articles by Krouwer, J. S.
Related Collections
Right arrow Laboratory Management
Right arrow General Clinical Chemistry
Right arrow Informatics and Statistics
(Clinical Chemistry. 2007;53:1715-1716.)
© 2007 American Association for Clinical Chemistry, Inc.


Letters to the Editor

A Recommended Improvement for Specifying and Estimating Serum Creatinine Performance

Jan S. Krouwer

Krouwer Consulting, 26 Parks Drive, Sherborn, MA 01770, Fax 1-508-647-9380, E-mail jan.krouwer{at}comcast.net


To the Editor:

Myers et al. (1) discuss the importance of creatinine analytical performance in the estimation of the glomerular filtration rate. They correctly specify a model of assay performance but subsequently do not seem to use that model. I suggest a variation of their model that is less subject to misinterpretation. The Myers et al. (1) model is:

Formula 1(1)
where Y is a result of a field creatinine assay, bias is the average bias between Y and a reference method for creatinine measurement, and imprecision includes imprecision sources from short-term (within-run or repeatability) and long-term (within-laboratory or reproducibility) and random patient interferences [called specimen-specific effects by Myers et al. (1)]. Here we refer to the 1st 2 sources of imprecision as total imprecision and the last source as random patient interferences.

Although the Myers et al. (1) model is correct, the simulation carried out by Myers et al. is subject to misinterpretation. It is confusing to present the 2 error sources, total imprecision, and random interferences as 1 combined error source, because these 2 error sources are quite different. This confusion seems to have taken place during the preparation of the report, in which the result of a proficiency survey was compared to the simulation. Because neither controls nor pooled samples are used in a proficiency survey, random patient interferences cannot be estimated. Thus, conclusions drawn from this comparison are suspect. Moreover, their alternative way to describe creatinine assay performance goals clearly leaves out random patient interferences [Table 1 in Myers et al. (1)].

The following is suggested as a more useful way to model assay performance:

Formula 2(2)
The only difference between Eq. 2Up and Eq. 1Up is that total imprecision and random patient interferences have been separated. In a previous letter published in Clinical Chemistry (2), we added a 4th term, random biases unrelated to interferences from a specific patient sample. It is simpler, however, to lump this term into total imprecision, which gives the same model described by Lawton et al. (3).

Assay performance goals should account for all 3 terms in Eq. 2Up . In setting these goals, average bias can be set at a low amount because, as stated by Myers et al. (1), manufacturers have a way of achieving low average bias through standardization. Thus, the majority of error can be allocated between imprecision and random patient interferences. Random patient interferences are also a known factor—their expected value would be zero for an assay with perfect analytical specificity—because Myers et al. (1) discuss analytical nonspecificity problems for several types of creatinine assays and recommend improvement, yet do not specify the magnitude of improvement needed. The specific magnitude of improvement needed could be calculated with the 3-term model described above.

Estimates for each of the 3 error sources can be generated by comparing field and reference creatinine measurements with a series of patient samples. Analysis is simplified because the concentration range of interest for glomerular filtration rate estimation is narrow. The average difference and the SD of differences (for which the difference is between the field and reference method for each patient sample) gives the 2 quantities in Eq. 1Up , with total imprecision limited to the time interval of the method comparison experiment. (To ensure that differences are largely due to the field method, the reference method should be replicated to minimize imprecision). If an independent estimate of total imprecision for the field creatinine assay for this time interval is available, the imprecision term from Eq. 1Up can be separated into the 2 components expressed in Eq. 2Up .


Acknowledgments

Grant/funding support: None declared.

Financial disclosures: None declared.


References

  1. Myers GL, Miller WG, Coresh J, Fleming J, Greenberg N, Greene T, et al. Recommendations for improving serum creatinine measurement: a report from the Laboratory Working Group of the National Kidney Disease Education Program. Clin Chem 2006;52:5-18.[Abstract/Free Full Text]
  2. Krouwer JS. How to improve total error modeling by accounting for error sources beyond imprecision and bias. [Letter]Clin Chem 2001;47:1329-1330.[Free Full Text]
  3. Lawton WH, Sylvester EA, Young-Ferraro BJ. Statistical comparison of multiple analytic procedures: application to clinical chemistry. Technometrics 1979;21:397-409.[CrossRef][ISI]



The following articles in journals at HighWire Press have cited this article:


Home page
Clin. Chem.Home page
W. G. Miller, G. L. Myers, and J. H. Eckfeldt
The authors of the article cited above respond:
Clin. Chem., September 1, 2007; 53(9): 1716 - 1717.
[Full Text] [PDF]


This Article
Right arrow Extract Freely available
Right arrow Full Text (PDF)
Right arrow Submit an electronic Letter to
the Editor about this paper
Right arrow Alert me when this article is cited
Right arrow Alert me when eLetters are posted
Right arrow Alert me if a correction is posted
Services
Right arrow Email this article to a friend
Right arrow Similar articles in this journal
Right arrow Similar articles in ISI Web of Science
Right arrow Similar articles in PubMed
Right arrow Alert me to new issues of the journal
Right arrow Download to citation manager
Right arrow reprints & permissions
Citing Articles
Right arrow Citing Articles via HighWire
Right arrow Citing Articles via ISI Web of Science (1)
Right arrow Citing Articles via Google Scholar
Google Scholar
Right arrow Articles by Krouwer, J. S.
Right arrow Search for Related Content
PubMed
Right arrow PubMed Citation
Right arrow Articles by Krouwer, J. S.
Related Collections
Right arrow Laboratory Management
Right arrow General Clinical Chemistry
Right arrow Informatics and Statistics


HOME HELP FEEDBACK SUBSCRIPTIONS ARCHIVE SEARCH TABLE OF CONTENTS